Timeguard LEDPROSLWH, LEDPROSLB Installation Instructions

Page 1
Dedicated PIR Professional
LEDPROSLB & LEDPROSLWH
I nst a l la ti o n & O p e ra t i ng In st ru ct i o n sI nst a l la ti o n & O p e ra t i ng In st ru ct i o n s
Ins t allation & O pera ting In s t r u c t ions
Page 2
These instructions should be read carefully and retained for further reference and
maintenance.
2. Safety
off.
3. Technical Specications
1
Dimensions
78
108
114
Page 3
12
TOP VIEW
SIDE VIEW
180°
A
B
Less
sensitive
Dusk Level
Adjust
Lens Sticker
C
Delay Time
Adjust
D
More
sensitive
Restrict Long
Detection
Restrict RHS
Detection
Restrict short
Detection
Restrict LHS
Detection
Page 4
E
3
Note:
Mains
Supply
Isolation
Switch
'Switch Live'
F
Page 5
4
4. Selecting The Location
angles as shown (see diagram A).
to maintain coverage and forward coverage will be reduced.
diagram A detailing detection range and direction.
may cause false activation under extreme conditions.
During extreme weather conditions the motion sensor may exhibit unusual behaviour. This
5. Installation
G
Page 6
*** IMPORTANT ***
Switch o the electricity at the fuse box by removing the
relevant fuse or switching o the circuit breaker
before proceeding with the installation.
Jumper Plug
Locking bar
5
CONNECTION
Connect the mains supply cable to the terminal block on the back plate as follows (see connection diagram):
EARTH (Green / Yellow) NEUTRAL (Blue) N LIVE (Brown) L
Connect the cable from the slave lighting load to the terminal block on the backplate as follows (see connection diagram):
bar with one
with the other
to reconnect).
EARTH (Green/Yellow) NEUTRAL (Blue) N SWITCH LIVE (Brown) L
Ensure that all connections are secure.
• Connect the 3 way PIR plug, by pushing the plug and socket inside the floodlight together until they lock. DO NOT FORCE. THE PLUG AND SOCKET WILL ONLY FIT TOGETHER ONE WAY AROUND (See Jumper Plug diagram).
• Secure the PIR to the luminiare using the 4 fixing screws supplied (see diagram G)
Page 7
6
6. Commisioning and Operation
Walk Test Procedure
The unit can be set up in daylight or at night.
seconds. This indicates the unit is wired correctly. The unit is in Automatic Mode when the light turns off.
Setting Up For Automatic Operation
setting between these limits.
each adjustment to try to get the unit to detect as above.
Page 8
7. Masking The Sensor Lens
sensor lens using the lens mask sticker supplied (see diagram D).
range. Similarly the left and right lens sections cover the left and right detection area respectively.
8. Manual Override Mode
17
procedure.
9. Detector Head Adjustment
The detector head can be panned 90˚ to the right and 90˚ to the left.
90˚
90˚
Tilt down
Page 9
10. Accessing Terminals After Installation
This may be necessary to add further lighting for instance and the following procedure for removing the unit from its backplate should be followed:­Insert the wire through the hole indicated in diagram F. The terminals are now accessible. If adding lighting, ensure the unit’s rating is not exceeded.
If you experience problems refer to Troubleshooting Guide.
If problems still exist,
do not immediately return the unit to store.
Telephone the Timeguard Customer Helpline
020 8450 0515
Qualied Customer Support Co-ordinators will be on-line to
assist in resolving your query.
8
11. Troubleshooting
PROBLEM SOLUTION
night and day.
night, or PIR keeps activation at random for no apparent reason
terminals may be transposed.
The unit may be suffering from false activation. Cover the sensor lens completely with black PVC tape. This will prevent the sensor from “seeing” anything. If the unit now switches off after the set time duration and does not re-activate, this indicates that the problem was cause by false activation. The problem may be solved by slightly adjusting the direction/angle of the sensor head (see previous section). If however, the unit
the unit is faulty and should be replaced.
Page 10
You may not be allowing the unit time to complete it’s warm-up period. Stand well out of the detection range and wait (the warm-up period
Sometimes passages between buildings etc. can cause a “wind tunnel” effect. Ensure the unit is not positioned so as to allow detection of cars/people using public throughfares adjacent to your property. Ensure that the unit is mounted securely, even the slightest movement can result in a false detection.
9
PIR sensor will not operated at all.
The PIR sensor will not
operate at night.
Unit activates during the daytime.
PIR coverage is poor/ sporadic.
Detection range varies from day to day.
breaker/internal wall switch.
UIT
wiring connections as per the diagram (see diagram E). Ensure no connections are loose. Check the bulb. If the bulb has failed, replace (do not hold bulb directly with fingers, use a tissue or clean dry cloth). Ensure that the bulb is seated correctly in the bulbholder.
Refer to section 4 for DUSK control adjustment.
Refer to section 4 for DUSK control adjustment.
Unit may be poorly located. See previous section-“Selecting The Location” and re-locate the unit.
PIR sensors are influenced by climatic conditioins. The colder the ambient temperature, the more effective the sensor will be. You may need to make seasonal adjustments to the sensor head position to ensure trouble-free operation all year round.
Page 11
10
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year, telephone the helpline on 020 8450 0515 .
agreed by Timeguard) the customer is responsible for all shipping/postage charges
is sent.
Page 12
If you experience problems, do not immediately return the unit
to the store. Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard. com
Qualied Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Offi ce: 020 8452 1112
or email csc@timeguard.com
www.timeguard.com