These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire
is switched off and the circuit supply fuses are removed or the circuit breaker
turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this luminaire and install in accordance with the current
IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted
does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This Luminaire is of class II construction and must not be earthed
• IP44 Rated suitable for restricted external applications
• Beam Angle: 120°
• Operating temperature: -10°C to 40°
• CE Compliant
2
4. Installation
1. IMPORTANT Switch off the electricity at the fuse box by removing the
relevant fuse or switching off the circuit breaker before proceeding with
the installation.
2. An isolating switch should be installed to switch the power to the unit
on and off. This is for maintenance purposes.
3. Unscrew the security nuts located on the front of the unit.
4. Pull away the back plate from the wall mount.
5. Separate the terminal block and back plate by using a flat head screw driver;
do not disconnect any pre-installed cables.
Lamp Holder
Seal Ring
(Gasket)
Wall Mount
Terminal Block
Pre-Installed
Cable
6. Using the back plate as a template mark the position for the holes.
Note the back plate must be mounted in the correct orientation,
following the ‘UP’ arrow.
7. Drill the wall using a 6mm Ø masonry drill bit making sure not to infringe
or compromise any gas, water pipes or cables. Insert the supplied rawl plugs
into the previously drilled holes.
8. Pierce the pre-installed rubber grommet and pass through the 230V AC 50Hz
mains supply cable. Ensuring the IP rating of the fitting is maintained
(Silicon sealant may be used).
9. Secure the back plate to the wall using the screws provided ensuring
that the machine threaded bolts are in place and the back plate is correctly
orientated (Arrow Up).
Seal Ring
(Gasket)
Back Plate
Machine
Threaded Bolts
10. Reinstall the terminal block to the back plate ensuring it is clipped
in place securely.
11. Using the standalone connection diagram (see section 5.Connection Diagram)
connect the 230V AC 50Hz mains supply cable to the terminal block ensuring
that all bare conductors are sleeved and that correct polarity is observed.
Terminal Block
Mains Supply Cable
(230V AC 50Hz)
Back Plate
34
12. Align the holes in the lantern wall mount with the machine threaded bolts
13. Align the housing to the wall mount joint. (There are two rounded tabs and
14. Twist the body approximately 30 degrees clockwise to lock in place.
15. Fit the 4 watt candle lamp supplied into the lamp holder moulded
20mm Grommet
in the back plate and push the wall mount over the back plate.
Secure with the security nuts.
one triangle tab on the wall mount to ensure the housing is correctly in place.
Please note gaskets are already applied to the required parts.
to the wall mount.
Fixing Holes
16. Place the six pieces of glass into the housing accordingly, take great care
in fitting the glass as the edges may be sharp.
17. Mount the lid on top of the housing and twist clockwise until secure,
the rectangular tabs on both the lid and top part of the housing
will indicate where the lid fits in place.
18. Attach the end cap to the top of the lid and twist clockwise until firmly
locked into position again using the same method as the wall mount with
the two rounded tabs and one triangular tab and twist clock wise.
4
Inverted Housing
Configuration
Interlocking feature for
the end cap/as well as the
wall mount.
Note: on this model you can
invert the wall mount to
be placed above as well as
below the housing as there
is no PIR.
5. Connection Diagram
6. Operation and testing
56
• Turn the power to the unit on, and the unit will illuminate.
6
3 Year Guarantee
In the unlikely event of this product becoming faulty due to defective material or
manufacture within 3 years of the date of purchase, please return it to your supplier
in the first year with proof of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year, telephone the helpline
on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible replacements (where
agreed by Timeguard) the customer is responsible for all shipping/postage charges
outside of the UK. All shipping costs are to be paid in advance before a replacement
is sent.
If you experience problems, do not immediately return the unit
to the store. Telephone the Timeguard Customer Helpline;
HELPLINE
020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Co-ordinators will be on-line
to assist in resolving your query.
For a product brochure please contact:
Timeguard Limited.
Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
Zerofour – April 2016
www.timeguard.com
67-058-522 (Issue 2)