Time
indicator
Switching indicator & self-cancelling override 1=ON 0=OFF
Tough flame
retardant casing
24 hour
programme
ring
Protective lobes
Time control segments 1 tappet = 15 minutes Push towards programme ring = ON Push away from programme ring = OFF
Front socket
face
TS830 24 Hour Segment Timeswitch Setting Instructions
Turn the segment dial clockwise until the correct time of day is showing directly above the time indicator (the illustration shows
19.30 hours). Decide what time you would like the time controller to switch
your appliance ON and OFF. Simply push the segment tappets towards the time ring to set your ON times and away from the time ring for your OFF times. (The illustration above shows the time controller set to switch ON at 20.00 hours and OFF at 22.30 hours). These settings automatically operate the switching indicator when the time controller is in its operating condition. The switching indicator will show the switching condition 1=ON. 0= OFF. Minimum setting intervals = 15 minutes (one tappet segment).Minimum time between settings = 15 minutes.
Check your programme by manually turning the segment dial through a 24 hour cycle. Remember to re-set the dial back to the correct time of day. Simply plug the time controller into a socket and plug the appliance into the time controller. Switch on the socket and the appliance. The time controller is now in its operating condition.
Manual Override
You can switch your appliance ON and OFF at any time by using the self-cancelling switching rider on the top left of the unit. Simply turn anti-clockwise so the switching indicator on the front of the unit is positioned to either the 1=ON or 0=OFF position as illustrated. The override automatically cancels when the next ON/OFF programme operates.
2
3
2
2
2
1
2
0
1
9
1
8
1
7
1
2
4
2
3
2
2
2
1
2
0
1
2
Switching ON before selected time
ON
OFF
Switching rider
Switching OFF before selected time
5
6
OPERATING
INSTRUCTIONS
Points to note:
G
The segment dial can be turned even when the time controller is operating.
G
In case of power failiure, re-adjust the time controller to the correct time of day, turning the dial in a clockwise direction.
Important
This time controller is recommended for general domestic appliances up to 13 amp resistive or 5 amp inductive rating. Certain washing machines eg those with built-in delay timers and some electronic machines require permanently connected power and they cannot use this time controller.
Specifications
Operating Temp: 0°C to 40°C Operating Voltage: 220-240V AC 50Hz Switch Rating: 240V AC 13 amp resistive (3kW)
5 amp inductive Filament 300W
Conforms to Directives: 73/23/EEC & 89/336/EEC
Not suitable for fluorescent, low energy or discharge lighting.
3 Year Guarantee
In the unlikely event of this product becoming faulty, due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge.
Should you encounter any difficulty please contact our helpline on 020 8450 0515.
24 HOUR
SEGMENT
TIMESWITCH
Cat No. TS830
HELPLINE
020-8450-0515
For a product brochure please contact:
Timeguard Ltd.
Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020-8452-1112
or email csc@timeguard.com
Manufactured in the U.K. 67-058-39 (ISS 2)