Time Guard FST24, FST77 Installation & Operating Instructions Manual

Installation & Operating Instructions
Fused Spur
Time Switch
Model No. FST24 – 24 Hour Timer
Model No. FST77 – 7 Day Timer
1
Power LED
Sets time and date
Reset button
Illuminated screen
Output LED
Sets programmes
Double pole switch
BS 1362 (1"x
1
/4") fuse
Boosts for 1 or
2 hours and
decrements
displayed value
during time and
programme
setting
Override until
next programme
change and
increments
displayed value
during time and
programme
setting
1. General Information
Contents:
1x FST programmer Bag containing: 2x 3.5mm screws, 2x cable clamp set. 1x Instruction leaflet
The FST24 (24 hour) and FST77 (7 day) are units which mount onto a BS4662 flush mount single box, or a BS5733 surface mount single box, (25mm deep in either case). There is provision for a single front exit output cable, with built in cable clamp.
The unit combines the facilities of a time switch and a double pole switched fused connection unit capable of being wired directly into a ring main. The contacts are not volt free. There is a loop terminal for earth continuity. The unit has the option of automatic daylight saving pre-programmed in.
Fig. 1 FST24/FST77 Front Panel
2
2. Battery
The unit has an in built non replaceable, rechargeable battery, which will keep the programmed times during power down situations for up to 4 weeks. If the screen goes blank, once power is restored, and 4 hours have elapsed (to give a working battery charge), Reset must be pressed, and times/programmes re-entered.
Before programming for the first time, connect the unit to the mains for at least 15 minutes prior to pressing the Reset button and programming the unit. If the display is not visible or very faint, charge for 4 hours prior to pressing Reset and programming.
Supply live terminal
Switched
neutral terminal
(load neutral
connection)
Loop terminal
for earth
continuity
Supply neutral
terminal
Switched live terminal (load live connection)
3. Applications
Energy consuming appliances such as immersion heaters and storage heaters up to 13A total loading can be supplied by the FST24/77 enabling users to make use of economy 7.
If the user has other appliances which do not have push button start, such as washing machines, dishwashers and tumble dryers, these may also be controlled in the same way. It can also be sued to control lighting, if a neutral is made available. Lighting loads can be found in the specification section of this leaflet.
Fig. 2 FST24/FST77 Rear Connections
3
4. Features
5. Installation
4 On/OFF switching programmes per day. Which for the FST77 can be made to operate over all 7 days (24 hour operation), 5 weekdays 2 weekend days, or any individual day (7 day operation). For FST24, 5+2 and individual day programming are not available, all 7 days are the same.
Advance feature, which can advance to next programmed operation, turn output permanently on, turn output permanently off, or return to programmed times.
Boost feature provides 1 or 2 hour boost.
Option of automatic summer time update (ASCO).
Shortest switching time of 1 minute.
Programme review.
Important: Switch off mains electricity before commencing work.
The unit is designed to replace an existing single gang connection unit or fixed appliance outlet giving timed mains output, protected by a BS1362 fuse. The unit is capable of forming part of a ring main (the terminals can accept 2 x 2.5mm sq. cables) or terminating a spur off the ring main. The unit requires a minimum depth of 25mm within the box.
Ensure that the wiring is adequate for the load to be carried. Connect incoming and outgoing cables to the relevant terminals. Secure the unit to the back box with the
3.5mm screws provided, forming cables during installation to avoid entrapment and cable damage.
Use the loop terminal, or the earth terminal in the back box for earth continuity if required. If installed into a metal back box, earthing of the back box is required.
There is a removable cable blank to cover the front cable exit if this feature is not required. If the front cable exit is required, for instance to connect to a washing machine, use one of the cable clamps provided to secure the outgoing cable.
Loading...