Time Electronics 7000 Specifications

Time Electronics
7000 RTD Temperature Calibrator
DESCRIPTION
• Temperature accuracy 0.05°C (0.09°F)
• Temperature resolution 0.01°C (0.02°F)
• Resistance accuracy 0.03Ω
• 2, 3, and 4 wire connections
• Measure and simulate °C, °F, °K, & Ω
• Ramp and step
• PT100 plus 7 other RTD types
• User programmable
SOFTWARE
• 24 hours typical use between charges
The 7000 is a portable process control instrument that combines a precision digital thermometer (using RTD probes) with an RTD/ohms calibrator.
Compact and easy to use, it solves the problem of making high accuracy temperature measurements without using bulky mains powered instrumentation. Powered from internal long life rechargeable batteries or an external mains
adaptor, it is equally valuable in laboratory, workshop or the eld. It can also be used as an external temperature
reference for dry block and other precision temperature baths.
MODES OF OPERATION
Monitor Mode (4 wire)
Typical Functions ................................ 1. Check RTD probes by measuring their resistance at known temperatures.
............................................................. 2. Measure resistance values.
............................................................. 3. Indicate temperature when connected to an RTD probe.
............................................................. 4. Can be pre-programmed with a particular RTD’s characteristics to allow very high accuracy.
Excitation current ................................ 1mA on all ranges
Resistance range ................................ 0.01Ω to 2.6kΩ
Resolution ........................................... 0.01Ω
Accuracy ............................................. See specications on next page
Auto re-calibration ............................... Every 0.6 secs.
Temperature stability ........................... Better than 0.0015% per °C
Max/Min values ................................... Logged automatically
The 7000 may be used with a calibrated and certified probe to produce a highly accurate thermometer. The performance can be further enhanced by programming the actual characteristic of the probe into the unit.
Simulator Mode (4 wire)
Typical Functions ................................ 1. Output resistance of precise known value.
............................................................. 2. Simulate an RTD value from an RTD table chart.
............................................................. 3. Simulate an RTD value using the internal table.
Excitation current ................................ 0.6mA to 1mA
Resistance range ................................ 0.01Ω to 2.6kΩ
Resolution ........................................... 0.01Ω
Accuracy ............................................. See specications on next page
Auto re-calibration ............................... Every 0.6 secs.
Temperature stability ........................... Better than 0.0015% per °C
Enhanced performance may be achieved by programming the unit to simulate the characteristic of a particular probe.
Five fixed step points (0, 25, 50, 75, 100%) are available between a user set minimum (0%) and a maximum (100%). Programmable ramp function is also available.
www.timeelectronics.com
7000 Specifications
TECHNICAL SPECIFICATIONS
Standard RTD types (Non standard RTD types user programmable)
Element Alpha Coefcient Temp Range °C Accuracy °C Temp Range °F Accuracy °F
Pt100 DIN 0.003850
Pt100 US 0.003916
Pt200 DIN 0.003850 -200 to 300 0.05 -330 to 570 0.10
Pt500 DIN 0.003850
Pt1000 DIN 0.003850
Ni 120 0.006180 -100 to 200 0.05 -150 to 390 0.10
Ni 1000 0.006180 -100 to 200 0.05 -150 to 390 0.10
-200 to 250 0.05 -330 to 480 0.10
250 to 849 0.07 480 to 1560 0.14
-100 to 250 0.05 -150 to 480 0.10
250 to 457 0.07 480 to 850 0.14
-200 to 250 0.05 -330 to 480 0.10
250 to 630 0.07 480 to 1160 0.14
-200 to 250 0.05 -330 to 480 0.10
250 to 630 0.07 480 to 1160 0.14
Resistance Accuracy
Range ohms Monitor Generator
20 to 400 0.03Ω 0.03Ω
400 to 800 0.10Ω 0.10Ω
800 to 1200 0.20Ω 0.20Ω
1200 to 2600 0.50Ω 0.50Ω*
*plus additional error of 0.05% of output value. If excitation current is less than 1mA.
GENERAL SPECIFICATION
Operating temperature range ............. -10 to 50°C
Battery power ...................................... NiMH rechargeable
Mains power ........................................ External mains adaptor
Battery life ........................................... > 24hrs typical use
Case .................................................... Impact resistant ABS
Dimensions ......................................... H165 x W90 x D45mm
Weight ................................................. 0.42kg
Optional Extras .................................... Mains Adaptor 230V AC, Mains Adaptor 110V AC
............................................................. Calibration Certicates – traceable to NPL and UKAS
ORDERING INFORMATION
7000 .................................................... RTD Temperature Calibrator
7633..................................................... Mains Adapter 230V AC
7633..................................................... Mains Adapter 110V AC
C183 .................................................... Factory (NPL Traceable) Calibration Certicate
C194 .................................................... UKAS Calibration Certicate (ISO 17025)