We thank you for your happy choice and buying of a electric
dehumidifier TIMBERK. It will serve you for a long time.
Is intended for dehydration of air in domestic premises
1. IMPORTANT INFORMATION
Is intended for dehydration of air in domestic premises
the appliance is designed for air cooling in domestic
premises. The manufacturer reserves the right to
introduce changes in design, configuration and
processing of the article with a view to improve its
properties without any prior notification of customers.
There may be some misprints in text and digital
notations of the present manual. If after reading of
this manual you have any questions concerning work
and operation of the appliance, please, refer to a shop
assistant or to a specialized service center for further
explanations.
The article has a label with all the needed technical
data and other useful information about the appliance.
Use the appliance only for its intended purpose
indicated in this manual.
2
www.timberk.com • Electric drier for changing of air humidity
2. SAFEGUARDS
3. SPECIFICATIONS
1. DON’T CLOSE VENTS! Make sure that vent inlet and outlet are free.
2. Don’t insert foreign objects in air-outlet grille of the drier. It is very
dangerous, since the fan revolves at high speed.
3. Install the appliance only on a horizontal surface to avoid water leakage.
4. Don’t install the appliance in the following locations:
- where it is exposed to direct sunlight;
- near sources of open flame;
- near other working heating appliances;
- where the appliance may be exposed to water splashes or steam.
5. Don’t use the appliance in explosive or corrosive environment. Don’t
keep petrol and other volatile flammable liquids near the drier – it’s very
dangerous!
6. Don’t use the appliance only for drying (reducing of humidity level) of air
in domestic premises.
7. Clean the filter occasionally to ensure efficient work of the appliance.
8. To ensure reliable work of the compressor, don’t incline the appliance.
9. To avoid electric shock, a damaged power cord should be replaced only
in authorized service centers by qualified specialists.
10. Connect the appliance only to 220-230V~50Hz network. If needed,
find out characteristics of your network from power suppliers
Specifications are shown in table below.
Model DH TIM 20 E7 DH TIM 25 E7
Capacity of draining (L/d)2025
Water tank volume (L)33
Rated power consumption (W)440550
Power supply, V/Hz220~/50220~/50
Rated power current (A)2,12,6
3
Air circulation m
Noise level dB(A)48/4548/45
RefrigerantR135AR135A
Electrical protection classI classI class
Degree of protection against moistureIPX0IPX0
Filling of Freon, g105120
Operating temperature range: ° C 5-355-35
Net weight (kg)14,013,5
Gross weight (kg)15,115,0
Net dimensions (mm)330x260x420330x260x420
Packing dimensions (mm)365x285x505365x285x505
/h170/150170/150
www.timberk.com • Electric drier for changing of air humidity
3
4. APPLIANCE DESCRIPTION
Identification of parts
FrontRear
Fig. 1
1. Control panel
2. Handle (both sides)
3. Air outlet grille
4. Water bucket
5. Water level window
Fig. 2
1. Drain hose outlet
2. Caster
3. Power Cord and plug
4. Air intake grille
5. Air filter (behind the grill)
6. Power cord Buckle(Used only
when storing the unit.)
Positioning the unit
A dehumidifier operating in a basement will have little or no effect in
drying an adjacent enclosed storage area, such as a closet, unless here is
adequate circulation of air in and out of the area.
• Do not use outdoors.
• This dehumidifer is intended for indoor residential applications only. This
dehumidifier should not be used for commercial or industrial applications.
• Place the dehumidifier on a smooth, level floor strong enough to support
the unit with a full bucket of water.
• Allow at least 20 cm of air space on all sides of the unit for good air
circulation.
• Place the unit in an area where the temperature will not fall below
O
C(41OF). The coils can become covered with frost at temperatures below
5
O
C(41OF), which may reduce performance.
5
• Place the unit away from the clothes dryer, heater or radiator.
• Use the unit to prevent moisture damage anywhere books or valuables
are stored.
• Use the dehumidifier in a basement to help prevent moisture damage.
• The dehumidifier must be operated in an enclosed area to be most
effective.
• Close all doors, windows and other outside openings to the room.
NOTE:
All the pictures in the manual are for explanation
purposes only.Your unit may be slightly different.The
actual shape shall prevail.The operations and functions
are the same.
4
www.timberk.com • Electric drier for changing of air humidity
Fig. 3
Casters(Install at four points on the bottom of unit)
• Casters can only move laterally.
• Do not force casters to move over carpet, nor move the unit with water
in the bucket. (The unit may tip over and spill water.)
NOTE:
Casters is optional,some models without.
5. DELIVERY SET
Completed set of the appliance:
Appliance (air drier) - 1 piece
Appliance packing - 1 piece
User manual and Guarantee slip -1 piece
6. APPLIANCE CONTROL
When using the unit
• When first using the dehumidifier, operate the unit continuously 24
hours. Make sure the plastic cover on the continuous drain hose outlet
install stightly properly so there are no leaks.
• This unit is designed to operate with a working environment between
O
C/41OF and 35OC/95OF.
5
• If the unit has been switched off and needs to beswitched on again
quickly, allow approximately three minutes for the correct operation to
resume.
• Do not connect the dehumidifier to a multiple socket outlet, which is
also being used for other electrical appliances.
• Select a suitable location, making sure you have easy access to an
electrical outlet.
• Plug the unit into a electrical socket-outlet with earth connection.
• Make sure the Water bucket is correctly fitted otherwise the unit will
not operate properly.
NOTE:
When the water in the bucket reaches to a certain
level,please be careful to move the machine to avoid it
falling down.
NOTE:
The control panel of the unit you purchased may be
slightly different according to the models.
Fig. 4
Indicator lights
When you push the button to change operation modes, the unit will make
a beep sound to indicate that it is changing modes.
1. COMFORT Pad (optional)
Press to activate the comfort dehumidifying operation.
www.timberk.com • Electric drier for changing of air humidity
5
NOTE:
On this operation,the unit can not be set humidity level.
2. Mode Pad
Press to select the desired operation mode from ehumidifying, Dryer,
Continuous dehumidifying and Smart dehumidifying.
3/4. : Down/Up Pads
Humidity Set Control Pads.
The humidity level can be set within a range of 35%RH(Relative
Humidity) to 85%RH(Relative Humidity) in 5% increments.
For drier air, press the « » pad and set to a lower percent value(%).
For damper air, press the « » pad and set a higher percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and Auto stop time from
0.0 to 24.
5. Timer Pad
Press to initiate the Auto start and Auto stop feature, in conjuction with
the and key pads.
6. Turbo Pad
Control the fan speed. Press to select either High or Normal fan speed.
Set the fan control to High for maximum moisture removal. When the
humidity has been reduced and quiet operation is preferred, set the fan
control to Normal.
7. Ion Pad(optional)
Press to activate the ionizer. Anions ar automatically generated by
ionization. The anions deactive the airborne chemical vapors and dust
particles. Press it again to stop the function.
8. Display
Shows the set % humidity level from 35% to 85% or auto start/stop
time (0~24) while setting, then shows the actual ( ± 5% accuracy) room
% humidity level in a range of RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes and Protection Codes:
AS - Humidity sensor error--Unplug the unit and plug it back in. If error
repeats, call for service.
ES - Temperature sensor error-- Unplug the unit and plug it back in. If
error repeats, call for service.
P1 - Unit is defrosting-- Allow the unit time to automatically defrost.
The protection will clear after the unit self defrosts.
P2- Bucket is full or bucket is not in right position-- Empty the bucket
and replace it in the right position.
E3 - Unit malfunction-- Unplug the unit and plug it back in. If error
repeats, call for service.
EC -Refrigerant leakage detection-- With this new technology, the
display area will appear EC when the unit detects refrigerant leakage,
call for service.
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied, or when the bucket is
removed or not replaced in the proper position.
Auto Shut OFF
The dehumidifier huts off when the bucket is full, or when the bucket is
removed or not replaced in the proper position.When the setting humidity
is reached, the unit will be shut off automatically. For some models,the fan
motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in the first 3
minutes. This is to protect the unit. Operation will automatically start after
3 minutes.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will automatically control room
humidity in a comfortable range 45%~55% according to the room
temperature. The humidity setting function will be invalid.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will restart with
6
www.timberk.com • Electric drier for changing of air humidity
the previous function setting automatically when the power resumes.
Setting the Timer
• When the unit is on, first press the Timer button, the Timer Off indicator
light illuminates. It indicates the Auto Stop program is initiated. Press it
again the Time On indecator light illuminates.It indicates the Auto Start is
initiated.
• When the unit is off, first press the Timer button, the TIMER ON indicator
light illuminates. It indicates the Auto Start program is initiated. Press it
again the Time Off indecator light illuminates.It indicates the Auto Stop is
initiated.
• Press or hold the UP or DOWN pad to change the Auto time by 0.5 hour
increments, up to 10 hours, then at 1 hour increments up to 24 hours. The
control will count down the time remaining until start.
• The selected time will register in 5 seconds and the system will
automatically revert back to display the previous humidity setting.
• When the Auto start & Auto stop times are set, within the same program
sequence, TIMER ON OFF indicator lights illuminate identifying both ON
and OFF times are now programmed.
• Turning the unit ON or OFF at any time or adjusting the timer setting to
0.0 will cancel the Auto Start/Stop function.
• When LED display window displays the code of P2, the Auto Start/Stop
function will also be cancelled.
Dryer mode(optional)
The unit can make the MAX dehumidification function when it is under the
Dryer mode. The fan speed is fixed at high fan speed. The humidity level is
automatically controlled according to the actual room humidity.The unit will
quit dryer mode after a maximum 10 hours’ operation.
NOTE:
• The Dryer mode must be operated in a close room,do not
open the door and window.
• To make the best effective dehumidification ,please first
dehydrate the wet clothes.
• Make sure to direct airflow at the wet clothes (See Fig. 5).
• For thick and heavy wet clothes may not get the best
effective dehumidification.
Fig. 5.
CAUTION!
• Do not cover the air outlet of the unit with clothes. It
may cause excessive heat, fire or failure of unit.
• Do not place the wet clothes on the top of the unit
and do not make the water drop into the unit. It may
cause electric shock,creepage or failure of unit.
www.timberk.com • Electric drier for changing of air humidity
7
7. MAINTENANCE
Removing the collected water
There are two ways to remove collected water.
1. Use the bucket
• When the unit is off,if the bucket is full, the Full indicator light will light.
• When the unit is on,if the bucket is full, the compressor and the fan turn
off, and the Full indicator light will light, the digital display shows P2.
• Slowly pull out the bucket. Grip the left and right handles securely, and
carefully pull out straight so water does not spill. Do not put the bucket
on the floor because the bottom of the bucket is uneven. Otherwise the
bucket will fall and cause the water to spill.
• Throw away the water and replace the bucket. The bucket must be in
right place and securely seated for the dehumidifier to operate.
• The machine will re-start when the bucket is restored in its correct position.
2. Continuous draining
Water can be automatically emptied into a floor drain by attaching the unit
with a water hose (not included).
• Cut the cover down from the back drain hose outlet. Attach a drain
hose(ID=13.5mm) and lead it to the floor drain or a suitable drainage
facility(see Fig.7).
• Make sure the hose is secure so there are no leaks.
• Direct the hose toward the drain,making sure that there are no kinks that
will stop the warter flowing.
• Place the end of the hose into the drain and make sure the end of the
hose is level or down to let the water flow smoothly.Do never let it up.
• Select the desired humidity setting and fan speed on the unit for
continuous draining to start.
Fig. 7
Fig. 6
NOTE:
• When you remove the bucket, do not touch any parts
inside of the unit. Doing so may damage the product.
• Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
push it in securely may cause the unit not to operate.
• When you remove the bucket,if there is some water in
the unit you must dry it .
8
www.timberk.com • Electric drier for changing of air humidity
NOTE:
When the continuous drain feature is not being used,
remove the drain hose from the outlet and attach the
rubber plug back to the drain outlet.
Care and cleaning of the dehumidifier
Turn the dehumidifier off and remove the plug from the wall outlet before
cleaning.
1. Clean the Grille and Case
• Use water and a mild detergent. Do not use bleach or abrasives.
• Do not splash water directly onto the main unit. Doing so may cause an
electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
• The air intake and outlet grilles get soiled easily, so use a vacuum
attachment or brush to clean.
2. Clean the bucket
Every few weeks, clean the bucket to prevent growth of mold, mildew
and bacteria. Partially fill the bucket with clean water and add a little mild
detergent. Swish it around in the bucket, empty and rinse.
CAUTION!
DO NOT operate the dehumidifier without a filter
because dirt and lint will clog it and reduce performance.
NOTE:
Do not use a dishwasher to clean the bucket. After
clean, the bucket must be in place and securely seated
for the dehumidifier to operate.
3. Clean the air filter
The air filter behind the front grille should be checked and cleaned at least
every 30 days or more often if necessary.
CAUTION!
DO NOT RINSE OR PUT THE FILTER IN AN
AUTOMATIC DISHWASHER.
To remove:
• Grip the tab on the filter and pull it upward, then pull it out as shown in
Fig.8.
• Clean the filter with warm, soapy water. Rinse and let the filter dry before
replacing it. Do not clean the filter in a dishwasher.
To attach:
Insert the air filter into the unit from underside to upside. See Fig.9.
Fig. 9
4. When not using the unit for long time periods
• After turning off the unit, wait one day before emptying the bucket.
• Clean the main unit, bucket and air filter.
• Cover the unit with a plastic bag.
• Store the unit upright in a dry, well-ventilated place.
www.timberk.com • Electric drier for changing of air humidity
9
8. TROUBLESHOOTING
9. TRANSPORTATIOM AND STORAGE
Before calling for service, review the chart below first yourself.
ProblemWhat to check
• Make sure the dehumidifier s plug is pushed completely into
Unit does not start
Dehumidifier does
not dry the air as it
should
The unit makes a
loud noise when
operating
Frost appears on the
coils
Water on floor
ES, AS, P1 or P2
appear in the display
the outlet.
• Check the house fuse/circuit breaker box.
• Dehumidifier has reached its preset level or bucket is full.
• Water bucket is not in the proper position.
• Did not allow enough time to remove the moisture.
• Make sure there are no curtains, blinds or furniture blocking
the front or back of the dehumidifier.
• The humidity selector may not be set low enough.
• Check that all doors, windows and other openings are
securely closed.
• Room temperature is too low, below 5
• There is a kerosene heater or something giving off water
vapor in the room.
• The air filter is clogged.
• The unit is tilted instead of upright as it should be.
• The floor surface is not level.
This is normal. The dehumidifier has Auto defrost feature.
• Hose to connector or hose connection may be loose.
• Intend to use the bucket to collect water, but the back drain
plug is removed.
These are error codes and protection code. See the CONTROL
PADS ON THE DEHUMIDIFIER section.
0
C(41 0F).
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
From -30° to +50°
From 15% to 85%
(without a condensate)
We are exploring new technologies and we constantly improving the
quality of our products. That’s why specifications, design and accessories
are subject to change without any specific notice.
* This product must have storage in dry, well-ventilated space of warehouse at the
temperature not lower than -30°
10.SERVICE LIFE
Service life of the appliance is 10 years provided that the respective
installation and operation rules are observed.
Date of the conditioner manufacture is shown in a serial number of the
device. For more details, please, ask a shop assistant.
11. UTILIZATION RULES
Upon expiration of the service life, the appliance should be utilized in
accordance with norms, regulations and procedures effective in the
place of utilization.
10
www.timberk.com • Electric drier for changing of air humidity
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.