These instructions should be read carefully
and retained for further reference and maintenance.
2. Safety
• Keep the RF Remote Fob clean and in a
good condition.
• Do not submerge the fob in water or use
in extremely damp or wet locations
• Do not use batteries other than those specified.
Dispose of them properly, observing environmental
12
protection rules.
3. Technical Specifications
• Battery: 3V (1 x CR2032
supplied)
• Battery Life: Approximately
24 months
(@ 10x opt/day)
• Class Rating: Class III
• Transmission and Receiving Distance:
100m hand held (clear line of sight)
10m when mounted inside a wall switch
(recommended mounting height = 1.2m)
• Total number of fobs usable per PIR: 6
• Operating Temperature: -20°C to +40°C
• RF Module: TX Transmitter
• RF Frequency: 433.72MHz
to 434.12MHz
• IP44 Rated: Suitable for restricted
external applications
• CE Compliant
23
• Dimensions (H x W x D) 60 x 38 x 15mm
• Compatible with the following
Timeguard PIR products;
SLB2300RF PIR Light Controller – Black
SLW2300RF PIR Light Controller – White
LEDPRORFKB RF Remote Kit – Black
LEDPRORFKWH RF Remote Kit – White
4. Battery
• To access the battery holder, remove the back plate
from the fob as shown in the diagram.
5. Pairing the RF Remote
34
Fob(s) with the PIR Light
Controller
Note: Please refer to the operating instructions that
came with the SLB-W2300FR or LEDPRORFKB-WH
products you are using, and ensure you have
completed the Walk Test Procedures before you
can pair the devices. The pairing of the fob(s)
cannot be actioned with a PIR light controller set
to Test Mode. Make sure the PIR light controller
is functioning correctly and set for Automatic
Operation (Auto Mode) before you continue.
• Press the centre button that is located on
the bottom of the PIR light controller once
(do not press and hold for longer than 4 seconds),
the lamp will flash twice to indicate it is ready
to pair your fob(s).
Note: once the lamp has flashed twice, the PIR
sensor will no longer trigger the lamp with motion
until the pairing sequence has been completed.
SLB-W2300RF Centre Button Location.
45
LEDPRORFKB-WH Centre Button Location
56
• Press the fob button once. The lamp will turn ON
for 3 seconds, and back OFF again, to indicate
it has been registered.
Note: If you have more than one fob to pair
(Up to 6 max) then press the fob buttons,
one at a time, waiting for the lamp to turn ON
for 3 seconds and back OFF again each time,
between presses. You cannot pair a 7th fob.
If attempted, the lamp will flash twice to indicate
it has not been paired.
• After the last fob press, wait for approximately
30 seconds until the lamp flashes twice.
This will indicate that your fob(s) have successfully
been paired.
Note: once the lamp has flashed twice, the PIR
6
light controller will begin to trigger with motion
once again.
• Test your fob(s) by pressing the fob button once to
turn the lamp ON, and once to turn the lamp OFF.
If you are using more than fobs, you are able to
turn the lamp ON using one fob, and turn the
lamp OFF using another.
6. Erase all RF Remote Fobs
from the PIR Light Controller
• Press and hold the centre button, located on
the bottom of the PIR light controller, for
approximately 5 seconds. The lamp will flash
5 times. This indicates that un-pairing has
been successful.
78
Remove
rubber caps
7. Installing a RF Remote Fob
into a Wall Switch
• Remove the rubber caps
from the bottom of the fob
as shown.
• Using 2 of the wires supplied,
89
push them firmly into the
2 spring clamp terminals.
Check they are both secure
with a light tug.
• Follow the wall switch wiring image for connection.
910
Dry Contact
w/o 230V AC Potential
3 Year Guarantee
In the unlikely event of this product becoming faulty
due to defective material or manufacture within
3 years of the date of purchase, please return it to
your supplier in the first year with proof of purchase
and it will be replaced free of charge. For the
second and third years or any difficulty in the first year
telephone the helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases.
For all eligible replacements (where agreed by
Timeguard) the customer is responsible for all
shipping/postage charges outside of the UK.
10
All shipping costs are to be paid in advance
before a replacement is sent out.
If you experience problems, do not immediately
return the unit to the store.
Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
www.timeguard.com
67.058.621 (Issue 1)
Zerofour – May 2018
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.