Tim Sistem CAROBNA HYDRO Owner's Manual

CAROBNA HYDRO
Owners’s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION
EN 13240
1
Dear Customer,
We appreciate your trust on our product and decision to use "TIM SISTEM" product. You have invested in energy-efficient and high-quality product – CAROBNA HYDRO wood burning
stove. Your purchase will provide you long-term clean and comfortable heating with minimal maintenance. Please read these instructions carefully and completely. Its purpose is to inform you about the installation, operation and maintenance of your stove. Keep it
handy and refer to it as needed. You will find in it information that will be useful now and in the years to come.
Make sure that when installing the stove all security standards have been respected and that all water pipes, connections between tubes and pipes and walls are connected properly.
Failure to comply with these standards and carelessness during installation can result in damage to property or put your health and life in danger!
Set your stove to a safe place, away from the frequent passages and doors, somewhere near chimney and chimney connection.
We wish you many pleasant moments with CAROBNA HYDRO.
TIM SISTEM d.o.o.
CAROBNA HYDRO 2/ 20
Table of contents
WARNING BEFORE USE ......................................................................................................................................... 3
DESCRIPTION OF STOVE ........................................................................................................................................ 4
INSTALING THE STOVE .......................................................................................................................................... 6
IGNITION AND LIGHTING ...................................................................................................................................... 8
HANDLING STOVE OPERATION ............................................................................................................................ 9
I - regulation of secondary air ......................................................................................................................... 10
INSTALATION OF STOVE IN SYSTEM FOR CENTRAL HEATING ............................................................................. 10
Instalation on closed central heating system ................................................................................................. 11
InatLtion on the open central system ............................................................................................................. 12
CLEANING AND MEINTENANCE .......................................................................................................................... 13
MALFUNCTION - RECOMMENDATION FOR ITS SLIMINATION............................................................................ 14
GENERAL RECOMENDATION ............................................................................................................................... 14
ADVICES FOR ENVIROMENT PROTECTION .......................................................................................................... 15
Packaging ........................................................................................................................................................ 15
Product ............................................................................................................................................................ 15
DECLERATION OF GUARANTEE .............................................................................. Error! Bookmark not defined.
CAROBNA HYDRO 3/ 20
WARNING BEFORE USE
To keep your stove working properly, it is important to read this manual and strictly stick to the
instructions for use and handling.
For combustion use solid fuels such as wood and wood briquettes. It is forbidden putting explosive devices
and materials combustion chamber or the limited thermal furnace. It is forbidden to keep flammable
materials near the stove.
For proper combustion, in normal operating mode, draft in the chimney should be 12-15PA. If the draft is
greater than 17Pa, the valve should be installed in the chimney.
Room where the stove is positioned must be vented regularly for the fresh air needed for combustion.
Some parts of stove heat up during operation and it takes appropriate precaution when handling it. Do not
allow children to handle and play near the stove.
Only spare parts recommended and allowed by the manufacturer should be installed on the stove. You
must not make any changes on the stove.
With first firing there might show a mild smoke, especially from the plate’s surface. It is a common
appearance that occurs due to combustion deposits on the plate’s surface(corrosion protection, paint,
dust, ....). The room where the stove is should be vented during the first firing.
It’s not recommended connecting the stove to the common chimney because it can adversely affect the
required draft.
Device that uses gas as fuel must not be connected to same chimney.
During firing, use protection gloves because the door handles get heated.
National and local regulations for the installation of the furnace must be respected.
In a case of non-compliance with instructions given in this manual, manufacturer does not take any kind of
responsibility for caused damage.
CAROBNA HYDRO 4/ 20
DESCRIPTION OF STOVE
Wood burning stove CAROBNA HYDRO is manufactured and tested according to European standard EN
13240. Figure 1 shows the layout of the stove with integral parts essential for handling. Wood burning stove CAROBNA HYDRO has a boiler (fig. 1, pos. 11) capacity of 10l, which is made of boiler plate thickness prescribed standards. Such preparation increases the working life of the boiler. Connections for water are 1“. The upper plate of the fireplace is made of steel. (fig. 1, pos. 1) Firebox doors (fig. 1, pos. 6) are made of steel with fireproof glass. Connection for smoke drains being put on the plate and connected with screws. (fig. 1, pos 2.). and are made of cast iron All the materials that CAROBNA HYDRO stove is made can be recycled. Sealing elements are made of materials that NOT contain asbestos. The grid in the combustion chamber (fig. 1, pos. 8) is made of cast iron.
Integral parts of the stove:
1 –Upper (hot) plate 2 – Smoke exhaust 3 – Secondary air regulator 4 – Secondary air 5 – Door handle 6 – Fire door feat resistant glass 7 – Grid carrier 8 – Grid 9 – Primary air regulator 10 - Ash pan 11 - Boiler
Fig. 1. integral parts of the stove CAROBNA HYDRO
CAROBNA HYDRO 5/ 20
Technical data:
Name
ČAROBNA HYDRO
Use
Fireplace stove for heating
with integrated boiler
Nominal power [kW]
13,16
Nominal power given to water
7,12
Space heat output
6,04
Efficiency [%]
81,25
Fuel
Wood, wood briquettes
Dimensions of stove WxLxH [mm]
430x464x823
Dimension of the fireplace WxLxH [mm]
340x300x285
Weight [kg]
110
Minimum distance from flammable materials [mm]
Back
500
Side
500
Front
800
Content CO (reduced on 13% O2) [%]
0,091
Chimney connection [mm]
Ø120
Chimney connection position
Central on upper plate
Fuel consumption on nominal power [kg/h]
4,5
Emission temperature [°C]
247
Air regulation Primary
Manual control
Secondary
Manual control
Boiler water capacity [l]
10
Required draft [Pa]
12-15
Hydro stove with back boiler are intended for heating residential space. An integral part of the installation is a temperature safety relief valve for thermal discharge that serves as thermo safety of possible overheating. It is recommended Caleffi 544 ½” shown in Figure 2
Fig 2.
Function:
Drain valve for thermal protection limits the water temperature. They are intended for cooling of heating hot water when the temperature reaches the limit of 95 C. If the probe is immersed in the hot water outlet from the boiler registers the increase in temperature gives a signal to open the valve to the cold water from the local installation introduced into the system and cools it until the excess hot water goes to the drain.
They are intended for installation in systems where it is not possible to install the valve directly to the boiler body (not exist without heat exchanger)
Loading...
+ 14 hidden pages