Timeguard LEDCST30PIRB, LEDCST10PIRB, LEDCST10PIRWH, LEDCST20PIRWH, LEDCST20PIRB Installation Instructions

...
LED Coastal Grade
PIR Floodlight
Model: LEDCST20PIRB (Black)
Installation & Operating Instructions
Model: LEDCST10PIRB (Black)
Model: LEDCST10PIRWH (White)
Model: LEDCST30PIRB (Black)
Model: LEDCST30PIRWH (White)
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC, 50Hz
• These luminaires are of class I construction and must be earthed
1 2
• Energy Efficiency: Class A
• Colour Temperature: 4000K
• IP55 Rated suitable for restricted external applications
• Detection Angle: 180°
• Detection Range: Up to 12 metres
• Time On Adjustment: 5 seconds to 10 minutes
• Dusk Level Adjustment: Day and Night or Night only operation
• CE Approved
LEDCST10PIRB-WH
• 10W LED Non replaceable lamp
• Energy Usage: 10Kwh/1000h
• Lumen Output: 750lm
LEDCST20PIRB-WH
• 20W LED Non replaceable lamp
• Energy Usage: 20Kwh/1000h
• Lumen Output: 1500lm
LEDCST30PIRB-WH
• 30W LED Non replaceable lamp
• Energy Usage: 30Kwh/1000h
• Lumen Output: 2250lm
Other Loads – External (Slave)
• Up to 10 sets of LEDCST10-20-30 Uncontrolled floodlights
• LED lamp: Max 10 sets with total of 200W
• Halogen lamp: Max 1000W
• Fluorescent: Max 15 sets 23W, or Max 345W
• Fluorescent tube w/o PF correction: Max 648W
Parallel Switching
• A maximum of 4 LEDCST10-20-30PIR floodlights can be wired in parallel to enable any detector to turn ON all the lights connected.
4. Installation Advice
2 3
As the detector responds to changes in temperature, avoid the following situations:
• Pointing the detector towards objects with highly reflective surfaces, such as pools of water or white-painted walls.
• Mounting the detector near heat sources, such as heating vents, air conditioning units, lights etc.
• Pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
up to 12m
3m
• Recommended installation height is 2.5m above ground, the maximum detection range about 12m and at the angle of about 180°.
3m
2.5m 3m
12m
12m
up to 12m
180°
5. Installation Procedure
3 4
5.1 Mark the position of the mounting holes on the wall using the U bracket supplied as a template.
5.2 Drill the holes for the wall plugs ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface.
5.3 Fix the U bracket to the wall using the correct screws for the wall plugs installed.
4
5.4 Secure the supply cable into the junction box through the hole(s) provided ensuring that a cable gland, grommet or sealing compound is used to maintain the IP rating of the luminaire.
5.5 Attach the strain relief to the luminaire and screw in ensuring not to over-tighten.
5.6 Terminate the supply cable into the terminal block (please refer to section 6 connection diagram) ensuring correct polarity is observed and that all bare conductors are sleeved.
5.7 Attach the supplied wall plate to the luminaire, apply pressure to catches located on top and bottom until all click into place to ensure the weatherproof seal.
5.8 Attach the luminaire to the U bracket fitted to the wall, then screw in on both sides ensuring not to over-tighten.