Timeguard MLB3000 User Manual

3000W MULTI PIR
LIGHT CONTROLLER
Cat No. MLB3000 - Black
INSTALLATION & OPERATING
Cat No. MLW3000 - White
Installation & Operating
INSTRUCTIONS
SECTION ONE
GENERAL INFORMATION
The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation.
PARTS INCLUDED
- PIR Sensor unit.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack.
TOOLS & PARTS NEEDED
- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver
- Large slotted/philips screwdriver
- Wire cutters
This product is suitable for wall or ceiling mount. Lighting loads connected must not exceed maximum 3000W filament/incandescent, 500W fluorescent/low energy.
SECTION TWO
SELECTING THE LOCATION
The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). A moving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the unit mounted at the optimum height of 2.5m.
Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction.
The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.). Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions.
During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation.
SECTION THREE
INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows:
Switch off the electricity at the fuse box by removing the relevant fuse or
switching off the circuit breaker before proceeding with the installation.
Remove the wiring box cover by unscrewing the retaining screw (fig F) and with a screwdriver gently push down and ease out. The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm2 gauge is used. A isolating switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes.
Mark the position of the fitting holes. Drill the holes. Insert the rawl plugs into the holes.
PIERCE & PASS THE CABLE(S) THROUGH THE GROMMET(S) BEFORE PROCEEDING.
Fix the mounting plate to the wall. Take care not to overtighten the screws to prevent damage to the mounting plate. If using a power screwdriver, use the lowest torque setting.
CONNECTION
This unit is supplied with a hanging attachment (tether) to aid installation. If it is not required, simply remove from the unit and discard.
Place the round end of the tether into the keyhole shape location hole on the wall bracket. Ensure the tether is securely fixed into the slot before releasing the weight of the unit.
The unit can now be suspended below the wall bracket. (Fig D)
Connect the mains supply cable to the terminal block as follows (see connection diagram):
NEUTRAL (Blue) N EARTH (Green/Yellow) LIVE (Brown) L
Connect the cable from the lighting load to the terminal block on the unit as follows: (see connection diagram)
NEUTRAL (Blue) N EARTH (Green/Yellow) LIVE (White) L1
Ensure the connections are secure. Place terminal block onto its securing pillar on the wall bracket (Fig E) Remove and discard the tether. Fit control to wall bracket and secure by fixing screw (Fig F)
*** IMPORTANT ***
TOP VIEW
SIDE VIEW
2.5m
200ยบ
A C
12m
Less sensitive
More sensitive
B
D