These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire
is switched off and the circuit supply fuses are removed or the circuit breaker
turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this luminaire and install in accordance with the current IEE
wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted
does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50Hz
• This luminaire is of class I construction and must be earthed
• 10W LED Non replaceable lamp
• Energy Usage: 10KwH/1000H
• Lumen Output: 840lm
• Beam Angle: 90 x 90
• Lamp Adjustment Pan and Tilt: Wall Mount – Left and Right 40° (limited by wall), Downward 70°
Wall Mount with Spacer (sold separately) – Left 210°, Right 45°, Downward 70°
Inner Corner Bracket (sold separately) – Left 210°, Right 45°, Downward 70°
Outer Corner Bracket (sold separately) – Left 90° (limited by corner), Right 45°,
Downward 70°
• Colour Temperature: 4000K
• Operating Temperature: -20°C to +45°C
• Back Box Mounting Centres: 60mm
• IP55 Rated suitable for restricted external applications
• CE Compliant
• Dimensions: H= 160mm, W= 80mm, D= 50mm
2
4. Installation
4.1 Ensure the mains supply is switched off and the
circuit supply fuses are removed or the circuit
breaker turned OFF (See image 1).
4.2 An isolating switch should be installed to
enable the power to be switched ON and OFF
for maintenance purposes.
4.3 Disconnect the back box from the luminaire
by releasing the lugs (left or right side).
See Image 2.
4.4 Firmly grip the back box with your hand,
from top and bottom and carefully pull
away from the luminaire. See Image 3.
4.5 Mark the position of the mounting holes
on the wall using the back box as a template
(See image 4). Drill the holes ensuring not to
infringe with any gas/water pipes or electrical
cables that may be hidden below the surface.
Insert the rawl plugs into the holes. Pass the
230V 50Hz supply and load cables through the
cable entry points on the back box, ensuring
the grommets are used to maintain the
IP rating of the luminaire.
1
2
3
4
4.6 Fix the back box to the wall using the 2 mounting screws, making sure
it is the correct way up. Take care not to over-tighten the screws to prevent
damage to the back box. If using a power screwdriver, use the lowest
torque setting. See image 5.
4.7 Terminate the 230V 50Hz mains supply cable into the terminal block
(See image 6) ensuring correct polarity is observed and that all bare conductors
are sleeved (See section 5. Connection Diagram – for wiring details).
5
34
4.8 Re-connect the luminaire to the back box
ensuring the 2 lugs firmly latch on the left
and right hand side, indicated by a ‘click’.
See image 7.
6
7
LN
230V~50Hz
MAINS SUPPL
L
E
N
SWITCH
5. Connection Diagram
ISOLATION
4
230V 50Hz Mains Supply
Live Supply (Brown or Red) to L
Neutral Supply (Blue or Black) to N
Earth (Green/Yellow) to
Y
6. Operation
• Turn the power on to the luminaire
and test for normal operation.
See image 8.
8
7. Lamp Adjustment
• Pan/Tilt adjustment including details when using the optional spacer and corner
brackets (sold separately).
56
6
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or
manufacture within 3 years of the date of purchase, please return it to your supplier
in the first year with proof of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year, telephone the helpline
on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements (where
agreed by Timeguard) the customer is responsible for all shipping/postage charges
outside of the UK. All shipping costs are to be paid in advance before a replacement
is sent.
If you experience problems, do not immediately return the unit
to the store. Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
Zerofour – June 2017
www.timeguard.com
67.058.579 (Issue 1)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.