Timeguard DS3HDN Installation Instructions

IP65 Time Delay Switch
Model: DS3HDN
Installation & Operating Instructions
1. General Information
These instructions should be read carefully and retained for further reference and maintenance.
2. Safety
• It is recommended that a qualified electrician is consulted or used for the installation of this time delay switch and install in accordance with
1
the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this time delay switch is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This time switch is of class I construction and must be earthed
• Switch Rating: 16A Resistive (4kW)
The LED switching capabilities of this
product can be increased up to 200W by the addition of the Timeguard
2
ZV900 Automatic switch load controller – Sold separately.
• Boost Timing Range: 2, 5, 10, 30, 60, 90, 120, 180 minutes
• Illuminated Push Button: Blue LED
• Operating Temperature: -10°C to +40°C
• IP Rating: IP65
• CE Compliant
• Dimensions (H x W x D): 94 x 94 x 57mm
Note: Not suitable for use with
Discharge Lighting
Filament Lamps 4kW Fluorescent 4kW Low Voltage 20-200W LED Lighting 150W
Figure 1 – front panel of DS3HDN
3 4
Four fixing holes
Mains supply input and output connector
Four fixing holes
Figure 2 – internal of DS3HDN
Four PCB mounting screws
Push button
switch
connector
Time delay
selector