Timeguard TRTD7N Installation Instructions

Digital Economy Seven
Programmer
Model: TRTD7N – White
I n s t allat ion & Operating Instructions
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
• Before installation or maintenance, ensure the mains supply to the time switch is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this time switch and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this time switch is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This time switch is of Class l Construction and must be earthed
• Switch Rating: 13A Resistive (3kW) Immersion Heaters
1
• Switch Type: Micro-disconnection ON control.
• 24 hour Programme: 10 selectable pre-set tariff
• Boost Times: 30, 60, 120 minutes
• Economy Output Light: Blue LED
• Battery Backup: 2 year reserve, factory fitted
• IP30 Rated suitable for restricted internal applications
• CE Compliant
• Dimensions (H x W x D): 111.5 x 170 x 60mm
Disconnection to immersion heater(s) via double pole rocker switch
programmes (0 – 9)
rechargeable non-replaceable
12 hour display (back lit during programming) Economy light Programming buttons
OFF/Timed switch
Boost button (illuminated in use)
4. Installation
Suitable for use with single, dual, or twin element immersion heaters.
4.1 Ensure the mains supply is switched off and the circuit supply fuses
2
are removed or the circuit breaker turned off.
4.2 Remove the 2 fixing screws holding the front panel to the back box.
4.3 Decide which mounting holes you would like to use and select a suitable cable entry point by drilling into the back box ensuring not damage or infringe on any of the internal components.
4.4 Mark the position of the mounting holes on the wall using the back box as a template. Drill out the mounting holes taking care to avoid any joists, electrical cables or water/gas pipes that may be hidden beneath the surface. Insert the rawl plugs into the holes.
4.5 Pass the 230V 50Hz mains supply and load cables through the cable entry point(s) on the back box.
4.6 Fix the back box to the wall using the correct mounting screws for the rawl plugs installed.
4.7 Use the cable clamp in the back box to secure the cables.
4.8 Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved (See section 5. Connection Diagram).
4.9 Select and set your preferred program and time setting using the adjusters located on the reverse of the front panel (See section 6. Commissioning).
230V~50Hz MAINS SUPPL
L
E
N
Neutral
Load
Earth
5. Connection Diagram
Connect the cables to the terminal block which are marked as follows;
• 230V 50Hz mains – Single element immersion heaters only.
1 2 3 4 5
Y
Link or Bridge
Wire
Heater
3
230V 50Hz Mains Supply
Live Supply (Brown or Red) to terminal 1 Neutral Supply (Blue or Black) to terminal 2 Earth (Green/Yellow) to
LOAD
Off Peak
Load
Switch Live, Off peak load (Brown or Red) to terminal 5 Heater Neutral (Blue or Black) to terminal 3 Earth (Green/Yellow) to
Note: a link or bridge will need to be fitted between terminal 4 and terminal 5 if you wish to use the Boost button (single element immersion heaters only).
• 230V 50Hz mains – Twin or Dual element immersion heaters.
1 2 3 4 5
230V~50Hz MAINS SUPPLY
L N
E
Heater Neutral
Boost Load
Off Peak Load
4
230V 50Hz Mains Supply
Live Supply (Brown or Red) to terminal 1 Neutral Supply (Blue or Black) to terminal 2 Earth (Green/Yellow) to
Load
Switch Live, Off peak load – Primary element (Brown or Red) to terminal 5
Switch Live, Boost load – Secondary element (Brown or Red) to terminal 4
Heater Neutral (Blue or Black) to terminal 3 Earth (Green/Yellow) to
LOAD
Earth