Timeguard WP401 Installation Instructions

tmQMN|jмднб_зс|белнкмЕлKисЗ==OLRLMS==PWOU=йг==m~ЦЙ=N
WP401 Weathersafe Instructions
The WP401 Multibox is a member of the Weathersafe range which is manufactured from tough, durable thermoplastic, and is intended for use in an outdoor environment, or one in which the protection provided by the Weathersafe range is required. All of the products in the range are rated IP65 or better, for protection against water and dust. All Weathersafe products must be tted according to the relevant instructions to maintain their IP rating once installed.
Introduction
This Weathersafe enclosure is designed to accommodate accessories such as trailing sockets with plugs and transformers that are pre-wired by the manufacturer.
The product should be mounted on a vertical surface, with cable entries at the bottom and not more than 1.5m above the ground. There is no earth terminal facility within this enclosure, ensure any accessory requiring an earth is connected via the incoming supply. The supply should be taken from a power outlet protected by a Ensure any exposed cable is suitable for use outdoors. Do not drill holes, apart from those for waterproof cable or conduit entries, into any part of the enclosure as this could impair
the IP65 weatherproof rating. A knockout for a waterproof 20mm cable gland or conduit entry is provided at the bottom of the box.
residual current device (RCD).
Installation
For permanent installation the product should be fastened to the wall using four No. 8, min 1.5in. long wood screws. To aid installation, a template for the four mounting holes has been provided on the reverse of this instruction leaet. Note - installation onto an uneven surface may cause the base to twist and prevent the lid from properly sealing, always check that the lid is properly located. If it is not, remove the lid, slacken one or more of the four base xing screws and try again.
For temporary installation the Multibox can be supported on the picture hook located at the top rear centre of the product. If conduit is to be used there must be sucient drainage
conduit entries must be used. If two cable entry positions are used with metal conduit, then earth continuity between the conduits must be maintained. If conduit is attached through the side or top surface then the drain hole must be drilled out (see g 3). Opening this drain hole
will reduce the IP rating of this product. Purchase the required length of cable to connect the socket strip provided to the supply outlet. Use 3 core 1.5 sq. mm for shorter
lengths or 2.5 sq. mm as an option for longer lengths. These cables are readily available at most DIY sheds. Connect this cable to the socket strip following the instructions provided on the reverse of this instruction leaet. Position socket strip on the velcro fastenings and press down. Plug in output plugs/transformers as required and position their
leads in the waterproof slots as shown in gs 1 and 2.
from the lowest points of the conduit, and waterproof cable glands or
TopTopTop
3 Year Guarantee
In the unlikely event of this product becoming faulty due
to defective material or manufacture within 3 years
date of purchase, please return it to your supplier in the
rst year with proof of purchase and it will be replaced
free of charge. For years 2 and 3 or any diculty in the
rst year telephone the helpline on
020 8450 0515.
of the
Drain
2 .giF1 .giF Fig. 3
Specications for the enclosure.
Degree of protection IP65 Maximum cable size 2.5 sq. mm, 3core Operating temperature range -20° to 40°C Installation temperature range 0° to 40°C
For a product brochure please contact:
Timeguard Ltd. Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020-8452-1112
or email csc@timeguard.com
67.058.144 - Issue 3
tmQMN|jмднб_зс|белнкмЕлKисЗ==OLRLMS==PWOU=йг==m~ЦЙ=O
Base Mounting
H o l e C e n t r e D i m e n s i o n s
Top Set (Left To Right): 199mm
Bottom Set (Left To Right): 176mm
Top to bottom: 293mm
199
Top
THIS WAY UP
176
176
293
Drain
NOTE: THE EXAMPLE DRAWING ABOVE IS NOT TO SCALE
Wiring Instructions
Remove velcro to reveal socket terminal cover screws.
6mm stripped
L Brown 25mm
N Blue 25mm
6mm stripped
E Green/Yellow 25mm
Loading...