1. Designated Use
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
LEDX30PIR is an outdoor motion detector for automatic LED lighting control.
Mainly for wall installation.
Simple plug in wall plate for easy & safe connection
Suitable for a wide range of locations: corridors, gardens, staircases,
entrances, garages, outdoor parking areas etc.
WARNING
2. Basic Safety Instruction
Danger of death through electric shock.
Must only be installed by quali ed electricians.
Avoid the metal parts of the device due to potentially high temperature.
Conforms to the latest EC directives.
1
Designed for use in normal environments
Intended for outdoor installation.
Energy saving.
Long LED lamp life time.
Index :
Page 2 Contents and Tools required
Page 3 Connection and Installation procedure
Page 4 Installation procedure
Page 5 Sensor detection range
Page 6 Walk test & adjustment, Detector head adjustment
Page 7 Knob settings
Page 8 Lens masking
Page 9 Lamp adjustment and Warning
Page 10 Technical Specifications
Page 3
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
3. Contents:
What’s in the box?
Screw:
M4x32mm
X 1
INSTRUCTIONS
MANUAL
2 3
X 1
X 1
X 1
X 2 X 2
X 2 X 4
Screw peg:
6x30mm
Screw:
M3x12mm
Product’s weight: LEDX30PIR : 1kg
4. Tools required:
Tools / Equipment need for installation.
Flat blade screw driver Suitable for screw head Drill bit with diameter 6mm
X 1
X 1
X 1
Page 4
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
5. Connection:
Master-Slave connection
Connect the cable to the terminal block as follows (see connection diagram): Ensure the connections are secure. Refit wall plate ensuring it clicks
firmly into place.
BROWN
LIVE
BROWN
LIVE
NEUTRAL
EARTH
GREEN / YELLOW
BLUE
Max. wire 1 x 2.5mm per way
Load
Max. wire 2 x 1.5mm per way
Mains Supply
Isolation
Switch
E N L
Switch off the electricity at the fuse box by removing the relevant fuse or
switching off the circuit breaker before proceeding with the installation.
6. Installation Procedure:
1
Switch off the power.
230V
3
Drill and push the screw peg into the hole.
φ
6mm
*** IMPORTANT ***
2
Marking the screw hole.
4
Fix the U bracket to the wall.
Mounting Screws: (M4 x 32) x 2
Page 5
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
5
First, feed the cable through the rubber gasket of the junction box.
6
Attach the strain relief to the device and screw in.
4
EARTH
7
Tighten the screws.
Connect the individual wires to the appropriate terminal then tighten
9
Loosen the screws.
8
the screws.
10
Attach the wallplate to the device.
11
Attach the device to the U bracket then tighten the screws on both sides.
Screw: M3x12mm x 4
CONNECTION
( See connection diagram ) Connect the mains supply cable to the terminal block on the backplate as follows.
Connect the cable from the lighting load to the
terminal block on the backplate as follows.
LIVE
NEUTRAL
EARTH
LIVE
NEUTRAL
EARTH
12
Connect device to the mains. Unit goes into warm-up period for 40 sec.
Push
“click”
BROWN
BLUE
GREEN / YELLOW
BROWN
BLUE
GREEN / YELLOW
Page 6
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
1
8
0
1.8 TO 2.5 METER
12 METER
3 METER
Installation Advise:
WARNING
As the detector reacts to variations in temperature, avoid situations:
• Do not direct motion detectors at objects with highly-reflective surface
such as mirrors etc.
• Do not install motion detectors near heat sources such as heating outlets,
air conditioning system, lamps etc.
• Do not direct the motion detector at objects that move in the wind such
as curtains, large plants etc.
• Take account of motion direction during test run.
5
40
30
20
10
40
40
30
20
10
40
Detection Range:
LEDX30PIR: Recommended installation height is 2.5 meter above ground, the maximum detection range about 12 meter and at the angle of about 180 deg.
up to12m
2.5 METER
3 METER
12 METER
0
8
1
40
30
20
10
40
3m
180°
180°
Page 7
Walk Test and Adjustment
The purpose of Walk Test is used to test and adjust the detection coverage of
LEDX30PIR under auto mode.
Adjust the Time knob to minimum (fully anti-clockwise), then conduct a walk test as described in test procedure.
Test procedure:
Adjust the Time knob to (fully anti-clockwise), (Lux knob can be “Sun” or “Moon”).
Switch power on.
Walk across the detection area, once the detector is triggered and the lamp
will turn ON for 2 seconds.
Note walking direction when performing test.
Dusk Time
6
Test mode
Detector Head Adjustment
The detector head can be 90º turned left or right by hand and can be tilted
90º downward .
* Do not use the adjuster knobs to turn
the detector head.
2 sec
0
2
Sec
Pan left 90º
Tilt down 90º
Pan right 90º
Page 8
Knob Settings
LEDX30PIR has two adjustment knobs: Time and Lux at the bottom of the detector head.
Adjust knobs carefully with flat blade screwdriver.
TIME knob setting
You can set the time knob from 5 sec to about 10 min, LEDX30PIR will turn ON the lamp, for the time duration set after each detected movement.
Adjust the knob as desired.
LUX knob setting
• When setting the Lux knob at “MOON”, LEDX30PIR will only operate
in the dark.
When setting the Lux knob at SUN, LEDX30PIR will operate in any light level.
Adjustments
7 8
Dusk/Dawn
Environment lux level to turn On
Test mode
Turn On time adjustment
Time
10min5sec
0
5
sec
Dusk Setting (Time knob setting)
When setting the Time knob to fully clock wise, the motion detector of LEDX30PIR won’t function.
The lamp will operate depending on the “LUX” level, ie Dusk to Dawn..
0
Min
10
Page 9
Lamp turns
ON at night.
Setting Advise
WARNING
Lens masking
The purpose of the lens mask is to mask out areas not desired for detection.
Masking The Sensor Lens:
To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using the masking label provided. The top section of the lens covers long range detection, the bottom covers short range. Similarly the left and right lens sections cover the left and right detection areas respectively.
Page 10
Manual Override Mode:
The light can be switched on for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker single (OFF/ON) within 1 second. The unit will now illuminate continuously until dawn or until switched back into Auto Mode.
To switch the unit back into Auto Mode, switch the internal wall switch/circuit breaker once (OFF/ON) within one second. The unit will return to its Auto mode and will operate as set up after the walk test procedure.
Lamp Adjustment
The lamp can be tilted upward 45º and
tilted downward 60º.
9
WARNING
This product will get warm when in normal use. Can be installed on surfaces of normal flammability e.g. wood, plasterboard, brickwork and other masonry. Do not install on flammable surfaces such as plastics.
Tilt upward 45º
Tilt downward 60º
60 50 40
+40
30 20
-20
10
Page 11
Technical specications:
Energy Usage Lamp On Power Supply Power Factor Colour Temperature Colour Rendering Lumen Output initial Lamp Beam Angle
Detection Range Detection Angle Time On Adjustment Dusk Level Adjustment Environmental Protection EC Directives
Slave Output:
LEDX30FL LED lamp Halogen lamp CFL Fluorescent tube w/o PF correction
28kWh/1000h: 27.5W typ 230 V > 0.95 5000 - 5600K > 70 Black: 2115 Im typ, White: 2310 lm typ 110 x 100 degrees The lamps are not replaceable in this product Up to 12 metres 180º 5 seconds - 10 minutes Day & night or night only operation IP55 (suitable for indoor and outdoor use) Conforms to current EC Directives
Energy Efficiency Class A+
AC ~ 50Hz
Max. 10 sets Max. 10 sets with total 200W Max. 1000W Max. 15 sets 23W or Max. 345W Max. 648W
10
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to store.
Telephone the Timeguard Customer Helpline
Qualified Customer Support Co-ordinators will be on-line to assist
020 8450 0515
in resolving your query.
3 Year Guarantee
In the unlikely event of this product becoming faulty due
to defective material or manufacture within 3 years of the
date of purchase, please return it to your supplier in the
first year with proof of purchase and it will be replaced free
of charge. For years 2 and 3 or any difficulty in the first year telephone
the helpline on 020 8450 0515.
Note:
A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent.
Page 12
HELPLINE
020 8450 0515
or email helpline@timeguard.com
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Offi ce: 020 8452 1112
or email csc@ timeguard.com
67.058.503 (Iss.2)
Loading...