Time Mark 332, 362 Data Sheet

Page 1
TIME MARK is a division of
MODEL 332
MODEL 362
Interval Timer
DPDT Digital or knob-adjust versions Wide variety of voltage and timing ranges 5-year unconditional warranty
DESCRIPTION
The Models 332 and 362 Interval Timers are designed for a wide usage in new or replacement industrial applications. Examples include automatic and batch control circuits, where the relay needs to be energized for a specific length
of time after start-up. The Model 332 is a DPDT potentiometer (knob-adjust)
timer. The Model 362 is a DPDT, high-accuracy digital input timer. Solid-state timing circuits in each model drive an internal electromechanical relay.
Each model is functionally interchangeable. They are available in a variety of voltage and timing ranges to cover
most any application.
An SGversion of this model is available using silver with
gold flash contacts.
Models 332 and 362 are UL Recognized and CSA
Certified.
UL SPECIFICATIONS*
Models 332 and 362
Input
Voltage (VAC) Power 3 Watts Max
Output
10-28V AC/DC OR 40-260V AC/DC
240V AC, 10A, Resistive 120V AC, 4A, General Use 240V AC, 2A, General Use
* Pilot Duty: 120V: Make 15A, Break 1.5A 240V: Make 7.5A, Break 0.75A
C300, Pilot Duty
SPECIFICATIONS
MODEL 332 (knob adj.) 362 (digital)
Voltage L = 10-28V AC/DC
Timing range
Accuracy Repeatability ± 2% ± 0.1% Recycle time Operating temp -20°F to +140°F Contacts DPDT Contact rating 10A at 240VAC resistive Transient protection 775V, 80 Joules Humidity tolerance Enclosure material NORYL Plastic Mounting 8-pin socket (not included)** Weight 5 oz. Agency approval *UL Recognized and CSA Certified
Additional Options /C = Custom (Voltage and/or Timing)
Ordering Examples (Model-Voltage-Timing Range [/Options]): 362-H-0.1SEC = Model 362 with a 40-260V AC/DC voltage range
and a timing range of 0.1-102.3 seconds. 332-L-180SEC /SG = Model 332 with a 10-28V AC/DC voltage range, a timing range of 1-180 seconds, and optional silver with gold flash contacts.
Contact Time Mark to order a custom programmed unit
10SEC: 1 - 10 Sec. 60SEC: 1 - 60 Sec. 180SEC: 1 - 180 Sec. 300SEC: 1 - 300 Sec.
H = 40-260V AC/DC
0.1SEC: 0.1 - 102.3 Sec. 1SEC: 1 - 1023 Sec. 1MIN: 1 - 1023 Min. 1HR: 1 - 1023 Hr.
± 5% ± 2%
100ms
0 - 97% w/o condensation
/SG = Silver with Gold Flash Contacts
** order 8 -pin socket number 51X120
11440 East P i n e Str e e t
Tuls a , O klahom a 7 4116
Page 1 of 3 02/2020
© 2020 TIME MARK CORPORATION
Page 2
MODEL 332 / 362
TIME MARK is a division of
Delay
Contact
Supply Voltage
Interval Timer
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 332 OR 362.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation Instructions
OPERATION
The internal relay energizes immediately on application of the supply voltage. Upon completion of the delay period,
the relay de-energizes. The supply voltage must be removed to reset the timer.
PIN DIAGRAM
The Models 332 and 362 Interval Timers require a
standard 8-pin socket for mounting, and use a standard
pin configuration. Refer to the pin diagram below, or on
the timer, for terminal connections.
An LED on top of the unit provides a
quick visual indicator of the relays status.
LED Indicator Unit Status
Shows No Power Applied
DIMENSIONS - Model 332
DIMENSIONS - Model 362
Green Energized Red De-energized Flashing (Green or Red) Relay is Timing
11440 East P i n e Str e e t
Tuls a , O klahom a 7 4116
Page 2 of 3 02/2020
© 2020 TIME MARK CORPORATION
Page 3
MODEL 332 / 362
TIME MARK is a division of
1
Code: = switch OFF
2
= switch ON
4
81632
64
128
256
512
1
Code: = switch OFF
2
= switch ON
4
8
16
32
64
128
256
512
Interval Timer
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 332 OR 362.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation Instructions
ADJUSTMENT PROCEDURE - Model 362
The procedure to determine the switch selections for the digital Model 362 Interval Timer requires some simple calculations, which can be completed easily after the basic
steps are explained.
1. Convert the delay time required to minutes, seconds,
or tenths of seconds, depending upon the timing
range of the unit. For example:
7 hrs, 32 min = (7x60)+32 = 452 minutes 15 min, 2 secs = (15x60)+2 = 902 seconds
6.7 secs = (6.7*10) = 67 tenths of a second
2. To set the desired delay period on the timer, just add
the values of the selected dip switches (beginning
with the largest value first) to total the desired time.
e.g. #1: 100 seconds with a 1 second increment
64+32+4 = 100 seconds
e.g. #2: 100 seconds with a .1 second increment
512+256+128+64+32+8 = 1000 tenths of a seconds
WARRANTY
This product is warranted to be free from defects in materials and workmanship, and is covered by our
exclusive 5-year Unconditional Warranty. Should this
device fail to operate for any reason, we will repair it for five years from the date of manufacture. For complete warranty details, see the Terms and Conditions of Sales page in the front section of the Time Mark catalog or
contact Time Mark at 1-800-862-2875.
11440 East P i n e Str e e t
Tuls a , O klahom a 7 4116
Page 3 of 3 02/2020
© 2020 TIME MARK CORPORATION
Page 4
TIME MARK is a division of
Have Questions? Call us at (800) 862-2875 and talk to a real live person.
11440 E a s t Pin e S treet
Tuls a , O klahom a 7 4116
02/2020
© 2020 TIME MARK CORPORATION
Loading...