TIMO ILMA 701, ILMA 709 User guide

ILMA 709 / ILMA 701
switch works
Smoke comes
from steam
output, or bad
smell
Get an electric
shock, but the
leak-protection
switch doesn’t
work.
pag e
27
3. The signal wire between the Electric Box and Steam Generator doesn’t connect
well. (Connect it)
4. The wire of the heater between Electric Box and Steam Generator doesn’t
connect well. (Connect it )
5. Anti-dry heating protection works. (Restore)
6. The water inlet valve is broken ( Replace it)
7. Steam Generator or Electric Box is broken. (Replace it)
1. Leakage of the AC220V power supply. ( Bind it)
2. Leakage of the heater inside the steam generator. ( Replace it )
3. The leak -protection switch is not good. ( Replace it )
1. Inside the Steam Generator, the water level wire is in short circuit or there is
water in the level sensor.
( Debug the short circuit and dry the level sensor)
2. Steam Generator or Electric Box is broken. (Replace it)
The ground wire doesn’t connect well. (Please make sure that the ground wire of
the shower room connect the ground well)
8. Special Declaration:
When this product needs repair, please contact the qualified technician from dealer, otherwise
it will be not free.
5.10. In hard water area, please make descaling rinsing regularly for the steam generator,
especially for the probe of the water level sensor. Normally, check it every three months.
Following descaling rinsing method is ad vised: Use 5-10g citric acid to dilute by 1.4L warm water,
disassemble the pipe of steam output, and infuse the diluted citric acid into the input of steam
generator, then connect the pipe and wait for 60minutes to start the system, after heating for
30minutes to stop and make completely discharge.
5.11. Make sure that all the wires are well connected, output can’t be short circuit with each
other.
5.12. After used this product, please cut off the power supply to avoid long time machine internal
electrification and accelerate ageing.
5.13. The installation of this controller system must follow the instruction and be installed by
qualified technician. If user disobey above operation regulation and cause any adverse
consequence, our company won ’t take any responsibility.
6. Malfunction Analysis :
During the operation of this product, if any abnormal malfunctions happen, please ask qualified
technician to refer following analysis to remove malfunctions.
Malfunctions
Analysis (Solutions)
Type
Can’t turn on the
system, no
display on the
screen
1. No power connection (Connect power supply)
2. Leak -protection switch is off ( Please turn it on), wrong connection inside the
electric box ( Modif y it)
3. Panel doesn’t connect properly. (Connect it well)
4. Pan el or Electric Box is broken. (Replace it)
1. Output of the Light is in open circuit. ( T ighten it )
Light doesn’t
work
2. Output of the Light is in short circuit. (Debug short circuit)
3. Light is broken ( Replace it)
4. The connection between Light and Electric Box is loose. ( T ighten it)
Steam engine
Normal phenomenon.
spray water, and
have steam
Water inlet is
running without
stopping, spout a
lot of water, but
no steam comes
1. The water level sensor loosens. (Tighten it)
2. The water inlet valve is broken. ( Replace it)
3. Steam Generator or Electric Box is broken. (Replace it)
out.
No steam comes
out from steam
generator
1. The Electric Heater inside the Steam Generator is broken. (Replace it)
2. The signal wire of the water inlet valve inside the Steam Generator is off or in
open circuit.(Connect it)