Time Mark 409D Data Sheet

TIME MARK is a division of
MODEL 409D
Liquid Level
Controller
Automatic control of liquid level Solid-state sensing circuit
Adjustable sensitivity 5-Year Unconditional Warranty
DESCRIPTION
The Model 409D is a compact, socket-mount device for
level control of conductive liquids. The internal relay is energized when operating power is applied. When the
liquid level reaches the probe, the relay de-energizes. When the level drops below the probe, the relay will
reset. A fixed, 300 millisecond time delay prevents oscillation due to wave action. Probe cables may be shielded or unshielded. If the liquid container is made of
a non-conductive material, a common electrode is
required. Other features include an LED indicator to show the output relay status and an adjustable
sensitivity setting. Requires a standard 11-pin octal socket (such as the Time Mark model 51X016).
DIMENSIONS
TOP VIEW
FRONT VIEW
SPECIFICATIONS
Model 409D
Operating voltages
Power consumption 2.5W Transient Protection 2500VRMS for 10ms Probe voltage
(open circuit) Probe current 5mA maximum Sensitivity adjust 1K ohms-100K ohms Contacts DPDT Contact Rating 7.5A @ 240 VAC resistive
Expected Relay Life Response Time 300ms
Reset Time <1 second Reset Method Automatic Time delay accuracy ±5% Operating Temp - 2to 60° C Humidity Tolerance 0-97% w/o condensation Case Material NORYL Mounting 11-Pin Socket ( **sold separately) Weight 4.5 oz. Max.
24 VAC: 20-30 VAC, 50-400 Hz 120 VAC: 90-140 VAC, 50-400 Hz 230 VAC: 200-250 VAC, 50-400 Hz
15 VRMS
Mech: 10,000,000 operations
Elec: 100,000 at rated load
** Order 11-pin socket number 51X016
11440 East Pi n e S t r e e t
Tulsa, O k l a h o m a 7 4 1 1 6
© 2017 TIME MARK CORPORATION
MODEL 409D
TIME MARK is a division of
Liquid Level Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 409D.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation Instructions
INSTALLATION
Mount the 11-pin socket in a suitable enclosure. A NEMA-1 rated enclosure, designed for socket-mounted relays, is available from Time Mark (part no. 980498).
Referring to the pin diagram on this page or on the unit connect appropriate AC operating power. Connect the probes as needed, and connect the output relay as
appropriate.
CO M
PR OB E
ADJUSTMENT
Adjust the sensitivity as needed.
WARRANTY
This product is warranted to be free from defects in materials and workmanship, and is covered by our
exclusive 5-year Unconditional Warranty. Should this
device fail to operate for any reason, we will repair it for five years from the date of manufacture. For complete warranty details, see the Terms and Conditions of Sales page in the front section of the Time Mark catalog or
contact Time Mark at 1-800-862-2875. .
TYPICAL APPLICATION
11440 East Pi n e S t r e e t
Tulsa, O k l a h o m a 7 4 1 1 6
© 2017 TIME MARK CORPORATION