NIKA
Owners’s manual
INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION
EN 13240
![](/html/ed/ed16/ed16904e61516b42058833cad99d39076323d05b401910abaec7877a23b58cd4/bg2.png)
Dear Customer,
We appreciate your trust wested in us and decision to use "TIM SISTEM" product.
You have invested in energy-efficient and high-quality product - NIKA wood burning stove.
Your purchase will provide you long-term clean and comfortable heating with minimal
maintenance.
Please read these instructions carefully and completely.
It’s purpose is to inform you about the installation, operation and maintenance of your stove.
Keep it handy and refer to it as needed. You will find in it information that will be useful now
and in the years to come.
Make sure that when installing the stowe all security standards have been respected and
that all gas pipes, connections between tubes and pipes and walls are connected properly.
Failure to comply with these standards and carelessness during installation can result in
damage to property or put your health and life in danger !
Set your stove to a safe place, away from the frequent passages and doors, somewhere
near chimney and chimney connection.
We wish you many pleasant moments with NIKA.
TIM SISTEM d.o.o.
![](/html/ed/ed16/ed16904e61516b42058833cad99d39076323d05b401910abaec7877a23b58cd4/bg3.png)
WARNING BEFORE USE
To keep your stove working properly, it is important to read this manual and strictly stick to
the instructions for use and handling.
For combustion use solid fuels such as wood and wood briquettes. It is forbidden putting
explosive devices and materials combustion chamber or the limited thermal furnace. It is
forbidden to keep flammable materials near the stove.
For proper combustion, in normal operating mode, draft in the chimney should be 10-12PA. If
the draft is greater than 15Pa, the valve should be installed in the chimney.
Room where the stove is positioned must be vented regularly for the fresh air needed for
combustion.
Some parts of stove heat up during operation and it takes appropriate precaution when
handling it. Do not allow children to handle and play near the stove.
Only spare partes reccomended and allowed by the manufacturer should be installed on the
stove . You must not make any changes on the stove.
With first firing there might show a mild smoke, especially from the plate’s surface. It is a
common appearance that occurs due to combustion deposits on the plate’s surface
(corrosion protection, paint, dust, ....). The room where the stove should be vented during the
first firing.
It’s not reccomended connecting the stove to the common chimney because it can adversely
affect the required draft.
Device that uses gas as fuel must not be connected to same chimney.
During firing, use protection gloves because the door handles get heated.
National and local regulations for the installation of the furnace must be respected.
In a case of non-copliance with instructions given in this manual, manufacturer does
not take any kind of responsability for caused damage.
![](/html/ed/ed16/ed16904e61516b42058833cad99d39076323d05b401910abaec7877a23b58cd4/bg4.png)
DESCRIPTION OF THE STOVE
NIKA wood burning stove is used for heating rooms and it’s manufactured and tested
according to European standard EN 13240.
The upper plate of the fireplace is made of steal.
Firebox doors are made of cast iron with fireproof glass.
Connection for smoke drain is being put on the plate and connected with screws.
All the materials that Nika stove is made can be recycled.
Sealing elements are made of materials that contain asbestos.
Parts of the stove:
1. Firebox doors
2. Primary air regulator
3. Secondary air regulator
4. Upper plate
5. Smoke drain
6. Lever
7. Glass
8. Grid carrier
9. Grid
![](/html/ed/ed16/ed16904e61516b42058833cad99d39076323d05b401910abaec7877a23b58cd4/bg5.png)
Dimensions of the stove WxLxH
Dimensions of the fire place WxLxH
Minimum distance from flammable materials
Content CO (reduced on 13% O2)
Chimney connection position
Consuption by nominal power