Timeguard MEU11, MEU17, EMU11, EMU17 Installation & Operating Instructions Manual

Installation & Operating Instructions
Timer Modules
MEU11 – 24 Hour Module,
MEU17 – 7 Day Module
(Without Housing)
EMU11 – 24 Hour Module,
EMU17 – 7 Day Module
1
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the 3V DC supply to the timer module is switched off.
• It is recommended that a qualified electrician is consulted or used for the installation of this timer module and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit before attempting to use the time module for your OEM application.
3. Technical Specifications
General
• Requires an external diode, resistor and relay to switch mains voltage.
• Manual Override – ON/OFF until next programme.
• Operating Temperature – 0°C to +55°C.
• Power Reserve – Non replaceable rechargeable factory fitted battery, Metal Hydride, 1000 hours.
• CE Compliant.
2
MEU11 & EMU11 24 Hour Modules
• 24 Hour Time Period – 4 ON/OFF programmes.
MEU17 & MEU17 7 Day Modules
• 7 Day Time Period – 6 ON/OFF programmes, daily, weekly, weekend or weekday options.
4. Contents
• 1x Timer module.
• 1x Panel mount bezel.
• 1x Tamper proof cover.
• 4x Surface mount stand offs (length 10mm).
• 2x Panel mount bolts.
• 2x Self-tapping screws (No. 4 x 5/8in)
for panel mount bolts.
• 2x Self-tapping screws (No. 6 x 3/8in)
for attaching bezel to EMU11.
5. Installation
3
Panel Mounting
For panel mounting (in panels up to 7.0mm
thick with the cut-out as shown in figure 2) the EMU11/17 should be snapped into the bezel supplied and secured in place by the use of the 2x No. 6 x 3/8 in self-tapping screws provided (as shown in figure 3).
When selecting a position for the unit, bear in
mind that a clearance behind the front panel surface of 26.0mm is required over the full area of the panel cut-out.
The unit is designed to be mounted from the
front of the panel by the following procedure;
4
5.1 Insert the 2 bolts provided in the locations as
shown in figure 4.
5.2 Then insert the 2x No.4 x 5/8 in self-tapping
screws into the bolts and engage thread.
5.3 Make connections to the unit by wires
terminated in a Molex 4 way 7720 or similar connector from behind the panel.
5.4 Insert the EMU11/17 complete with bezel into
the panel and tighten up the 2x No.4 self­tapping screws. The ears on the bolts will rotate as you tighten to clamp the unit to the panel.
Surface Mounting
• The EMU11/17 without bezel can be surface mounted using the 4 securing holes as shown in figure 5.
• The unit can be stood off from the mounting surface by 10mm using the 4 spacers if required.
• Screws are not provided and it must be remembered that if used in this way the EMU11/17 must be installed within a housing or cubicle to prevent access to the mains terminations.