Timeguard DCA2 User Manual

AUDIO DOOR ENTRY SYSTEM
Model: DCA1 Single Channel
DCA2 Twin Channel
DCA1/2
INSTALLATION & OPERATING INSTRUCTIONS
DCA1DCA2
1. Introduction
The DCA1/DCA2 Door Entry System enhances entry security by enabling the user to recognise the potential entrant by audible means before opening the door.
An electric door catch (not supplied) is available as an optional extra for the DCA1/DCA2 to make the door opening automatic.
The DCA2 external intercom has the ability to call separately located internal intercoms for two individual dwellings with a common entrance. The DCA1 calls one.
Connecting cables between component parts are all 2 core, so existing bell fl ex can be used to connect the internal and external units if desired.
2. Overview
If operation with an electric door catch is required then part DCLR is a fail (power off) secure catch available from Timeguard.
1
Fig 1 Component parts
of Single Channel system.
10
1. External intercom (1 channel shown)
2. Internal intercom
3. Mains adaptor
4. 15m of 2 core connecting cable
5. Cable terminals
7. Ring button
8. Ringtone volume adjust (2 position switch)
9. Door open button
10. Mains adaptor low voltage plug
Internal intercom (fi rst channel)
External intercom
(DCA2 shown)
Handset cable
Internal intercom (second channel)
Handset cable
Electric door catch
(not supplied)
Fig 2 Wiring diagram for Two Channel system.
6. Terminal strip
11. Mains adaptor socket
12. Internal intercom mounting hole
13. Cable channel
Note: For single channel operation ignore second channel internal intercom and its 2 core connecting cable to terminals 3 and 4 on the external intercom.
2
3
3. Selecting intercom sites and cabling
3.1 Intercom sites
The internal intercom should be located at a convenient position for all potential users at the height indicated in fi g 3a and at a maximum distance of 70m from the external intercom. If all the users are signifi cantly above or below average height then a different mounting height may be considered appropriate.
The external intercom should be sited in an area away from driving rain and surface water, out of direct sunlight as far as possible and protected by the minimum of an open porch in a position readily accessible to potential entrants. It should be mounted at the height indicated in fi g 3b.
50cm
75º
165 cm
165 cm
Fig 3a
Internal intercom
mounting height
Fig 3b
External intercom mounting
height and coverage