Timeguard NTM01 User Manual

24 Hour
Mechanical Time
Switch
Model: NTM01
Analogue Timer Module
Installation & Operating Instructions
NTM01 – Analogue Timer Module
ON segment
Programme ring
Time indicator
Time control segments: 1 segment = 15 minutes,
1
push segment down for ON, pull up for OFF.
1. General:
Control switch:
1 = permanently ON, Timer symbol = timed control, 0 = permanently OFF.
2. Features:
Permanent ON/OFF facility. This enables the heater under control to be turned OFF when alternative methods of heating are available, or during a holiday period. It also enables the heater to be permanently turned ON.
Shortest switching time of 15 minutes increasing in 15 minute steps.
Up to 48 programmes per day.
3. Installation:
We recommend that this unit be fitted by a qualified electrician. Install in accordance to wiring and current building regulations. Please read the instructions carefully. If in any doubt contact the Timeguard Helpline.
2
Important: Switch off mains electricity before commencing work.
Connect the installation wiring to the module, according to the legend printed on the back of the module, or according to the listing below.
L Live supply.
N Neutral supply.
1 COM.
➝ ➝
2 Normally open.
3 Normally closed.
4. Programming the time switch:
a) Decide what times you would like the time switch
to switch ON and OFF.
b) Push the required segments down for the duration
of an ON period, and pull them up for the duration of an OFF period. The minimum switching interval is 15 minutes, and this can be increased in 15 minute steps.
c) Set the correct time, by rotating the dial clockwise
until the correct time is indicated by the triangular pointer. Note that as the dial is rotated there will be an increased resistance to turning as ON/OFF periods are passed.
Points to note:
The segment dial can be turned whilst the time
3
controller is operating.
In case of power failure, re-adjust the time controller to the correct time of day by turning the dial in a clockwise direction until the correct time is indicated by the pointer.
5. Permanent Override:
The main slider on the timer can be set to permanent on by sliding it to the left, aligning the arrow head to the 1 symbol.
In the middle position, with the arrow head pointing at the timer symbol, the timer is in automatic mode.
If the slider is moved to the right, and the arrow head points at the 0 symbol, the timer is permanently OFF.
6. Specifications:
62.5 Dia.
3.3 Dia.
60 Sq.
54 CTS
54 CTS
Operating temperature: 0°C to 40°C
Operating voltage: 230V 50Hz
Switch rating: 16A resistive, 8A inductive, 1 HP, 750W incandescent, 750W halogen, 750W fluorescent, 100W compact fluorescent.
Switch type: 22A micro switch
Voltage free contact: Yes
Contact type: Single pole change over
Time period: 24 hours
Note: Product not suitable for discharge lighting.
4
7. Mounting Details:
54 CTS
54 CTS
21
62.5 Dia.
3.3 Dia.
60 Sq.
35.5
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515.
Note: a proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside the UK. All shipping costs are to be paid in advance before a replacement is sent.
For assistance with the product please contact:
HELPLINE
020 8450 0515
or email helpline@timeguard.com
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Offi ce: 020 8452 1112
or email csc@timeguard.com
67.058.477 (issue 3).
Zerofour – July 2013
Loading...