Timeguard TRT033N Operating Instructions Manual

Installation & Operating Instructions
Digital Room Thermostat
with Night Set-back
Model: TRT033N
1
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the thermostat is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this thermostat and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
• To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
• 230V AC 50 Hz
• This thermostat is of Class ll Construction and must not be earthed
• Switch Rating: 3(1)A
• Switch Type: Single pole, voltage free changeover
contacts
• Connection Type: 2 wire
• Installation Type: Surface mount with wall plate
• Micro Disconnection: Type 1.B control action
• Operating Temperature Range: 0°C to +40°C
• Set Temperature Range: 10°C to 30°C
• Temperature Swing Adjuster: +/- 0.5°C or 1.0°C set by DIP switch
• Frost Protection Mode: 5°C
• Night Set Back Mode: Lowers set temperature by
4°C for 1-9 hours
• PID Adjustment: ON or OFF set by DIP switch
2
3
• Boiler Type Adjustment: 3CYC = Gas, 6CYC = Oil, set by DIP switch
• Illumination: Blue LED illuminated on setting for button
surrounds and display
• Batteries: 2x 1.5V AA
• CE Compliant
• Dimensions (H x W x D): 90 x 95 x 30mm
TRT033N Front View
Digital room temperature display (illuminated on setting)
10°C to 30°C set temperature range
The heating symbol will show when heat is demanded
Night set-back (reduces temperature
by 4°C, 1-9 hours recall) and frost
protection setting mode
+/- setting
buttons
(illuminated
on setting)
Flip down cover for display battery
compartment and reset button –
uses 2x 1.5V AA batteries supplied
3
4. Siting
• The TRT033N must be sited where it will not be influenced by heat sources, for example above a radiator or a television or a refrigerator/freezer or in direct sunlight or subjected to draughts.
• The product requires air circulation, so do not position above or below shelving or other wall mounted obstacles.
• It should be mounted approximately 1.5 metres above floor level.
5. Installation
5.1 Ensure the mains supply is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
5.2 Remove the wall plate from the unit, by undoing the retaining screws,
and pivoting the bottom of the unit outwards. The TRT033N body can then be lifted off.
5.3 Mark the position of the mounting holes on the wall using the wall plate
as a template. Drill out the mounting holes taking care to avoid any joists, electrical cables or water/gas pipes that may be hidden beneath the surface. Insert the rawl plugs into the holes.
5.4 Pass the 230V 50Hz mains supply and load cables through the opening
of the wall plate. Allow sufficient excess cable to wire up the unit, but not too much to make it difficult to close the unit to the wall plate.
5.5 Fix the wall plate to the wall using the correct mounting screws for the
rawl plugs installed. The retaining screws which secure the unit to the wall plate should be at the bottom.
5.6 Terminate the cables into the terminal block ensuring correct polarity
is observed and that all bare conductors are sleeved (See section 6. Connection Diagram). Make sure that the curved washer grips the conductor.
5.7 To insert batteries into the unit, first lower hinged flip down cover
and carefully lever the battery holder cover off. Insert the 2x AA batteries supplied into the battery holder maintaining the correct polarity, as shown in the base of the battery holder. Re-position the battery holder cover and click into place.
Loading...
+ 8 hidden pages