Timeguard NTT07, NTT06 Installation Instructions

Digital Time Switch
Model: NTT06
24 Hour General Purpose
Digital Timer
Model: NTT07
7 Day General Purpose
Digital Timer
Installation & Operating Instructions
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the time switch is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this time switch and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this time switch is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This time switch is of class I construction and must be earthed
• Switch Rating: 16A Resistive (3.68kW) Immersion Heaters
2400W incandescent
and halogen lighting
750W fluorescent
lighting
100W Compact
fluorescent & LED lighting
The LED switching capabilities of this product can be increased to 200W by the addition of the Timeguard ZV900 Automatic switch load controller – sold separately.
• Switch Type: 16A relay
• Voltage free contact if wire link is removed
• Contact Type: Normally Open and Normally Closed
• Manual Override: Permanent ON or OFF
• Boost Times: 1 or 2 hour
• Power Status LED Indicator: Red
• Output LED Indicator: Green
• NTT06: 24 Hour Time Period, Up to 48 programmes per day
• NTT07: 7 Day Time Period (7 Day, 5 + 2 Days or Individual Day), 4 ON/OFF switching programmes per day
• Operating Temperature: 0°C to +40°C
• CE Approved
Note: Not suitable for use with
Discharge Lighting.
Power LED
Output LED
Illuminated screen
Advance button
Programme button
Reset button
Boost button
Time button
Terminal cover
4. Installation
• Ensure the mains supply is switched off
3 4
and the circuit supply fuses are removed or the circuit breaker turned off.
• Remove the terminal cover by undoing the fixing screw on the bottom of the time switch.
• Mark the position of the top wall mounting screw. Drill out the top mounting hole taking care to avoid any joists, electrical cables or water/gas pipes that may be hidden beneath the surface. Insert the rawl plug into the hole.
• Fix the top mounting screw and leave
2.5mm proud off of the wall.
• Place the key hole in the top of the product, over the screw head, and slide down.
• Mark the position of the lower mounting hole on the wall using the wall plate as a template.
• Remove the product and drill out the lower mounting hole again taking care to avoid any joists, electrical cables or water/gas pipes that may be hidden beneath the surface. Insert the rawl plug into the hole.
• The 230V 50Hz supply and load cables can enter through the rear knock outs or the front cable entry ports provided. If the rear knock outs are being used, remove the blanking plates and pass the supply and load cables through the holes.
• Place the key hole in the top of the product again, over the screw head, and slide down.
• Secure the unit to the wall using the lower mounting screw.
• If the wiring is through the front cable entry ports, use the cable clamps provided to secure the supply and load cables.
• Terminate the supply and load cables to
4 5
the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved. Please note the connections are marked beneath the terminal block (see section 5. Connection Diagram).
• Secure the terminal cover back into place using the fixing screw.