Tim Sistem NIKA- HYDRO Owner's Manual

NIKA- HYDRO Fireplace stove on solid fuel
Owners’s manual
INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION
Dear Customer,
We appreciate your trust wested in us and decision to use "TIM SISTEM" product. You have invested in energy-efficient and high-quality product – NIKA HYDRO wood burning
stove. Your purchase will provide you long-term clean and comfortable heating with minimal
maintenance. Please read these instructions carefully and completely. The purpose of the manual is to inform you about the installation, operation and maintenance
of your stove. Keep it handy and refer to it as needed. You will find in it information that will be useful now and in the years to come.
Make sure that when installing the stowe all security standards have been respected and that all gas pipes, connections between tubes and pipes and walls are connected properly.
Disregarding these standards and negligence during installation can result in damaging your property or put your health and life in danger !
Set your stove to a safe place, away from the frequent passages and doors, somewhere near chimney and chimney connection.
We wish you many pleasant moments with NIKA HYDRO.
TIM SISTEM d.o.o.
CONTENTS
WARNING BEFORE USE ............................................................................ Error! Bookmark not defined.
DECRIPTION OF THE STOVE ...................................................................... Error! Bookmark not defined.
INSTALLING THE STOVE ............................................................................ Error! Bookmark not defined.
IGNITION AND LIGHTING .......................................................................... Error! Bookmark not defined.
HANDLING THE STOVE OPERATION ......................................................... Error! Bookmark not defined.
I –authomatic ragulation of stove operation (regulation of primar air) ............. Error! Bookmark not
defined.
II – regulation of secundary air ............................................................ Error! Bookmark not defined.
INSTALLING THE STOVE INTO THE SYSTEM FOR WATER HEATING .......... Error! Bookmark not defined.
Installaion on closed central heating system ....................................... Error! Bookmark not defined.
Installaion on opened central heating system ..................................... Error! Bookmark not defined.
CLEANING AND MAINTENANCE ............................................................... Error! Bookmark not defined.
MALFUNCTION. RECOMENDATION FOR ITS ELIMINATION ..................... Error! Bookmark not defined.
GENERAL RECOMMANDATION ................................................................ Error! Bookmark not defined.
ADVICES FOR ENVIROMENT PROTECTION ............................................... Error! Bookmark not defined.
Packaging .............................................................................................. Error! Bookmark not defined.
Product ................................................................................................. Error! Bookmark not defined.
WARRANTY ............................................................................................... Error! Bookmark not defined.
WARNING BEFORE USE
To keep your stove working properly, it is important to read this manual and strictly stick to the instructions for use and handling.
For combustion use solid fuels such as wood and wood briquettes. It is forbidden putting explosive devices and materials combustion chamber or the limited thermal furnace. It is forbidden to keep flammable materials near the stove.
For proper combustion, in normal operating mode, draft in the chimney should be 10-12PA. If the draft is greater than 15Pa, the valve should be installed in the chimney.
Room where the stove is positioned must be vented regularly for the fresh air needed for combustion.
Some parts of stove heat up during operation and it takes appropriate precaution when handling it. Do not allow children to handle and play near the stove.
Only spare partes reccomended and allowed by the manufacturer should be installed on the stove . You must not make any changes on the stove.
With first firing there might show a mild smoke, especially from the plate’s surface. It is a common appearance that occurs due to combustion deposits on the plate’s surface
(corrosion protection, paint, dust, ....). The room where the stove should be vented during the
first firing. It’s not reccomended connecting the stove to the common chimney because it can adversely
affect the required draft. Device that uses gas as fuel must not be connected to same chimney. During firing, use protection gloves because the door handles get heated. National and local regulations for the installation of the furnace must be respected.
In a case of diregarding instructions given in this manual, manufacturer does not take any kind of responsability for caused damage.
DESCRIPTION OF THE STOVE
NIKA HYDRO storey stove is manufactured and tested according to European standard EN 13240.
On the figure 1 is shown the appearance of the stove with all it's components important for
handling.
NIKA HYDRO fireplace stove has a boiler (figure 1, position 11), 12.5 l volume made of boiler
tin-plates, tickness prescribed by standards. This kind of manufacture prolongs life of the boiler. Water connections are 1.
The upper plate of the fireplace is made of steal (figure 1, position 1) Firebox doors (figure 1, position 4) are made of cast iron with fireproof glass. Connection for smoke drain (figure 1, position 2) is made of cast iron and it’s installed on the
plate with 2 screws. All the materials that the stove is made of can be recycled. Sealing elements are made of materials that doesn’t contain asbestos. Grid in the firebox (figure 1, position 10) is made of cast iron.
Parts of the stove:
1. Upper plate
2. Smoke drain
3. Secondary air regulator
4. Firebox door
5. Firebox door handle
6. Glass
7. Ashtray
8. Authomatic regulator
9. Lever
10. Grid
11. Boiler
TECHNICAL DATA
Name NIKA HYDRO
Use Solid fuel sorey stove
Nominal power
kW
20
Efficiency
%
Fuel
84
Dimensions of the stove WxLxH
mm
705 x 441 x 760
Dimensions of the firebox WxLxH
mm
574 x 260 x 280
Weight
kg
153
Minimum distance from flammable materials
Back
mm
500
Lateral
mm
500
Front
mm
800
Content of CO (reduced on 13% O2)
%
Wood
0,091
Emission of CO(reduced on 13% O2)
Chimney connection
mm
Ø150
Chimney connection position
Central on upper plate
Consuption by nominal power
kg/h
2,65
Emission temperature
°C
241
Air regulation
Primary
Automatski (Rathgeber)
Secundary Manual
Required amount of water in the boiler
l
12,5
Required draft
Pa
12-15
Storey stove is made for heating of residential premises. An integral part of the installation is thermal drain valve that serves as a thermal fuse of a possible overheating. The recommended thermal fuse is Caleffi 1/2 544, shown in Figure 2.
Note: The thermal fuse is not part of the product and it's not supplied with the product. The guarantee is valid only if the termar fuse gets installed into the boiler.
Figure 2. Thermal fuse Caleffi
INSTALLING THE COOKER
The stove must not be set up near the wooden parts, refrigeration elements, plastic furniture and other flammable materials because during operation (during fuel combustion) it achieves high operating temperature that is distributed on the outside of the furnace. Minimum distance between the stove and the surrounding elements is 50 cm, and the from flamable materials 80 cm.
If the ground on which you set the stove is made of easily flammable material (wood, warm
floor, laminate ...) you need to set under the stove a protetion sheet metal - lateral width of 10 cm and 50 cm in the front.
Because of it’s weight, the stove must be installed on the appropriate base. If it does not satisfie necessary standard, you must take appropriate measures to make it possible (eg, weight distribution).
Connect the fireplace stove to a chimney and flue pipes through the connector on top of the furnace, so as to ensure adequate tightness and flow of smoke from the stove to the chimney. Flue pipe must not be drawn too deeply into the chimney that would reduce the cross sectional area and thus undermined draft in the chimney. Do not use reducers which reduce the cross section of pipe smoke.
The stove requires insertion of fresh air in the room where it is installed, with surface openings for insertion of fresh air should not be less than 0.4 dm ². The unit for fresh air set outside the common room for ventilation, which must be insured by door and gride.
Fans that work in the same room where the cooker is installed may make interference wit the the cooker. Also, all devices or ventilation that creates negative pressure in the room where the cooker is installed, must be set in the way that does not make decompression that prevents normal operation of the stove.
Before installing the stove, check the chimney drafts because it is a key factor in the proper functioning of the stove. Draft depends on the proper opration of the chimney and meteorological conditions. One of the easiest ways to check the draft in the chimney is with a candle flame, as shown in Figure 3 . Put a candle near the chimney connection drain. If the flame bends towards drain, the draft is satisfying (Figure 3b). If the flame doesn’t bend or bends a little, that indicates poor draft(Figure 3a).
If there is poor draft in the chimney (Figure 3a), check the chimney functioning. The chimney should be located inside the building, and if it’s located on the external walls of the building,
it’s highly recommended insulation of the chimney.
Disadvantages of the chimney (Figure 4): `
1.
The chimney is lower the top of the roof, a small cross section of the output.
2.
Excessive slope
3.
A sudden change of direction of the channel
4.
Stove or some other evice is connected to the same flue channel
5.
Bulges in the channel
6.
Cracks
7.
Alien body or acumulated grime
8.
Tube inserted to deeply
9.
Fan or other device that creates a vacum in the room
10.
Unseald or opened cleaning hole