⚫ DPDT Digital or knob-adjust versions
⚫ Wide variety of voltage and timing ranges
⚫ 5-year unconditional warranty
DESCRIPTION
The Models 332 and 362 Interval Timers are designed for
a wide usage in new or replacement industrial applications.
Examples include automatic and batch control circuits,
where the relay needs to be energized for a specific length
of time after start-up.
The Model 332 is a DPDT potentiometer (knob-adjust)
timer. The Model 362 is a DPDT, high-accuracy digital
input timer. Solid-state timing circuits in each model drive
an internal electromechanical relay.
Each model is functionally interchangeable. They are
available in a variety of voltage and timing ranges to cover
most any application.
An “SG” version of this model is available using silver with
gold flash contacts.
Models 332 and 362 are UL Recognized and CSA
Certified.
UL SPECIFICATIONS*
Models 332 and 362
Input
Voltage (VAC)
Power 3 Watts Max
Output
10-28V AC/DC OR 40-260V AC/DC
240V AC, 10A, Resistive
120V AC, 4A, General Use
240V AC, 2A, General Use
* Pilot Duty: 120V: Make 15A, Break 1.5A240V: Make 7.5A, Break 0.75A
C300, Pilot Duty
SPECIFICATIONS
MODEL 332 (knob adj.) 362 (digital)
Voltage L = 10-28V AC/DC
Timing range
Accuracy
Repeatability ± 2% ± 0.1%
Recycle time
Operating temp -20°F to +140°F
Contacts DPDT
Contact rating 10A at 240VAC resistive
Transient protection 775V, 80 Joules
Humidity tolerance
Enclosure material NORYL Plastic
Mounting 8-pin socket (not included)**
Weight 5 oz.
Agency approval *UL Recognized and CSA Certified
Ordering Examples (Model-Voltage-Timing Range [/Options]):
362-H-0.1SEC = Model 362 with a 40-260V AC/DC voltage range
and a timing range of 0.1-102.3 seconds.
332-L-180SEC /SG = Model 332 with a 10-28V AC/DC voltage
range, a timing range of 1-180 seconds, and optional silver with gold
flash contacts.
Contact Time Mark to order a custom programmed unit
10SEC: 1 - 10 Sec.
60SEC: 1 - 60 Sec.
180SEC: 1 - 180 Sec.
300SEC: 1 - 300 Sec.
H = 40-260V AC/DC
0.1SEC: 0.1 - 102.3 Sec.
1SEC: 1 - 1023 Sec.
1MIN: 1 - 1023 Min.
1HR: 1 - 1023 Hr.
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 332 OR 362.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation Instructions
ADJUSTMENT PROCEDURE - Model 362
The procedure to determine the switch selections for the
digital Model 362 Interval Timer requires some simple
calculations, which can be completed easily after the basic
steps are explained.
1. Convert the delay time required to minutes, seconds,
2. To set the desired delay period on the timer, just add
the values of the selected dip switches (beginning
with the largest value first) to total the desired time.
e.g. #1: 100 seconds with a 1 second increment
64+32+4 = 100 seconds
e.g. #2: 100 seconds with a .1 second increment
512+256+128+64+32+8 = 1000 tenths of a seconds
WARRANTY
This product is warranted to be free from defects in
materials and workmanship, and is covered by our
exclusive 5-year Unconditional Warranty. Should this
device fail to operate for any reason, we will repair it for
five years from the date of manufacture. For complete
warranty details, see the Terms and Conditions of Sales
page in the front section of the Time Mark catalog or