These instructions should be read carefully and retained for further reference and
maintenance.
2. Safety
switched off and the circuit supply fused are removed or the circuit breaker turned off.
installations of this system and install in accordance with the current IEE wiring and
Building Regulations.
3. Technical Specications
�7
1
Dimensions
����7
91
78
53
91
2
AB
,UXTime on
View on underside of unit shows adjustments
D
Mains
Supply
C
Note:
Switch Live terminal 'Live Output' will be
Isolation
Switch
Any floodlight connected to the L
'Switch Live'
3
4. Installation
*** IMPORTANT ***
Switch o the electricity at the fuse box by removing the
relevant fuse or switching o the circuit breaker
before proceeding with the installation.
Jumper Plug
Locking bar
Release clips
rating.
bar with one
hand, grip the
release clips
with the other
and pull (push
to reconnect).
Mains
Supply
Isolation
Switch
'Switch Live'
CONNECTION
Connect the mains supply cable
follows (see connection diagram ):
EARTH (Green / Yellow)
NEUTRAL (Blue) N
LIVE (Brown) L
Connect the cable from the slave lighting load to the terminal block on the
backplate as follows (see connection diagram):
EARTH (Green/Yellow)
NEUTRAL (Blue) N
SWITCH LIVE (Brown) L
4
(see diagram C).
to the terminal block on the back plate as
5. Operation and Testing
To Set the adjustment knobs as follows:See diagram A.
“ON”
Turning this setting fully clockwise allows you to test the circuit during daylight.
Connect the photocell to the mains and switch power on.
After a short delay, the unit will switch ON. This is indicated by the red LED see
diagram B. Any attached lights will also illuminate.
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to
Telephone the Timeguard Customer Helpline
store.
020 8450 0515
5
Qualied Customer Support Co-ordinators will be on-line to
assist in
resolving your query.
6. Troubleshooting
PROBLEM SOLUTION
The sensor will not
operate at night.
Unit activates during the
daytime.
The level of ambient light in the area may be too
bright to allow operation at the current DUSK
setting. During the hours of darkness, adjust the
DUSK control slowly clockwise until the lamp
illuminates. Refer to previous section for more
details.
Adjust the setting anti-clockwise to lower the level
of ambient light required for activatioin.
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or
manufacture within 3 years of the date of purchase, please return it to your supplier
in the first year with proof of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year, telephone the helpline on
020 8450 0515 .
Note: A proof of purchase is required in all cases. For all eligible replacements (where
agreed by Timeguard) the customer is responsible for all shipping/postage charges
outside of the UK. All shipping costs are to be paid in advance before a replacement
is sent.
6
If you experience problems, do not immediately return the unit
to the store. Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualied Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Offi ce: 020 8452 1112
or email csc@timeguard.com
TW – December 2022
www.timeguard.com
67.058.562 (issue 2)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.