1. Introduction
The DCEX3/DCEX4 Door Entry System enhances entry security by enabling the user to recognise the visitor by audible and visual means before opening the door.
An electric door catch (not supplied) is available as an optional extra for the DCEX3/DCEX4 to make the door opening automatic.
The external and internal intercoms are connected by a two core cable. With the cable supplied the distance between these units is limited to 15m. By using 13/0.2 bell cable this distance can be increased to a maximum of 70m.
2. Product Overview
If operation with an electric door catch is required then part DCLR is a fail (power off) secure catch available from Timeguard. See fi g 2 for wiring of this part. An additional two core cable run (using 13/0.2 bell fl ex) will be required between internal intercom and door catch.
Fig 1a - External Intercom (front view) DCEX4 shown
1
3
Fig 1c - Internal Intercom (side view) and remaining parts
14
NAME PLATE
NAME PLATE
Fig 1b - Internal Intercom (front view)
4
6
17
15
2
1. External intercom.
2. Internal intercom.
20
5
3. Name plate.
4. Loudspeaker.
5. Power on indicator.
6. Ring button.
7. Keyhole xing.
12
13
8. Screw terminals.
9. Slot for angle bracket (15).
10. RJ-11 plug.
11. Mains adaptor low voltage socket.
12. Speak button.
13. Door open button.
14. Mains adaptor.
15. Angle bracket.
10
HI
LO
1 2 3
16. Volume switch (Hi/Lo).
16
17. Connecting cable.
19
18. RJ-45 socket.
19. Ring tone selector.
20. Quiet observation button.
Fig 2 - Wiring diagram
DCEX3 (single channel)
Internal intercom
11
18
Alternative low voltage supply connection
DCEX4 (twin channel)
External intercom
Door catch
8
Alternative low voltage supply connection
Door catch