Cylinder/Pipe Thermostat
Model: TRT044
Installation & Operating Instructions

1. General Information
These instructions should be read carefully before installation and retained
for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
cylinder/pipe thermostat is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this cylinder/pipe thermostat and install
in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this cylinder/pipe
thermostat is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.
• To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
• Operating Voltage: 230V AC 50 Hz
• Switch Rating: 16A Resistive, 3kW
1
• Switch Type: Single pole, double throw (SPDT)
• Operating Temperature Range: 0°C to +55°C
• Set Temperature Range: +40°C to +80°C
• CE Compliant
• Dimensions: H=105mm, W=38mm, D=56mm

4. Siting
• The TRT044 is designed to be surface mounted onto the domestic
hot water cylinder.
• For cylinders with an insulating foam covering, a section of foam
must be removed so the back of the thermostat is in direct contact
with the metal body of the tank.
• The TRT044 should be mounted between a quarter and third of the
way up from the base of the tank in a position that gives good access
to the temperature adjustment knob.
5. Installation
4.1 Ensure the mains supply is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
4.2 Unscrew and remove the cover retaining screw, and carefully
ease off the temperature adjustment knob.
4.3 Remove the front cover.
4.4 Loosen the cable gland and thread the incoming 230V 50Hz
mains supply cable into the unit.
Note: Allow sufficient excess cable to wire up the unit, but not too
3
much to make it difficult to close the cover on the unit.
4.5 Prepare the cable for termination.
4.6 Connect the cable to the relevant terminals ensuring that the brass
washers grip the wires firmly (see section 6. Connection Diagram).
4.7 Pull some of the excess cable back through the cable gland
and tighten to the trap the cable and give good strain relief.
4.8 Re-position the cover over the unit, along with the cover retaining
screw and temperature adjustment knob.
4.9 Adjust the length of the spring wire, and use it to strap the TRT044
to the hot water cylinder.
4.10 Restore mains to the unit after checking all system wiring is complete.

6. Connection Diagram
• Note: Check boiler instructions before connecting
TRT044
Cylinderstat
+ °C
230V 50Hz Mains Supply
C = Live Supply Input
1 = Switched Live Output
(terminals C and 1 make
C
21
temperature on fall)
2 = Switched Live Output
(terminals C and 2 make
temperature on rise)
4
7. Operation
• Use the temperature adjustment knob to set the desired temperature.
Note: For vulnerable people it may be advisable to reduce the setting
to as low as +50°C bearing in mind the outlet water temperature
will be somewhat higher than this due to the temperature stratification
in the tank.
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material
or manufacture within 3 years of the date of purchase, please return it to
your supplier in the first year with proof of purchase and it will be replaced
free of charge. For the second and third years or any difficulty in the first year
telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements
(where agreed by Timeguard) the customer is responsible for all shipping/
postage charges outside of the UK. All shipping costs are to be paid
in advance before a replacement is sent out.

If you experience problems, do not immediately
Telephone the Timeguard Customer Helpline;
return the unit to the store.
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
www.timeguard.com
Zerofour – May 2017
67.058.330 (Issue 3)