Timeguard MLTP180WH, MLTP180BK Installation Instructions

180° Tamper-proof
Wall Mounted PIR
Model: MLTP180BK – Black
Model: MLTP180WH – White
I n s t allat ion & O perating Instructions
1
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this PIR sensor is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This PIR sensor is of Class II Construction and must not be earthed
• Detection Range: Up to 12m at a 2.5m mounting height
• Detection Angle: 180°
• Maximum Switching Load: 2300W Halogen Lighting 500W Fluorescent and LED Lighting
• Time ON Adjustment: 2 seconds to 30 minutes
• Warm Up Time: 30 seconds
• Lux Adjustment: 2 to 1000 lux
• Operating Temperature: -25°C to +45°C
• Manual Override: Double pulse within 2 seconds, to enter 6 hours ON time (night time only).
• Back Box Mounting Centres: 60mm
• IP55 Rated suitable for restricted external applications
• CE Compliant
• Dimensions (H x W x D): 81.8 x 81.8 x 67.1mm
2
4. Selecting a Location
• Careful positioning of the sensor will be required to ensure optimum performance. The mounting height for the sensor should be 2.5m. See diagram A.
• The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS. Therefore position the unit so that the sensor looks ACROSS the likely approach path.
• Avoid positioning the sensor where there are any sources of heat in the detection (extractor fans, tumble dryer exhausts etc.). See diagram B.
• Reflective surfaces (i.e. pools of water or white-painted walls) may cause false activation under extreme conditions.
A
B
3
5. Installation
5.1 Ensure the mains supply is switched OFF
and the circuit supply fuses are removed or the circuit breaker turned OFF (See image 1).
5.2 An isolating switch should be installed to enable the power to be switched
ON and OFF for maintenance purposes and to activate the manual/auto override function.
5.3 Use a 2.5mm Allen key to unlock the captive latch located on the bottom
of the sensor, by turning it anti-clockwise (quarter turn) so the dot indicator aligns with the ‘Unlock’ symbol, then pull downwards (See image 2, a). Note: the captive latch cannot be removed. Use a flat head screwdriver to press in the lugs on each side of the PIR sensor to unfasten the front cover (See image 2, b).
5.4 With both lugs pressed in, remove the font cover by pulling it away
from the PIR sensor (See image 3).
1
2
3