Timeguard WP103, WP201, WP104, WP102, WP202 Installation & Operating Instructions Manual

...
INSTALLATION & OPERATING
INSTRUCTIONS
TIMEGUARD
WEATHERSAFE
®
OUTDOOR POWER
RANGE
General
Please note that all instructions are to be left with the consumer after installation.
The Weathersafe range is manufactured from tough, durable thermoplastic, and is intended for use in an outdoor environment, or one in which the protection provided by the Weathersafe range is required. All of products in the range are rated IP66, for protection against water and dust. All Weathersafe products need to be fitted with waterproof cable or conduit entries to maintain their IP rating once installed.
The Weathersafe range complies with the following standards:
IP66 rating: BS EN 60529
Socket outlets: BS 1363
RCD Units: BS 7288
Fused connection units: BS 1363
Isolating switches: BS EN 60669
Switches: BS 3676
All products in the range comply with the low voltage directive LV 72/23/EEC and where relevant EMC directive 89/336/EEC
Products covered by these instructions:
WP101 Weathersafe Single Gang Switched Socket WP102 Weathersafe Single Gang Isolated Switched Socket WP103 Weathersafe Single Gang DP Fused Connection Unit WP104 Weathersafe Single Gang RCD Fused Connection Unit WP201 Weathersafe Twin Gang Switched Socket WP202 Weathersafe Twin Gang Isolated Switched Socket WP203
Weathersafe Combined Twin Gang Isolated Timer & Socket
WP204 Weathersafe Twin Gang RCD Latching Socket WP205 Weathersafe Twin Gang RCD Socket WPL01 Weathersafe Single Gang 2 Way Switch (SP) WPL02 Weathersafe Twin Gang 2 Way Switch (SP) WPL03 Weathersafe Single Gang Switch - Bell Push WPL04 Weathersafe Single Gang DP Switch
Fig 1
Installation instructions
These products should be installed by a competent person (eg. qualified electrician) in accordance with these instructions and in compliance with the appropriate clauses of the current edition of the IEE wiring regulations. Sockets should be connected via a suitable RCD device.
Disconnect the mains electricity supply.
The Weathersafe range is designed to be mounted on a vertical flat surface, with socket outlets not more than 1.5 metres above the ground (this does not apply to switches).
To remove rockers from WPL range prise off using a flat blade screwdriver (figure 1). Use a piece of cloth or similar to prevent marking the unit. This allows access to the four fixing screws.