Outlook of devices, aslo colour scores can be revised without any special advance
notices.
Производитель вправе менять внешний вид прибора и цветовую гамму прибора без специального уведомления.
Электрический
увлажнитель
воздуха
Модели/Models:
Цвета \ Colors *
* - Указано в дополнительной маркировке модели \ Specified
in the additional marks of modes name
- Цвета для всего изделия и/или ряда его частей \ The colors
for the whole unit and/or its parts
Electric
humidifier
THU UL 09
(W) - белый \ white
(BL) - черный \ black
(O) - оранжевый \ orange
(BU) - синий \ blue
(LD) - декор «светлое дерево» \
light wood decor
(DD) - декор «темное дерево»\
dark wood decor
(CR) - декор «черный карбон» \
black carbon decor
www.timberk.com • electric humidifier
CONTENTS
1. Important information
2. Safeguards
3. Specification
4. Appliance description
5. List of parts
6. Filling of tank with water
7. Appliance operation
8. Cartridge filter for water softening
9. Cleaning and maintenance
10. Troubleshooting
11. Transportatiom and storage
12. Utilizatione
Dear customer!
2
3
4
5
5
5
6
6
7
7
8
8
We thank you for your happy choice! You’ve bought an air
humidifier Timberk. It will serve you for a long time. Please, read
this manual carefully before operating the device!
Humidifier is used to raised relative humidity level up, improving
microclimate. It helps to eliminate problems connected with
low air humidity.
1. IMPORTANT INFORMATION
The manufacturer reserves the right to make modifications in design,
configuration or manufacturing process of the device in order to improve
its properties.
There may be some misprints in the text and digital notations of this manual.
If you have any answers concerning operation of the appliance after you’ve
read the manual, please, apply to a shop assistant or to a specialized
service center for explanations.
The article has a label showing all the necessary specification data and
other useful information about the appliance.
Use the appliance only for its intended purpose indicated in this manual.
The humidifier is designed for air humidification indoors.
Relative air humidity for comfortable conditions should be between 40 and
60%.
Insufficient air humidity results in exsiccation of mucous membranes,
which in turn causes decrease in immunity, headache, cracking of lips,
sandpaper in the eyes, favors infection and respiratory tract diseases,
promotes exhaustion, leads to increased fatigue of eyes and decline of
attention concentration, has an adverse effect on pets and house-plants,
leads to the growth of dust formation and increase of electrostatic charge
of synthetic textiles.
2
www.timberk.com • electric humidifier
2. SAFEGUARDS
Before startup of the humidifier, please, study this manual carefully and
keep it for further use.
While using the appliance, it is necessary to observe some precautions.
Improper operation due to disregard to precautions may result in personal
injury of user or other people, as well as to damaging of their property. The
humidifier is designed for work in habitable rooms with observation of the
stated operation conditions. Using of the humidifier not for its intended
purpose may create situations dangerous to life and health. The electric
appliance, while in operation, should be under supervision, especially if it
is used in a room with children. The appliance is not intended for use by
persons (including children) with physical, sensory or mental disabilities,
or having insufficient experience and knowledge, if they are not under
supervision and did not receive instructions for use of the appliance from a
person responsible for their safety. Please, make sure that children do not
play with the appliance.
Use the appliance only in accordance with the user’s manual.
Never use the humidifier with a damaged power cord or plug and if the
humidifier is broken or damaged by falling or in other circumstances. The
humidifier should be operated only in the fully assembled condition. To
avoid a burn, do not touch a membrane of the operating humidifier (for
ultrasonic models). High frequency of oscillations results in heating of
the membrane. High-frequency oscillations of the ultrasonic humidifier
membrane are noiseless and safe for people and pets.
To avoid the electric shock, the damaged power cord should be replaced
only in authorized service centers by qualified specialists.
To avoid the electric shock, do not place the power cord near heating
appliances and inflammable or combustible materials.
To avoid traumas and property damage, do not try to repair the humidifier
by yourself.
Unplug the humidifier in the following cases: before discharge or filling of
a tank with water; before cleaning and maintenance; before assembling/
disassembling of elements; before displacement of the humidifier.
Install the humidifier on flat dry surface.
Outgoing steam may damage exposed surfaces. Do not install the
humidifier on the floor, as well as in close proximity to heating appliances,
walls, furniture and other objects.
The manufacturer and vendor are not responsible for damages caused by
incorrect position of the humidifier.
The humidifier should be installed on a rise – e.g. on a table, pedestal, etc
at the distance of not less than 60 cm from the floor and not less than 10
cm from the wall..
Never fill the water in the humidifier through a diffuser.
Do not immerse the humidifier in water or other liquids.
Do not install the humidifier in a passage or in other places, where it can be
touched, overturned, etc.
If the humidifier is not in use, unplug it. Do not lay a power cable under a
carpet or other objects. While placing the humidifier, be careful that you
do not touch the power cable by accident. Do not use the humidifier in
damp rooms.
Prevent the ingress of foreign objects into the humidifier.
Do not block an air intake and the diffuser with foreign objects.
Do not sit or stand on the humidifier and do not put heavy objects on it.
Excessive room humidity may cause water condensation on windows and
furniture. If this is the case, turn off the humidifier.
To avoid the damage of the humidifier, do not mix the water used for
humidification with essential oils, preservation agents, flavouring materials
and other foreign substances. The manufacturer and vendor are not
responsible for damages of the humidifier caused by nonfulfillment of this
requirement.
While unplugging the humidifier, do not pull the power cable and do not
touch it with wet hands.
3
www.timberk.com • electric humidifier
3. SPECIFICATION
Table 1
Technical specifications
Humidification capacityml/h180
Supply voltageV/Hz~220/50
Tank volumel1.8
Rated power consumptionW16
Nominal currentА0,08
Moisture protection class rating-IPX0
Electrical protection class rating-ll
Appliance dimensions, mmmm260x155x244
Package dimensions, mmmm300х205х285
Net weightkg1,25
Gross weightkg2,0
Recommended floor spacem
The manufacturer reserves the right to change the set-list of the device
(including liquid and powder components) for different supplies without
prior notice. The changes either in no way influence the basic technical
parameters of the device or may improve them, and also not violate the
legislation or quality standards of the countries of manufacture, transit and
selling.
The changes in the set-list may result in changing of the weight and
dimensions of the device, but not more than by +\- 5-20% (depending on
the product category)
Unit of
measurement
2
Value
20-25
4. APPLIANCE DESCRIPTION
Fig. 1
4
www.timberk.com • electric humidifier
1.Mist nozzle
2.Water tank handle
З.Power cord and plug
4.Air outlet
5. Water reservoir backlighting and air ionization function switch
6.Base
7.Aroma capsule
8.Water tank
9. Water reservoir cover with a valve
10. Water filter
11. Ultrasonic transduser
12. Water reservoir backlighting lamp
13. Device operation lamp
14. On- and -Off and steam escape intensity controller
5. LIST OF PARTS
1. Air humidifier – 1
2. User’s manual - 1
З. Guarantee slip - 1
4. Package - 1
5. Water filter -3
6. FILLING OF TANK WITH WATER
When moving the humidifier you should hold the humidifier by the base.
Remove the water tank from the device.
1. Grab the tank handle and pull it upwards.
2. Unscrew the tank cap counterclockwise (9).
3. Fill the tank with water.
4. Screw the tank cap clockwise (9)(pic. 1).
Make sure the tank cap is securely tightened. Be sure that the rubber
gasket is installed to the tank cap. Securely tighten the cap clockwise.
Incomplete fulfillment of the abovementioned measures causes the air
coming into the water tank and, as a result, a failure.
5. Install the tank to the device.
IMPORTANT!
Treated tap water is best suited for the unit, use an
ordinary domestic water filter. It is necessary to increase
the unit’s life cycle, as well as to eliminated generation
of white sediment around the unit. When using untreated
water they are released together with steam and settle
on the surrounding objects and surfaces. Though these
substances are considered safe for people, in large
quantities they may have harmful effect on furniture.
To avoid electric shock, prior to disassembling the unit
(removing the tank), disconnect the unit from the power
line! Do not fill the tank with other liquids but tap water.
Different composition of liquids has harmful effect on
internal parts and causes failures.
Do not fill the unit or the water tank with such additives
as essential oils, fragrances, cleaning agents, chemical
medical drugs, warm water (above 40°), etc.
Otherwise, the water tank and internal parts of the unit
will be damaged and inoperable.
Do not fill water directly into the internal part of the unit
or the atomizer.
Water inside the unit may cause failure of the unit.
5
www.timberk.com • electric humidifier
7. APPLIANCE OPERATION
- On/ Off
- Maximum capacity
- Night mode
- Water reservoir backlighting and air ionization function switch
Switching on/off, control of steam escape intensity
Plug the appliance. Before that, fill the tank with water. Turn the on-and-off
and steam escape intensity controller to the right ( ).
The appliance will switch on, the indication light will flash and steam will
come out from the diffuser. In the very beginning of this operation the
diffusion level may be unstable, which is caused by temperature difference
and water quality. Stabilization of this process will take a short time.
Turning the controller to the right and to the left, you may control the steam
intensity. Higher intensity of steam escape results in stronger and faster air
humidification.
Night mode
To choose the night mode set the turn on / turn off and steam outflow rate
controller to the position « »
In night mode the device operates with less noise and intensity. Depending
on the ambient temperature, humidification capacity may vary from 80 to
100 ml/h
Relative air humidity for comfortable conditions should be between 40
and 60%. You may define a favourable humidity level on the basis of your
own feelings or use a special device - hygrometer*, measuring a relative
humidity level.
To enable or disable the ionizer press the appropriate button (5).
The ionizer generates negative ions (anions) and refreshes the air in the
room. Anions strengthen the nervous and circulatory systems, improve the
lungs and provide effective protection against respiratory illnesses (such as
asthma and pneumonia). Anions purify the air of dust and smoke.
Air flavouring
The appliance is equipped with a chamber for aromatic oil. When the
aromatic oil is added, the air will be flavoured. Aromatic oil is not included
in the delivery set.
Automatic cut-out in the absence of water
Upon fall of water level in the reservoir lower minimum allowed the ultrasound
membrane of the device cuts out automatically. The red detector lights up
on the control panel. To continue the device functioning it is necessary to
fill the reservoir with water in accordance with the paragraph 5 Filling the
reservoir with water (pic. 1), then connect the appliance to the power line.
Note!
Disconnecting the appliance from the power line when it automatically
switches off due to no water is mandatory.
USEFUL INFORMATION!
Dear Customer,
When using the air humidifier, you may come across
condensate formation on its upper part and things
beside it, including water accumulation, which is not
a defect, but a feature of this model due to its unique
design. This feature may be related to several causes,
specified in the table 2 on page 7.
8. СARTRIDGE FILTER FOR WATER SOFTENING
The delivery set includes three cartridge filter with balls of mineral stone,
which has a strong absorption properties. Filter disinfects water, absorbs
the elements of heavy metals such as lead, chromium, mercury, zinc, etc.
Restores the normal acidity of the water (PH).
Filter service life is 4-6 months, depending on the quality of water used and
the frequency of use of the device.
If white marks appear on objects around the moistener, when the air
humidifier is used, this may be caused by the following:
1. Used water contains much magnesium or calcium. It is necessary to use
water pretreated in a household water filter or distilled water removing the
filter beforehand.
2. Remains of calcium and manganese salts accumulated inside the
appliance. It is necessary to clean the appliance inside.
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.