INSTRUCTION
SH OW ER C AB IN I LM A 90 1
Leak-protection
switch works
Smoke comes
from steam
output, or bad
smell
Get an electric
shock, but the
leak-protection
switch doesn’t
work.
26
3. The signal wire between the Electric Box and Steam Generator doesn’t connect
well. (Connect it)
4. The wire of the heater between Electric Box and Steam Generator doesn’t
connect well. (Connect it )
5. Anti-dry heating protection works. (Restore)
6. The water inlet valve is broken ( Replace it)
7. Steam Generator or Electric Box is broken. (Replace it)
1. Leakage of the AC220V power supply. ( Bind it)
2. Leakage of the heater inside the steam generator. ( Replace it )
3. The leak -protection switch is not good. ( Replace it )
1. Inside the Steam Generator, the water level wire is in short circuit or there is
water in the level sensor.
( Debug the short circuit and dry the level sensor)
2. Steam Generator or Electric Box is broken. (Replace it)
The ground wire doesn’t connect well. (Please make sure that the ground wire of
the shower room connect the ground well)
8. Special Declaration:
When this product needs repair, please contact the qualified technician from dealer, otherwise
it will be not free.