These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
thermostat is switched off and the circuit supply fuses are removed
or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this thermostat and install in accordance with the current
IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this thermostat is
fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
• To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
Receiver
• 230V AC 50 Hz
1
• This thermostat is of Class ll Construction and must not be earthed
• Switch Rating:3(1)A
• Switch Type:Single pole, voltage free
• Connection Type:3 wire
• Micro Disconnection:Type 1.B control action
• Illumination:Blue LED illuminated on setting
• Output Light:Red LED
• Installation Type:Surface mount with wall plate
• CE Compliant
• Dimensions (H x W x D):90 x 95 x 30mm
changeover contacts
for button surrounds
Page 3
Transmitter
• Batteries:2x 1.5V AA
• Operating Temperature Range: 0°C to +40°C
• Set Temperature Range:10°C to 30°C
• Temperature Swing Adjuster: +/- 0.5°C or 1.0°C set by DIP switch
• PID Adjustment:ON or OFF set by DIP switch
• Boiler Type Adjustment:3CYC = Gas, 6CYC = Oil, set by DIP switch
• Frost Protection Mode:5°C
• Night Set Back Mode:Lowers set temperature
by 4°C for 1-9 hours
• Transmission:868.3MHz
• Illumination:Blue LED illuminated on setting
for button surrounds and display
• Installation Type:Surface mount with wall plate
• CE Compliant
• Dimensions (H x W x D):90 x 95 x 30mm
Transmitter Front View
2
Digital room temperature display
(illuminated on setting)
Night set-back (reduces temperature
by 4°C, 1-9 hours recall) and frost
protection setting mode
10°C to 30°C
set temperature
range
The heating symbol
will show when heat
is demanded
+/- setting
buttons
(illuminated
on setting)
Flip down cover for display battery
compartment and reset button –
uses 2x 1.5V AA batteries supplied
Page 4
Receiver Front View
Learn/Manual Light,
Blue LED
Output ON light,
Red LED
Learn button enabling communication between the transmitter
and receiver, also control button for output in manual mode
Automatic/Manual mode button
4. Siting
Receiver
• The TRT047 Receiver should be mounted close to the items it will be
3
controlling i.e. boiler, control valves and pump.
• It should be mounted in a position where its control buttons and indicator
lights can be easily accessed.
Transmitter
• The TRT047N Transmitter must be sited where it will not be influenced
by heat sources, for example above a radiator or a television or
a refrigerator/freezer or in direct sunlight or subjected to draughts.
• The product requires air circulation, so do not position above
or below shelving or other wall mounted obstacles.
• It should be mounted approximately 1.5 metres above floor level.
5. Installation
Receiver
5.1 Ensure the mains supply is switched off and the circuit supply fuses are
removed or the circuit breaker turned off.
5.2 Remove the wall plate from the receiver unit, by undoing the retaining
screws, and pivoting the bottom of the unit outwards. The TRT047N
receiver body can then be lifted off.
Page 5
5.3 Mark the position of the mounting holes on the wall using the wall plate
as a template. Drill out the mounting holes taking care to avoid any
joists, electrical cables or water/gas pipes that may be hidden beneath
the surface. Insert the rawl plugs into the holes.
5.4 Pass the 230V 50Hz mains supply and load cables through the opening
of the wall plate. Allow sufficient excess cable to wire up the unit, but
not too much to make it difficult to close the unit to the wall plate.
5.5 Fix the wall plate to the wall using the correct mounting screws for the
rawl plugs installed. The retaining screws which secure the unit to the
wall plate should be at the bottom.
5.6 Terminate the cables into the terminal block ensuring correct polarity
is observed and that all bare conductors are sleeved (See section 6.
Receiver Connection Diagram). Make sure that the curved washer grips
the conductor.
5.7 To reinstall the unit onto the wall plate, first ensure the wall plate
retaining screws are loosened enough to clear the TRT047N receiver
body, then engage the top of the TRT047N receiver onto the wall plate
retaining tabs, and push firmly downwards and then upwards.
There will be some resistance from the terminals.
5.8 Once in place, secure with the retaining screws making sure
4
not to over tighten.
Receiver Wall Plate
Alternate mounting holes
Retaining tabs
Wall plate retaining screws
Mounting
holes
Page 6
Transmitter
5.9 Remove the wall plate from the transmitter unit, by undoing the
retaining screws, and pivoting the bottom of the unit outwards.
The TRT047N transmitter body can then be lifted off.
5.10 Mark the position of the mounting holes on the wall using the wall plate
as a template. Drill out the mounting holes taking care to avoid any
joists, electrical cables or water/gas pipes that may be hidden beneath
the surface. Insert the rawl plugs into the holes.
5.11 Fix the wall plate to the wall using the correct mounting screws for the
rawl plugs installed. The retaining screws which secure the unit to the
wall plate should be at the bottom.
5.12 To insert batteries into the unit, first lower hinged flip down cover and
carefully lever the battery holder cover off. Insert the 2x AA batteries
supplied into the battery holder maintaining the correct polarity,
as shown in the base of the battery holder. Re-position the battery holder
cover and click into place.
5.13 To reinstall the unit onto the wall plate, first ensure the wall plate
retaining screws are loosened enough to clear the TRT047N transmitter
body, then engage the top of the TRT047N transmitter onto the wall
5
plate retaining tabs, and push firmly downwards and then upwards.
There will be some resistance from the terminals.
5.14 Once in place, secure with the retaining screws making sure
not to over tighten.
Transmitter Wall Plate
Alternate mounting holes
Retaining tabs
Wall plate retaining screws
Mounting
holes
Page 7
6. Connection Diagram
Connect the 230V 50Hz mains supply and load cables to the terminal block
which are marked as follows;
6
230V AC 50Hz
MAINS SUPPLY
230V 50Hz Mains Supply
Live Supply (Brown or Red) toL
Neutral Supply (Blue or Black) toN
A ‘Loop Terminal’ is provided should a 3 core cable
be used
Load (Boiler)
Switch Live (Brown or Red) toNO
COMNO
Note: Check boiler instructions
NC
Connections to boiler
before connecting
Supply
Neutral
N
L
Supply
Live
Page 8
7. Transmitter DIP Switch Settings
•The temperature swing can be adjusted between 0.5°C and 1.0°C by
selecting the desired DIP switch position found on the rear of the unit.
We suggest using 0.5°C position unless the boiler turns ON and OFF
too rapidly. Press the reset button after changing.
•The PID ‘Proportional-Integral-Derivative’ can also be selected ON or
OFF using the DIP switches on the rear of the unit. We suggest setting
this to the ON position. As the room temperature approaches the set
temperature, the thermostat will intermittently turn the heating ON
and OFF, to help prevent temperature over-shoot.
Press the reset button after changing.
•The boiler type can be set to either 3CYC (Gas) or 6CYC (Oil),
using the DIP switches on the rear of the unit.
Press the reset button after changing.
TRT047N Rear of Transmitter
DIP switch for PID settingDIP switch for
boiler type setting
7
DIP switch for temperature
swing adjustment setting
Page 9
8. Pairing the Devices
•Make sure you have selected the desired DIP switch settings located
on the back of the transmitter.
•Press the reset button of on the front of the transmitter, and connect
the power to the receiver.
•Both the Learn/Manual light, and the Red output light on the receiver
8
will illuminate for approximately 3 seconds, then go out.
Press the Reset button
located beneath the
drop down flap
•Press and hold the Learn button on the front of the receiver for
10 seconds until the blue Learn/Manual light starts flashing,
the button surrounds will illuminate.
Page 10
•On the transmitter, press and hold both the + and Frost/Night
Set-back buttons at the same time until the flashing blue Learn/Manual
light goes off. This should take approximately 3 seconds.
9
•The transmitter and receiver are now paired.
Page 11
9. Operation
• The default set temperature is 22°C.
Adjusting Set Temperature
• Use the +/- setting buttons to change the set temperature.
10
• The set temperature will flash while the change is being made.
• The set temperature change will be made in 0.5 degree increments,
and the +/- button surround and display light will illuminate upon setting.
• The set temperature and illumination will time out 5 seconds after the last
button press, saving your settings, and the display will revert to show the
current room temperature.
• When the room temperature is below the set temperature, the heating
symbol will appear on the display to indicate output.
Heating symbol will show when
heat is demanded.
Page 12
The Red output ON light
will illuminate indicating
it is demanding heat
Frost Protection Mode
• Press the Frost/Night set-back button on the transmitter and hold for
3 seconds, the button surround and display light will illuminate.
11
• The frost symbol will appear and continuously flash on the screen.
The set temperature will change to 5°C. The button surround,
and display illumination will time out after 5 seconds.
Frost symbol will continuously flash
when frost mode is active
• To disable the frost protection mode, press and hold the Frost/Night
set-back button for 3 seconds. The frost symbol will disappear.
Page 13
Night Set Back Mode
• The night set back reduces the set temperature by 4°C for a set amount
of hours. This can be set between 1 and 9 hours.
• Press the Frost/Night set-back button once on the transmitter to activate,
the button surround and display light will illuminate.
• The display will show 1 hour flashing.
12
• Use the +/- buttons to set the desired hours, the button surround
will illuminate.
Page 14
• When the correct number of hours is selected, the display will time out
3 seconds after the last button is pressed. The display will then alternate
every 2.5 seconds between the number of hours of night set back
remaining, and the current room temperature. The Night set back
bed symbol will flash continuously whilst active.
The night set back bed symbol will
continuously flash when night set back
is active.
• Press the frost/night set back button once again to cancel.
Battery Low Indicator
• When the batteries are low, the battery low indicator comes on.
13
Battery low indicator will appear
when the batteries are low.
Page 15
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective
material or manufacture within 3 years of the date of purchase, please
return it to your supplier in the first year with proof of purchase and it
will be replaced free of charge. For the second and third years or any
difficulty in the first year telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible
replacements (where agreed by Timeguard) the customer is responsible
for all shipping/postage charges outside of the UK. All shipping costs
are to be paid in advance before a replacement is sent out.
14
Page 16
If you experience problems, do not immediately
return the unit to the store.
Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
www.timeguard.com
Zerofour – January 2018
67.058.607 (Issue 1)