Time Guard PanelMASTER MEU11, PanelMASTER EMU11, PanelMASTER EMU17, PanelMASTER MEU17 Installation & Operating Instructions Manual

INSTALLATION & OPERATING
ON
INSTRUCTIONS
Panel
MEU11 (24 Hour) MEU17 (7 Day)
(Giving Panel Mount Capability) EMU11 (24 Hour) EMU17 (7 Day)
Timer Modules
Without Housing
With Housing
1. Physical Arrangements & Installation Instructions
MEU 11 & MEU 17
Metal Hydride Battery
Pin Header
Engineering drawing can be supplied on request
EMU 11 & EMU 17
Change button
Figure 1
Programme button
Tamper proof
Contents
1 EMU11 (24 hour) or EMU17 (7 day) 1 Panel mount bezel 1 Tamper proof cover 4 Surface mount stand offs (length 10mm) 2 Panel mount bolts 2 Self-tapping screws (No. 4 x 5/8 in) for panel mount bolts 2 Self-tapping screws (No.6 x 3/8 in) for attaching bezel to EMU11/17
cover
Bezel for panel
mounting
Panel mount
bolts
Slide switch allowing
continuous ON or
OFF or programmed
operation
mount fixing
Surface
Fig 2
67mm
67mm
R 3.5mm
Fig 3
Use No. 6 x 3/8in self­tapping screws to fully secure bezel to EMU11/17 (fixed from rear)
Fig 4
Bezel
No. 4 x 5/8in self­tapping screw
Surface Mounting
The EMU11/17 without bezel can be surface mounted using the 4 securing holes as shown in figure 5. The unit can be stood off from the mounting surface by 10mm using the 4 spacers if required. Screws are not provided and it must be remembered that if used in this way the EMU11/17 must be installed within a housing or cubicle to prevent access to the mains terminations.
Installation - Panel Mounting
For panel mounting (in panels up to 7.0mm thick with the cut-out as shown in figure 2) the EMU11/17 should be snapped into the bezel supplied and secured in place by the use of the 2 No. 6 x 3/8in self-tapping screws provided as shown in figure 3. When selecting a position for the unit it should be born in mind that a clearance behind the front panel surface of 26.0mm is required over the full area of the panel cut-out. The unit is designed to be mounted from the front of the panel by the following procedure: a. Insert the 2 bolts provided in the locations
shown in figure 4.
b. Then insert the 2 No. 4 x 5/8 in self-tapping
screws into the bolts and engage thread.
c. Make connections to the unit by wires
terminated in a Molex 4 way 7720 or similar connector from behind the panel.
d. Insert the EMU11/17 complete with bezel into
the panel and tighten up the 2 No. 4 self­tapping screws. The ears on the bolts will
Bolt
rotate under the tightening action to clamp the unit to the panel.
4 fixing holes for surface mounting
Fig 5
2. Specifications MEU11 & EMU11
4 ON/OFF programmes
Easy 2 button programming
Change/Override until next programme
Rechargeable Metal Hydride battery back-up with 1000 hours reserve
Requires only an external diode, resistor and relay to switch mains
Temperature range 0° to 55°C
Operation
The programme button advances programme steps and the change button the hours and minutes which flash. Time of day is set first and is updated during the programming period. Programmes 1 to 4 follow. If, during programming, no button is pressed over a period of one minute then the display will revert to normal operation. In normal operation, pressing the change button changes the output until the next programme step.
Single Resistor PSU (MEU11 & MEU17 only) Two Resistor PSU - gives Optimum EMC Performance