Руководство по эксплуатации включает в себя гарантийный талон
Outlook of devices, aslo colour scores can be revised without any special advance
notices.
Производитель вправе менять внешний вид прибора и цветовую гамму прибора без специального уведомления.
Electrical
storage water
heater
SWH FEL1 30 V
SWH FEL1 50 V
SWH FEL1 80 V
SWH FEL1 100 V
TABLE OF CONTENTS
1. Important information
2. Precautions
3. Application f water heater
4. Performance parameters
Technical characteristics
Dimensional features
5. Water heater description
6. Delivery set
7. Water heater installation
Location
Water heater mounting methods
Water heater mounting
Connection to water main
Connection to electric mains
8. Water heater control
Control panel
Water heater operation
9. Maintenance
10. Troubleshooting
11. Wiring diagram
12. Disposal
13. Serial number and production date
Dear customer!
Thank you for your good choice. You purchased TIMBERK
2
electric storage water heater with an enameled internal tank. It
will serve you for a long time!
3
3
TIMBERK electric storage water heaters will provide a lot
of hot water and will automatically maintain the specified
3
temperature. They are perfect to provide hot water for country
4
houses, cottages, baths and other standalone amenity rooms.
4
5
5
5
5
Please, read this operation manual carefully prior to use of the water heater.
6
This operation manual contains important information regarding your
6
safety, as well as recommendations on the proper operation of the unit and
7
its maintenance.
8
Save this operation manual together with the guarantee card, cash register
receipt, if possible, cardboard box and packing material.
9
Different types of this device are described in this manual.
9
The purchased water heater can slightly differ from the one, described in
9
the manual, but that doesn’t affect methods of its use and operation.
10
11
11
12
12
1. IMPORTANT INFORMATION
IMPORTANT!
Important precautions and instructions, contained in
this manual, do not account for all possible modes and
situations to be encountered. It is vital to understand
that common sense, caution and thoroughness are the
factors that are impossible to be built-in in any product.
These factors must be taken into consideration by
a person, interested in proper operation of the unit.
The manufacturer does not bear any responsibility in
case when the unit or its parts are damaged during
transportation, as a result of improper installation,
voltage fluctuations, as well as if some part of the unit
was altered or modified.
2
www.timberk.com • electrical storage water heater
2. PRECAUTIONS
A number of precautions is to be observed upon operation of the fan heater. Improper operation as a result of ignoring precautions may harm health
of the user and other people, as well as damage their property.
1. Any electrical appliance must be supervised when in operation, especially if there are children nearby. Make sure children do not touch the appliance.
2. Prior to installing the water heater, not connecting it to electrical main,
check and make sure the outlet for the water heater has a ground pin and
if it is properly earthed. If there is no earth circuit in your electrical main then
operation of the water heater is dangerous for your life.
3. Connect the water heater only to 220~/50V, Hz main. If necessary, find
out parameters of your mains at power suppliers.
4. To prevent overheating and risk of fire, as well as damage of internal
electrical main, do no modify the power cord’s length and do no connect
the water heater through electrical extenders.
5. It is forbidden to switch on the water heater if it is not filled with water or
if water cannot go through a pressure safety valve.
6. Never use the water heater if it is broken.
7. Do not remove the water heater cover when it is in operation.
8. Immediately unplug the water heater from electrical main if strange
sounds, odor or smoke are coming from it.
9. Always unplug the water heater from electrical main during a thunderstorm.
10. Prior to cleaning and maintenance of the water heater unplug it from
electrical main. Cleaning and maintenance must be performed in compliance with instructions of this operation manual.
11. Do not use hazardous chemical substances to clean the water heater
and prevent their contact with the appliance.
12. To prevent electrical shock the damaged power cord must be replaced
only in manufacturer’s authorized service centers by qualified specialists.
13. To prevent electrical shock do not place the power cord nearby heating
devices and flammables or combustibles.
14. Do not press buttons on the control panel of the water heater and its
remote controller (for some models) otherwise but by your fingers.
15. Since temperature of water in the water heater can reach +75°C, when
it is in operation you should not place your body parts under hot water at
the first run.
To prevent burns you should adjust the temperature of the discharging
water.
16. Do not use the water heater for purposes not specified by this operation manual.
17. Do not use the water heater in an explosive or corrosive environment.
Do not store gas and other volatile flammable liquids next to the appliance
– it is very dangerous!
18. It is forbidden to make alterations in the design of the water heater or
modify it.
19. Any service operations must be performed by a specialized organisation and qualified specialists. Improper installation may cause voiding of
guarantee maintenance.
20. The water heater is not intended for use by children and persons with
reduced physical, sensory or mental capabilities, or a lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by an individual responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance.
3. APPLICATION OF WATER HEATER
Electric water heater is used to heat cold water from water supply. Unit is
for household use.
4. PERFORMANCE PARAMETERS
1. Completely automatic control: automatic water heating, continuous automatic water temperature control.
2. DROP Defense – leakage protection and protection against surplus pres-
sure within a tank (pressure safety valve).
HOT Defense – two-stage overheating protection (thermostat and temperature limiter).
ALL PROTECTION SYSTEMS ARE RELIABLE AND SAFE.
3. Pipes of heating elements are designed taking into account high heat load:
safe and reliable, with an increased service life.
4. NON CFC urethane foam insulation of increased thickness: excellent heat
www.timberk.com • electrical storage water heater
3
insulation that allows to efficiently retain accumulated heat and save energy.
5. Temperature controller: accurate and reliable water temperature control.
6. FEL1 models equipped wiht temperature display shows current water
temperature in water heater tanks.
7. Internal tanks and all internal components are made out of SUS 304 stain-
less steel with walls 1.2 mm thick.
8. The water heater is equipped with an anode bar to protect the internal
tank from corrosion and decrease scale generation on the heating element.
Technical characteristics
Technical characteristics of water heaters are given below in Table 1, 2.
Table 1
Description Units SWH FEL1 30 VSWH FEL1 50 VSWH FEL1 80 V SWH FEL1 100 V
Description Units SWH FEL1 30 VSWH FEL1 50 VSWH FEL1 80 V SWH FEL1 100 V
Factual year
energy
consumption
Constant daily
heating loss
kW•h335,8452,6481,8631,5
kW•h /
day
0,981,231,331,75
IMPORTANT!
Technical characteristics of the water heater you
purchased as of the date of manufacture correspond to
data, specified in the table. Technical characteristics and
scope of delivery can be revised without any prior notice.
Dimensions
Weightkg15,718,823,427,8
4
www.timberk.com • electrical storage water heater
Fig. 1
Capacity, lABCDEFGH
30573593280235.9 432.913.5
50858878450235.9 432.913.5
SWH FEL1
80967987500273.2 492.213.5
10011871207650273.2492.213.5
72.3-
72.3-
103.2-
103.2-
5. WATER HEATER DESCRIPTION
FEL1 series
1 – the upper composite protective cover
2 – external decorative case
3 – system of flows (3 overflows)
4 – urethane foam heat insulation layer
5 – internal tank
6 – heating element
7 – power cable
8 – thermostat sensor pipe
9 – protective magnesium anode
10 – inlet nozzle with a splitter
11 – the lower composite protective cover
12 – composite pressure safety valve (make sure to install onto the cold
water supply tube) Pos. A
13 – emergency discharge of surplus water pressure (a small water leakage
is possible from the emergency discharge hole when the water heater is
operating. It is normal)
14 – hot water outlet nozzle
15 – the upper part of the hot water intake tube
14
7
8
9
10
11
12
Fig. 2
13
Выход
Вход
6. DELIVERY SET
1. Water heater – 1 pc.
2. Anchor bolt – 2 pcs.
3. Pressure safety valve – 1 pc.
4. Discharge pipe – 1 pc.
5. Operation manual – 1 pc.
6. Guarantee card – 1 pc.
7. Packing – 1 pc.
7. WATER HEATER INSTALLATION
Location
1. Electric water heater should be mounted on a firm wall. If the wall is not
robust enough to hold the weight equal to the doubled weight of the total
water heater weight, fully filled with water, then it should be mounted on a
special support.
2. The wall, where the electric water heater is to be mounted, must withstand
at least the double weight of the water heater, fully filled with water; there
must be no cracks and other damages on the wall. Otherwise it is necessary
to take measures to strengthen the mounting or mount the water heater on
a special support.
www.timberk.com • electrical storage water heater
5
3. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to
reduce heat losses in pipelines, the location, where a water heater is to be
installed, must be as close to the place, where hot water is used, as possible.
IMPORTANT!
The water heater must be mounted on a vertical wall
only the position, specified in Fig. 2. Mounting of the
appliance in any other position or vertical or tilting will
inevitably result in failure of the water heater, emergency
situation and is considered a non-guarantee case by the
manufacturer.
Water heater mounting methods
Fig.3 shows the way to mount the water heater for one consumption point.
1. Power cord
2. Water outlet
3. Hot water supply adjustment cock*
4. Mixer*
5. Shower header*
6. Cold water supply adjustment cock*
7. Discharge pipe
8. Composite pressure-relief valve
9. Water inlet
10. Magnesium anode – water discharge nozzle
11. Water main shut-off valve
12. Water main
Fig. 4 shows the way to mount the water heater for one consumption point.
1
6
2
3
4
5
water drain
Fig. 3
www.timberk.com • electrical storage water heater
1
9
8
6
7
10
11
Fig. 4
12
11
8
5
3
4
10
2
water drain
7
6
9
1. Power cord
2. Mounted water heater
3. Composite pressure-relief valve
4. Cold water supply valve*
5. Mixer*
6. Shower header*
7. Water main shut-off valve
8. Discharge pipe
9. Water main
10. Bath*
11. T-joint*
12. Magnesium anode – water discharge nozzle
* not included in the delivery set
IMPORTANT!
Please, use accessories, provided by the manufacturer, to install the water heater. Electric water
heater must not be mounted on a wall prior you make
sure that the bracket is installed firmly and securely.
Otherwise the electric water heater may fall down
from the wall, which may cause its damage and
even serious accidents involving bodily injury. When
determining points for bolt holes, it is necessary to
provision some spare space between the lower part
of the water heater and the floor.
1. Electric water heater should be mounted on a firm wall. If the wall is not
robust enough to hold the weight equal to the doubled weight of the overall
water heater weight, fully filled with water, then it should be mounted on a
special support.
Fig. 6
2. After you chose the proper place to install the water heater, determine
points for holes for expansion hook bolts (to be determined in accordance
with the data sheet for the appliance you chose). Drill two holes of the
corresponding depth in the wall using a drill, dimensionally fit for expansion
bolts, enclosed with the water heater, insert bolts, turn the hook upwards,
securely tighten nuts and then hang the electric water heater on these hooks
(see Fig. 6).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
230V/10A, single-phase, three-wired. It is recommended to place the outlet
on the right side above the water heater.
4. If a bathroom is too small, the water heater can be installed elsewhere,
unexposed to direct sunlight and unavailable for moisture. However, to
reduce heat losses in pipelines, the location, where a water heater is to be
installed, must be as close to the place, where hot water is used, as possible.
NOTE:
In places or on the wall, where water may get to, the
power outlet installation height must be not less than
1.8 m.
Fig. 5
(top view)
for FEL1
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.7 MPa.
www.timberk.com • electrical storage water heater
7
NOTE:
The water heater is the appliance, operating in such
a manner that pressure of water in the water heater
corresponds to the pressure of water in water main.
If pressure in the main exceeds 0.7 MPa, then it is
necessary to mount a pressure reducer before the
water heater so that pressure doesn’t exceed 0.7MPa.
2. G1/2 diameter pipes are used to connect the water heater to the water
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing gaskets
on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed arrow
of the water flow direction, so that the water flow direction coincides with
direction of the arrow on the valve’s case.
NOTE:
Do not mount additional accessories, such as a shutoff valve, between the relief valve and the inlet nozzle.
5. Water heater with the mounted valve must be connected to the water
main – install a shut-off valve at the water inlet point. You need to connect
a drain pipe to the opening of the pressure relief of safety valve. Next you
should put a drain pipe to the sewer.
6. Connect the desired number of consumption points to the outlet nozzle,
marked red.
7. Check leak integrity of joints: open the shut-off cock and one of the cock
assemblies. After the tank is filled with water, as evidenced by issue of water
from the cock assembly, shut the cock assembly and check the leak integrity
of all joints.
IMPORTANT!
If water in the installation location contains a large
amount of calcium, manganese or iron salts, then
IT IS NECESSARY to mount a respective filter in
the delivery system to reduce the amount of scale
generated in the tank and on the heating element.
Connection to electric main
IMPORTANT!
Prior to connecting the tank water heater, make sure
that the water heater is properly grounded. Proper
grounding is important to minimize electric shocks
and risk of fire. The power cord is equipped with a plug
with a grounding pin. The appliance must be used
with a properly grounded power outlet. If the outlet,
you are intending to use, is not properly grounded or
grounded by a time-delay fuse or a circuit breaker,
contact a qualified electrician to install a proper outlet.
1. The water heater is designed to be connected to 230V single-phase
electric main. Prior to connecting make sure that parameters of the electric
main in the place of connection correspond to parameters, specified on the
identification plate with technical parameters of the appliance. You should
follow the current electrical safety code when installing the water heater.
2. The power outlet must be properly grounded. The outlet must be
designed for rated current not less than 10A. The power outlet and plug
must always be dry to prevent current leakage. Regularly check if the
power plug is tightly connected to the outlet. Do it in the following order:
insert the power plug into the outlet, switch off the water heater after halfhour operation and unplug the cord, check if the plug is heated by your
hand. If the plug is heated over 50°C, then to prevent damages, accidents
and fire as a result of bad electrical contact, replace the outlet with a new
one. A specialist must do this.
8
www.timberk.com • electrical storage water heater
IMPORTANT!
Wall outlet should be rated on voltage not lower than
10А, electric main cabel with cooper section not
lesser then 3х1,5 mm2 (for cooper).
Electric socket should be no lower, than 10A, power card with copper inner
part, cross-section of copper should be not less, than 3x1,5 mm2.
IMPORTANT!
To provide reliable operation and safe use of the
water heater, prior to the first run check if it is properly
connected to the 220~/50 V AC mains. The water
heater to be connected must be securely linked with
the earth circuit of your electric mains.
8. WATER HEATER CONTROL
Control panel
54
23
4
1
Water heater operation
1. Switching on
1.1 At first, open one of the hot water outlet valves, then open the cold
water supply valve. The electric water heater will start filling with water.
When water flows from the hot tap freely, it means the water heater is fully
filled with water and you can close the hot water outlet valve.
NOTE:
During normal operation the cold water supply valve
must be set “open”.
1.2 Plug the power cord into the outlet, at that an indicator light on control
panel.
2. Water heating temperature setting
2.1. Temperature can be set within the range 35°С-75°С, in increments
of 1°С.
2.2 The water heater automatically maintains water temperature. When
water temperature in the water heater reaches the temperature, set by the
NOTE:
When setting temperature, having reached the
optimal heating position “ ” (+58°С (+/- 2°С), you
will hear a sound signal (for some models).
user, the heating is automatically switched off. When water temperature
in the water heater drops to a certain level, the heating is automatically
switched off.
Fig. 7
1. Thermostat handle
2. Power supply Indicator
3. Heating indicator
4. LED - display
IMPORTANT!
Water may start dripping from the relief valve hole
during heating. It is impossible to avoid water leakage
and you must not prevent it since valve blocking
may cause rupture of the internal tank (in case of
equipment failure).
www.timberk.com • electrical storage water heater
9
9. MAINTENCE
switched off or not switched on. To reset the water heater to the operating
condition, it is necessary to:
- de-energize the water heater, remove the plate of the side / lower cover
for horizontal-type/vertical-type water heater respectively.
- for SWH FEL1 series vertical-type water heaters: unscrew retaining nut of
the thermal switch, fastened on the flange of the heating element, turn the
thermal switch and press the button, located in the center of the thermal
switch, until it clicks; Fig. 9;
- if the button is not pressed and there is no clicking, then you should wait
until the thermal switch cools down to the initial temperature.
Fig. 8
1. Check the power plug and outlet as often as possible. Secure electrical
contact and also proper grounding must be provided. The plug and outlet
must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with
low air temperature (below 0°C), it is necessary to drain water from the
heater .
3. To ensure long reliable water heater operation, it is recommended to
regularly clean the internal tank and remove deposits on the electric heating
element of the water heater, as well as check condition of the magnesium
anode and, if necessary, replace it with a new one.
Fig. 9
IMPORTANT!
The manufacturer provides an extended guarantee
for particular water heater components provided that
timely and proper routine maintenance is performed
by specialists of an authorized service center (see the
guarantee card).
4. Preventive operations must be performed upon strict observance of the
operation manual and safety precautions.
5. The water heater is equipped with a thermal switch, which cuts off power
supply of the heating element upon water overheating or its absence in the
water heater. If the water heater is connected to the mains, but water is
not heated and the indicator doesn’t light up, then the thermal switch was
10
www.timberk.com • electrical storage water heater
IMPORTANT!
If these actions had no positive result or the thermal
switch turns off repeatedly during a short period of
time, then you should de-energize the water heater,
cut off water supply and contact your local Timberk
Authorized Service Center for a consult or repair of the
appliance.
6. To drain water from the internal tank properly, water can be drained
through a composite relief valve (Fig. 8) (unscrew the composite relief valve
drain knob screw and set the drain knob to the upper position, at that hot
water tap must be open, and cold water supply valve must be closed).
7. Bear in mind to check serviceability of the relief valve every 14 days –
inspection method:
- turn the discharge lever to the left up until you feel the change of thread,
then water must start flowing from the valve’s hole. After checking the
water flow, return the lever to its initial position.
8. If necessary, wipe external surfaces of the heater by a damp cloth with
soap.
10. TROUBLESHOOTING
11. WIRING DIAGRAM
Possible malfunctions and troubleshooting methods
Table 2
FailurePossible causesTroubleshooting method
Heating indicator light doesn’t light up,
water is not heated
Water doesn’t flow from the hot water
discharge cock
Water temperature is too highWater temperature control system
Water leakageSeal at the point of pipe connection
Water flows from the appliance’s case Breaking of the internal tank
1. Temperature adjustment device
is broken.
2. Temperature limiter was actuated or
was not switched on.
3. Temperature limiter is broken.Contact a repairer, TIMBERK ser vice
1. Water feed is cut off.1. Wait until water supply is restored.
2. Water pressure is too low.2. Switch on the water heater again,
3. Water supply exhaust valve is
closed.
is damaged.
is broken.
(corrosion)Seal at the point of the
heating element connection is broken.
Contact a repairer, TIMBERK service
center.
Switch on the temperature switch
following instructions on its activation.
(page 15)
center.
when normal water pressure restores.
Contact a repairer, TIMBERK service
center.
Replace the joint seal.
Contact a repairer, TIMBERK service
center.
Temperature
limiter
Fig. 10
Power
Thermostat
Heating
Heating
element
www.timberk.com • electrical storage water heater
11
13. DISPOSAL
The water heater should be disposed upon the end of life. You can obtain
detailed information on water heater disposal from a representative of local
authorities.
Device service life is 10 years.
NOTE:
Technical and any other characteristics of the
appliance can be revised.
Such changes may be introduced without warning and
prior notice to the consumers.
The manufacturer shall not be liable for changes in the
appliance’s wiring diagram that may be implemented
without notice to the consumers.
14. SERIAL NUMBER AND PRODUCTION DATE
Serial number, production month and year are included in ID LINE product
code. Sticker with ID LINE code is pasted on product surface. Month and
two last numbers of year is putted after symbol “-“.
12
www.timberk.com • electrical storage water heater
Loading...
+ 28 hidden pages