Tisch Environmental TE-5000-BL, TE-5000D Operation Manual

OPERATIONS MANUAL
TE-5000-BL Total Suspended Particulate
High Volume Air Sampler
Tisch Environmental, Inc.
145 South Miami Avenue
Village of Cleves, Ohio 45002
Toll Free: (877) 263 -7610 (TSP AND-PM10)
Direct: (513) 467-9000
FAX: (513) 467-9009
sales@tisch-env.com
www.tisch-env.com
TE-5000-BL TSP 2 Operations Manual
TE-5000-BL TSP
Welcome
We are the experts in high volume air sampling, lead sampling, lead samplers, particulate monitoring, particulate emissions, pesticide monitoring, pesticide sampling, total suspended particles, particulate sampler, Federal Reference Method PM-10, Federal Reference Method PM2.5, EPA Method TO-4A, EPA Method TO-9A, EPA Method TO-13A. TEI is a family business located in the Village of Cleves, Ohio. TEI employs skilled personnel who average over 20 years of experience each in the design, manufacture, and support of air pollution monitoring equipment. Our modern well-equipped factory, quality philosophy and experience have made TEI the supplier of choice for air pollution monitoring equipment. Now working on the fourth generation, TEI has state-of-the-art manufacturing capability and is looking into the future needs of today's environmental professionals.
Assistance
If you encounter problems or require detailed explanations, do not hesitate to contact Tisch Environmental offices by e-mail or phone.
Toll Free: (877) 263 -7610 (TSP AND-PM10) Direct: (513) 467-9000 FAX: (513) 467-9009
sales@tisch-env.com www.tisch-env.com
TE-5000-BL TSP 3 Operations Manual
Table of Contents
Welcome _______________________________________________________________________________ 3
Assistance ______________________________________________________________________________ 3
Introduction _______________________________________________________________________ 6
EPA Standards ___________________________________________________________________________ 6
Safety Precautions _______________________________________________________________________ 6
Important Safety Instructions ______________________________________________________________ 6
Electrical Installation _____________________________________________________________________ 7
Do Not Abuse Cords ______________________________________________________________________ 7
Extension Cords__________________________________________________________________________ 7
Product Description _________________________________________________________________ 8
Introduction ____________________________________________________________________________ 8
Applications ____________________________________________________________________________ 8
Calibration Requirements __________________________________________________________________ 8
Calibration Kits __________________________________________________________________________ 9
Parts _________________________________________________________________________________ 10
Assembly _________________________________________________________________________ 12
Gabled Roof Assembly ___________________________________________________________________ 13
Electrical Set-Up ________________________________________________________________________ 15
Operations ________________________________________________________________________ 16
Calibration Procedure ____________________________________________________________________ 16
Example Problems ______________________________________________________________________ 20
Total Volume ___________________________________________________________________________ 25
Sampler Operation ______________________________________________________________________ 26
Timer Preparation _______________________________________________________________________ 27
Troubleshooting ___________________________________________________________________ 28
Maintenance and Care ______________________________________________________________ 30
Warranty _________________________________________________________________________ 31
Assembly Drawings _________________________________________________________________ 32
TE-5000-BL TSP 4 Operations Manual
TE-5005-BL, Brushless Blower Motor ________________________________________________________ 32
TE-5003 Filter Holder ____________________________________________________________________ 33
Calibration Worksheet ______________________________________________________________ 34
Calibrator Certificate _______________________________________________________________ 35
TE-5000-BL TSP 5 Operations Manual
Introduction
EPA Standards
The following manual will instruct you in the unpacking, assemblage, operation, calibration, and usage of the corresponding Tisch Environmental product. For information on air sampling principles, procedures and requirements and to ensure compliance with government regulations please contact the local Environmental Protection Agency Office serving your area or visit www.epa.gov.
Safety Precautions
Before using Tisch Environmental products, always be sure to review the corresponding operations manuals and take all necessary safety precautions. Tisch Environmental products are to be used only for the purposes specified by operations manuals and by Tisch Environmental personnel. Tisch Environmental cannot guarantee the safe usage of its instruments in procedures that do not adhere to Tisch Environmental guidelines and standards. If you have concerns about the safety of your product or questions about safe practices, contact Tisch Environmental by phone or e-mail to speak with a representative.
Important Safety Instructions
Read and understand all instructions. Do not dispose of these instructions. Failure to follow all instruction listed in this manual may result in electric shock, fire, and/or personal injury. When using an electrical device, basic precautions must always be followed, including the precautions listed in the safety section of this manual. Never operate this unit in the presence of flammable materials or vapors are present as electrical devices may produce arcs or sparks that can cause fire or explosions. Always disconnect power supply before attempting to service or remove any components. Never immerse electrical parts in water or any other liquid. Always avoid body contact with grounded surfaces when plugging or unplugging this device is wet or dangerous conditions.
TE-5000-BL TSP 6 Operations Manual
Electrical Installation
Installation must be carried out by specialized personal only, and must adhere to all local safety rules. This unit can be used for different power supply versions; before connecting this unit to the power line, always check if the voltage shown on the serial number tag corresponds to the one on your power supply. This product does use grounded plugs and wires. Grounding provides the path of least resistance for electrical currents, thereby reducing the risk of electric shock to users. This system is equipped with electrical cords with internal ground wires and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided. If plug will not fit outlet, have the proper corresponding outlet installed by a professional, qualified electrician.
Do Not Abuse Cords
In the event that any electrical component of this system needs to be transported, DO NOT carry the unit by its power cord or unplug the unit by yanking the cord from the outlet. Pull the plugs, not the cords, to reduce risk of damage to unit. Keep all cords away from heat, oil, sharp objects, and moving parts.
Extension Cords
It is always advisable to use the shortest extension cord possible. Grounded units require a three-wire extension cord. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wires results in serious changes in voltage, resulting in a loss of power and possible damage to equipment. It is recommended to only use 10-gauge extension cords for this product. Never use cords that exceed one hundred feet. Outdoor extension cords must be marked with the suffix “W-A” (or “W” in Canada)to indicate that it is suitable for outdoor usage. Always ensure that extension cords are properly wired and in good electrical condition. Always replace damaged extension cords immediately, or seek repair from qualified electricians before further use. Remember to protect extension cords from sharp objects, excessive heat, and damp or wet conditions.
TE-5000-BL TSP 7 Operations Manual
Product Description
Introduction
The High Volume Air Sampler (also known as a lead sampler) is the recommended instrument for sampling large volumes of air for the collection of TSP (Total Suspended Particulate). The physical design of the sampler is based on aerodynamic principles that result in the collection of particles of 100 microns (Stokes Equivalent Diameter) and less. The TE-5000-BL TSP sampler consists of a TE-5001 Anodized Aluminum Shelter, TE-5001-10 Gabled Roof Assembly, TE-5005-BL Brushless Blower Motor Assembly, TE-5003 8”x10” Stainless Steel Filter Holder, TE-5009 Continuous flow/pressure recorder, TE-106 Box of Charts, TE-5010 voltage variator/elapsed time indicator, and TE-5007 Mechanical Timer.
Applications
Ambient air monitoring to determine suspended particulate levels relative to air
quality standards.
Impact of a specific source on ambient levels of suspended particulates by
incorporating a "wind-direction-activation" modification which permits the sampler to operate only when conditions are such that a source-receptor relationship exists.
Monitoring of enclosed environments for relatively high levels of particulate
matter, particularly toxic materials.
Monitoring of emissions from large diameter vents where physical conditions
preclude the use of conventional stack-testing equipment.
Calibration Requirements
TE-5000-BL TSP MFC High Volume Air Sampler should be calibrated:
Upon installation After any motor maintenance Once every quarter (three months) After 360 sampling hours
TE-5000-BL TSP 8 Operations Manual
Calibration Kits
The TE-5028 is the latest calibration kit available for use with the TE-5000-BL TSP High Volume Air Sampler.
The TE-5028 is the preferred method to calibrate the TE-5000-BL TSP High Volume Air Sampler. It simulates change in the resistance by merely rotating the knob on the top of the calibrator. The infinite resolution lets the technician select the desired flow resistance. The TE-5028 calibration kit includes: carrying case, 30” slack tube water manometer, adapter plate, 3’ piece of tubing, and TE-5028A orifice with flow calibration certificate. Optional electronic manometer is available.
Each TE-5028A is individually calibrated on a primary standard positive displacement device (Rootsmeter) which is directly traceable to NIST.
** It is recommended by the EPA that each calibrator should be re-calibrated annually for accuracy and reliability.
TE-5000-BL TSP 9 Operations Manual
Sampler System
TE-5000BLX 110volt, 60hz TE-5000BLX 220volt, 50hz TE-5000BLXZ-220volt, 60hz
7-Day Mechanical Timer
TE-5007 110volt, 60hz TE-5007X 220volt, 50hz TE-5007XZ 220volt, 60hz
Continuous Flow Recorder
TE-5009 110volt, 60hz TE-5009X 220volt, 50hz TE-5009XZ 220volt, 60hz
Motor Voltage Control
TE-5010 110volt, 60hz TE-5010X 220volt, 50hz TE-5010XZ 220volt, 60hz
Blower Motor Assembly with Tubing
TE-5005-BL 110volt TE-5005X-BL 220volt
Parts
1. Shelter Box – 46” x 20” x 23”, 72lbs
TE-5000-BL TSP 10 Operations Manual
8” x 10” TSP Stainless Steel Filter Holder
TE-5003
Filter Holder Gasket
TE-5005-9
Envelope box of charts and manual
TE-106
Gabled Roof
TE-5001-10
2. Lid Box - 19" x 14" x 14" 9 lbs
*** Save the shipping containers and packing material for future use.
TE-5000-BL TSP 11 Operations Manual
Loading...
+ 24 hidden pages