2x 10W LED Slimline
Floodlight – Twin Flood
Model: LED200FLBE – Black
Model: LED200FLWHE – White
Installation & Operating Instructions

1
1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire
is switched off and the circuit supply fuses are removed or the circuit breaker
turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this luminaire and install in accordance with the current IEE
wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted
does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50Hz
• This luminaire is of class I construction and must be earthed
• 2x 10W LED Non replaceable lamp
• Energy Usage: 20KwH/1000H
• Lumen Output: 2x 840lm
• Beam Angle: 90 x 90
• Lamp Adjustment Pan and Tilt: Wall Mount – Pan Outward 21° (limited by wall),
Pan Inward 45°, Downward 70°
Wall Mount with Spacer (sold separately) –
Pan Outward 40° (limited by wall),
Pan Inward 45°, Downward 70°
Inner Corner Bracket (sold separately) –
Pan Inward from 10° to 45° (limited by wall),
Downward 70°
Outer Corner Bracket (sold separately) –
Pan Outward 45°, Pan Inward 45°,
Downward 70°
• Colour Temperature: 4000K

• Operating Temperature: -20°C to +45°C
• Back Box Mounting Centres: 60mm
• IP55 Rated suitable for restricted external applications
• CE Compliant
• Dimensions: H= 160mm, W= 167mm, D= 50mm
2
4. Installation
4.1 Ensure the mains supply is switched off and the
circuit supply fuses are removed or the circuit
breaker turned OFF (See image 1).
4.2 An isolating switch should be installed to
enable the power to be switched ON and OFF
for maintenance purposes.
4.3 Disconnect the back box from the luminaire
by releasing the lugs (left or right side).
See Image 2.
4.4 Firmly grip the back box with your hand,
from top and bottom and carefully pull
away from the luminaire. See Image 3.
4.5 Mark the position of the mounting holes
on the wall using the back box as a template
(See image 4). Drill the holes ensuring not to
infringe with any gas/water pipes or electrical
cables that may be hidden below the surface.
Insert the rawl plugs into the holes. Pass the
230V 50Hz supply and load cables through the
cable entry points on the back box, ensuring
the grommets are used to maintain the
IP rating of the luminaire.
1
2
3
4