Laguna Nero
SERIES
Instruction manual Руководство по эксплуатации
Электрический |
Electric air |
кондиционер воздуха, |
conditioner, |
сплит-система |
split-system |
|
|
Модели/Models:
Электрический кондиционер воздуха, сплит-система (внутренний блок)
Electrical air conditioner, split-system (indoor unit)
•AC TIM 07H S10B
•AC TIM 09H S10B
•AC TIM 12H S10B
•AC TIM 18H S10B
•AC TIM 21H S10B
•AC TIM 27H S10B
Электрический кондиционер воздуха, сплит-система (наружный блок)
Electrical air conditioner, split-system (outdoor unit)
•AC TIM 07H S10B-01
•AC TIM 09H S10B-01
•AC TIM 12H S10B-01
•AC TIM 18H S10B-01
•AC TIM 21H S10B-01
•AC TIM 27H S10B-01
Руководство по эксплуатации включает в себя гарантийный талон
Outlook of devices, aslo colour scores can be revised without any special advance notices.
Производитель вправе менять внешний вид прибора и цветовую гамму прибора без специального уведомления.
|
|
CONTENTS |
|
|
|
|
|
1. |
Important information........................................................................ |
2 |
|
2. |
Safeguards........................................................................................ |
2 |
|
3. |
Specifications.................................................................................... |
4 |
|
4. |
Appliance description........................................................................ |
6 |
|
5. |
Delivery set........................................................................................ |
6 |
|
6. |
Appliance control.............................................................................. |
6 |
|
7. |
Operating modes.............................................................................. |
8 |
|
8. |
Maintenance..................................................................................... |
9 |
|
9. |
Troubleshooting................................................................................. |
10 |
|
10. |
Transportatiom and storage............................................................ |
10 |
|
11. |
Service life....................................................................................... |
10 |
|
12. |
Utilization rules................................................................................ |
10 |
Dear customer!
We thank you for your happy choice and buying of a domestic air conditioner TIMBERK. It will serve you for a long time.
Is intended for cooling, heating, dehydration of air in domestic premises.
1. IMPORTANT INFORMATION
The appliance is designed for air cooling in domestic premises. The manufacturer reserves the right to introduce changes in design, configuration and processing of the article with a view to improve its properties without any prior notification of customers. There may be some misprints in text and digital notations of the present manual.
If after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations.
The article has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purpose indicated in this manual.
2 |
www.timberk.com • Electric air conditioner |
|
|
2. SAFEGUARDS
1.Don’t try to install the conditioner by yourself. Call for a qualified installation specialist.
2.While using the air conditioner, it is necessary to observe several precautions. Incorrect operation due to ignoring of precautions may result in personal injury of a user and other people, as well as in damaging of their property.
3.The electric appliance should be under observation while operated, especially if there are any children near it.
4.Don’t pass your fingers or foreign objects through an air outlet grille of indoor and outdoor units, since it may result in a trauma caused by a revolving fan.
5.Don’t let children turn the conditioner on by themselves. Children may turn the conditioner on only under the care of adults.
6.Don’t try to repair the conditioner by yourself. Internal units of the conditioner carry a voltage and it is life-threatening! For repair of the appliance refer to an authorized service center.
7.Don’t use the appliance if it is faulty, or if it was dropped or damaged. 8.Don’t open a front panel of the appliance during its work.
9.Don’t dismantle and modify the appliance.
10.Unplug the conditioner immediately, if it emits strange odours or smoke.
11.Don’t splash and pour water and other liquids on the conditioner. 12.Always unplug the conditioner during a lighting storm. 13.Always unplug the conditioner, when it is not used.
14.Before cleaning and maintenance of the conditioner unplug it. Cleaning and maintenance should be performed in accordance with instructions of this manual.
15.To ensure the effective work of the conditioner, operate it in environment described in the present manual.
16. Don’t use dangerous chemicals for cleaning of the appliance and don’t let them on the appliance.
17.When removing an air filter, don’t touch metal parts of the appliance.
18.To avoid overheating and risk of flash fire, as well as damage of internal electric network, don’t change the length of a power cord and don’t connect the appliance via extension cords.
19.To avoid electrical hazards, damaged power cord must be changed only at authorized service centers qualified professionals.
20.To avoid risk of electric shock, do not place the power cord near a heater and flammable or combustible substances.
21.Do not start or stop the unit by connecting or disconnecting electrical power.
22.To avoid electric shock, a damaged power cord should be replaced only in authorized service centers by qualified specialists.
23.To avoid electric shock, don’t place the power cord near heating appliances and flammable or combustible substances.
24.Don’t start and stop the appliance by power-up and down.
www.timberk.com • Electric air conditioner |
3 |
|
|
3. SPECIFICATIONS
Model |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Indoor unit |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Outdoor unit |
AC TIM 07H S10B-01 |
AC TIM 09H S10B-01 |
AC TIM 12H S10B-01 |
AC TIM 18H S10B-01 |
AC TIM 21H S10B-01 |
AC TIM 27H S10B-01 |
|
|
|
|
|
|
|
|
|
Capacity (cooling) |
2,13 |
2,6 |
3,2 |
4,9 |
6,0 |
7,2 |
|
(kW) |
|||||||
|
|
|
|
|
|||
Capacity (heating) |
2,25 |
2,7 |
3,5 |
5,1 |
6,2 |
7,4 |
|
(kW) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Rated power |
760 |
860 |
1060 |
1740 |
2135 |
2240 |
|
consumption (cooling) |
|||||||
(W) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated power |
700 |
780 |
1025 |
1410 |
1800 |
2160 |
|
consumption (heating) |
|||||||
(W) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power supply V/Hz |
220~/50 |
220~/50 |
220~/50 |
220~/50 |
220~/50 |
220~/50 |
|
|
|
|
|
|
|
|
|
Rated power current |
3,3/3,1 |
3,7/3,4 |
4,8/4,9 |
7,9/6,4 |
9,5/8,0 |
10,1/9,7 |
|
(cooling/heating) (A)) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Air circulation (indoor |
450 |
500 |
500 |
800 |
900 |
1050 |
|
unit) m3/h |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Air circulation (outdoor |
1400 |
1400 |
1500 |
1800 |
2300 |
2900 |
|
unit) m3/h |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Noise level (indoor |
31-40 |
31-39 |
32-40 |
37-44 |
42-46 |
42-48 |
|
unit) dB(A) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Noise level (outdoor unit) |
51 |
51 |
54 |
54 |
54 |
56 |
|
dB(A) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Refrigerant |
R410A |
R410A |
R410A |
R410A |
R410A |
R410A |
|
|
|
|
|
|
|
|
|
Energy efficiency |
C/C |
B/B |
B/B |
C/A |
С/B |
A/B |
|
(cooling/heating) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
4 |
www.timberk.com • Electric air conditioner |
|
|
Model |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Indoor unit |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Outdoor unit |
AC TIM 07HS10B-01 |
AC TIM 09H S10B-01 |
AC TIM 12H S10B-01 |
AC TIM 18HS10B-01 |
AC TIM 21H S10B-01 |
AC TIM 27H S10B-01 |
|
|
|
|
|
|
|
|
|
Electrical protection |
I class |
I class |
I class |
I class |
I class |
I class |
|
class |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Degree of protection |
|
|
|
|
|
|
|
against moisture |
IPX0 |
IPX0 |
IPX0 |
IPX0 |
IPX0 |
IPX0 |
|
(indoor unit) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Degree of protection |
|
|
|
|
|
|
|
against moisture |
IP24 |
IP24 |
IP24 |
IP24 |
IP24 |
IP24 |
|
(outdoor unit) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Refrigerant piping, |
|
|
|
|
|
|
|
Liquid side/Gas side, |
1/4+3/8 |
1/4+3/8 |
1/4+3/8 |
1/4+1/2 |
1/4+1/2 |
3/8+5/8 |
|
(inch) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max. refrigerant pipe |
15 |
15 |
15 |
15 |
15 |
15 |
|
length, (m) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Maximum difference |
5 |
5 |
5 |
5 |
5 |
5 |
|
in level, m |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Filling of Freon, (g) |
410 |
590 |
700 |
1200 |
1450 |
1450 |
|
|
|
|
|
|
|
|
|
Operating temperature |
+18 ~ +43 |
+18 ~ +43 |
+18 ~ +43 |
+18 ~ +43 |
+18 ~ +43 |
+18 ~ +43 |
|
range: cooling, ° C |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Operating temperature |
-7 ~ + 24 |
-7 ~ + 24 |
-7 ~ + 24 |
-7 ~ + 24 |
-7 ~ + 24 |
-7 ~ + 24 |
|
range: heating, ° C |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
www.timberk.com • Electric air conditioner |
5 |
|
|
Model |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Indoor unit |
AC TIM 07H S10B |
AC TIM 09H S10B |
AC TIM 12H S10B |
AC TIM 18H S10B |
AC TIM 21H S10B |
AC TIM 27H S10B |
|
|
|
|
|
|
|
|
|
Outdoor unit |
AC TIM 07HS10B-01 |
AC TIM 09H S10B-01 |
AC TIM 12H S10B-01 |
AC TIM 18H S10B-01 |
AC TIM 21H S10B-01 |
AC TIM 27H S10B-01 |
|
|
|
|
|
|
|
|
|
Net weight, indoor |
8,0 |
8,0 |
8,0 |
11,5 |
13,0 |
15,0 |
|
unit (kg) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Net weight, outdoor |
22,5 |
26 |
28,0 |
35,0 |
39,0 |
57,5 |
|
unit (kg) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Gross weight, indoor |
10 |
10 |
10 |
14 |
15,5 |
17,5 |
|
unit (kg) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Gross weight, outdoor |
24,5 |
28 |
30,5 |
38 |
43 |
61 |
|
unit (kg) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Net dimensions, indoor |
745x250x195 |
746х245х196 |
745х250х195 |
900х299х225 |
900х299х225 |
1080х302х220 |
|
unit (mm) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Packing dimensions, |
835x330x278 |
833x330x278 |
835x330x278 |
983х377х300 |
983х377х300 |
1275х392х318 |
|
indoor unit (mm) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Net dimensions, |
670x250x430 |
680х225х482 |
715х235х540 |
812х256х540 |
850х295х605 |
870х310х700 |
|
outdoor unit (mm) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
Packing dimensions, |
810x360x475 |
812x345x535 |
851x335x600 |
920x335x595 |
995x415x690 |
990x410x780 |
|
outdoor unit (mm) |
|||||||
|
|
|
|
|
|
||
|
|
|
|
|
|
|
6 |
www.timberk.com • Electric air conditioner |
|
|
4. APPLIANCE DESCRIPTION
The conditioner consists of indoor and outdoor units connected by pipelines. The conditioner may be controlled from a remote control board or from an indoor unit control panel.
2 |
11 |
10 |
3 |
|
|
|
|
7 |
|
|
8 |
1 |
|
|
|
4 |
9 |
65
1.Conditioner unit for indoor installation.
2.Front panel.
3.Air-intake grille of the indoor unit.
4.Сontrol panel of the indoor unit.
5.Blinds (deflectors) for distribution of treated air.
6.Air outlet of the indoor unit.
7.Copper tube for gas (freon), connection line*.
8.Tube for condensate removal*.
9.Air-outlet grille of the outdoor unit.
10.Conditioner unit for outdoor installation.
11.Air-intake grilles of the outdoor unit.
5. DELIVERY SET
Complete set of air conditioner (split system) includes:
Conditioner unit for indoor installation -1 piece
Conditioner unit for outdoor installation -1 piece
Remote control board -1 piece
Batteries for remote control board - 2 pcs.
User manual -1 piece
Batteries for remote control board - 2 pcs.
User manual -1 piece
Guarantee slip -1 piece
Packing of indoor-installation unit -1 piece
Packing of outdoor-installation unit -1 piece
* not supplied
6. APPLIANCE CONTROL
The conditioner may be controlled from a remote control board or from an indoor unit control panel.
Description of indoor unit control panel
Fig. 2
f the remote control board is lost or cannot be used at the moment, you may use a control button «on/off» located behind the front panel.
For that, open the front panel carefully by pulling it from the left and right.
* Press the control button to select a needed mode: on/off*
www.timberk.com • Electric air conditioner |
7 |
|
|
|
|
|
|
|
|
|
|
а) Power supple indicator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
b) Sleep mode indicator |
|
|
|
|
|
|
|
|
c) Operation indicator |
|
|
|
|
|
|
|
|
d) Temperature indicator |
|
|
|
|
|
|
|
|
e) Timer indicator |
|
|
|
|
|
|
|
|
f) Heating mode indicator*** |
a |
b |
c d e |
f |
g |
|
g) Cooling mode indicator |
* use of particular indicators depends on model and series.
**design of indicator symbols may differ depending on model and series.
***in some series of simultaneous use of indicators cooling and heating (simultaneous flashing glow) can display modes of drainage and ventilation
Description of remote control board
Fig. 3
1.Button «ON/OFF» (Power). Using this button, you may turn the conditioner on or off.
2, 3.Buttons «TEMP» (increase/decrease). Using this button, you may set needed air temperature indoors.
4.Button «FAN». Using this button, you may select rotation speed of the
indoor unit fan: «Auto», «High», «Middle», «Low».
In “Auto” mode the fan speed will change automatically. In dry mode the fan speed will remain unchanged – “Low”.
5.Button «SWING U-D». Using this button, you may regulate position of air-outlet blinds and forward treated air up and down.
6.Button «TIMER». Pressing this button, you may set the time for turning the conditioner on and off (set the time by pressing “TEMP" buttons up and down). If the conditioner is off, you may set the time for automatic turning on in a set time interval. And vice versa, if the conditioner is on, you may set the time for automatic turning off. Before activation of the Timer function you may specify the needed settings.
7.Button «SLEEP» (Night Care). Using this button, you may turn the sleep mode on and off. Use this mode to reduce operation sound when sleeping, etc. Press the SLEEP button, the air flow sound from the indoor unit is decreased. Press the SLEEP button again can release the mode.
8.Button for selection of operating mode – «MODE». Using this button, you may select a needed operating mode: AUTO, COOL, DRY, HEAT, FAN.
9.Button «TURBO». Using this button, you may turn the turbo mode on and off. In this mode the conditioner shows the maximum cooling (in cool mode) or heating (in heat mode) capacity.
10.Button «SWING L-R». Using this button to adjust the direction of air flow. Pressing this button will wiggle horizontal blinds.
11.Button «Ion». Using this button can be switched on and off air ionizer
12.Button «Light». Using this button you may turn on and turn off the backlight
13.Button «Lock». Using using this button (if you press for more than 3 seconds) can be switched on and off key lock.
Indication of the control board display shall correspond to selected modes.
Work with remote control board
Mounting and replacement of batteries: mount two LR03 alkaline batteries, according to polarity indicated on the remote control board.
In order to avoid malfunction of the remote control board do not insert used batteries or batteries of various types.
If the conditioner is not used for a long time, remove batteries from the board or else electrolyte may leak and damage the board.
8 |
www.timberk.com • Electric air conditioner |
|
|
In normal operation of the conditioner average service life of batteries will be about a half-year.
Replace batteries, if command receiving is not confirmed with an audio signal, or if the display does not show a sign of command transfer. When generating commands from the remote control board, point an IR-radiator at a remote-control signal receiver situated on the indoor unit. Hold the remote control board at the distance of no more than 8 m from the indoor unit.
7. OPERATING MODES
AUTO mode (SMART)
The auto mode is turned on and off with the use of the button “MODE” on the remote control board.
1.While working in the AUTO mode, a microprocessor will automatically select COOL, FAN, HEAT or DRY modes based on the difference between actual and preset air temperature indoors.
2.If the AUTO mode does not provide comfort conditions, select the mode manually. In automatic mode, depending on air temperature in the room, the conditioner will select needed temperature parameters of its operation in the following order:
Temperature indoors |
Automatic mode sele ction |
Automatically maintained temperature |
|
|
|
if <20° С |
then HEAT mode shall be turned on |
23° С |
|
|
|
if <20° С - 26° С |
then DRY mode shall be turned on |
18° С |
|
|
|
if >26° С |
then COOL mode shall be turned on |
23° С |
|
|
|
COOL, HEAT and FAN
1.Turn the conditioner on pressing the "ON/OFF" button.
2.Pressing the "MODE" button, select COOL, HEAT or FAN mode manually.
3.Pressing the "TEMP" button (up-down), set the desired air temperature indoors (except for FAN mode).
4.Pressing the "FAN SPEED" button on the remote control board, select the fan rotation speed: AUTO, LOW, MIDDLE, HIGH, and the conditioner will start working in accordance with the selected setting.
5.To turn the conditioner off, press the "ON/OFF" button once again. In the FAN mode air temperature indoors is not set.
DRY
Turn the conditioner on pressing the "ON/OFF" button. Pressing the "MODE" button, select the DRY mode. The conditioner will start working in the set mode. To turn the conditioner off, press the "ON/OFF" button once again. TURBO mode
When pressing the «TURBO» button on the remote control board, the conditioner will start working in turbo mode – for maximum cooling (in cool mode) or for maximum heating (in heat mode).
TIMER mode
Procedure of timing:
– If the conditioner is off, then press the “TIMER” button to activate the automatic turning on. Pressing this button once again, set the time for turning the conditioner on in the set time interval. To cancel the timer mode, press the “TIMER” button once again.
–If the conditioner is working, then press the “TIMER” button to activate the automatic turning off. Pressing this button once again, set the time for turning the conditioner off in the set time interval. To cancel the timer mode, press the “TIMER” button once again.
SLEEP mode
Button «SLEEP» (Night Care). Using this button, you may turn the sleep mode on and off. Use this mode to reduce operation sound when sleeping, etc.
Press the SLEEP button, the air flow sound from the indoor unit is decreased.
Press the SLEEP button again can release the mode.
Regulation of treated air flow direction
Regulating the position of deflectors (blinds), set the direction of treated air flow ensuring uniform distribution of temperature and the most comfort conditions in the room. To change the position of deflectors, use the «SWING» button.
www.timberk.com • Electric air conditioner |
9 |
|
|
8.MAINTENANCE
•Before cleaning unplug the conditioner.
•Cleaning of the indoor unit and remote control board:
•Indoor unit and remote control board should be cleaned with a dry soft cloth.
•If the indoor unit is too unclean, moisten the cloth with cold water.
•It is prohibited to clean the remote control board with moist cloth.
•In order to avoid the damage of paint or details of the conditioner, do not clean it with brushes and do not leave them on the surface of indoor unit.
•In order to avoid the damage of surface or deformation of the conditioner details, do not clean it with petrol, solvents, cleaning powders or other chemically active substances.
•Before a sustained interruption in the conditioner work:
•Turn the conditioner on for several hours in the FAN mode. It will allow you to dry its inner cavities
•Unplug the conditioner. Remove the batteries from the remote control board. Checks before starting:
•Make sure that an air filter is installed.
•Make sure that air inlet and outlet grilles of the outdoor unit are not blocked by foreign objects.
•Cleaning of air filter
•Air filter cleans the air entering the conditioner from dust and foreign particles. If the filter is contaminated, the conditioner capacity decreases sharply.
•If the conditioner is operated permanently, the filter should be cleaned once per two weeks.
•If the conditioner is installed in a room with dusty atmosphere, then the air filter should be cleaned more often.
•To remove the filter, open the indoor unit panel.
•Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean water. If the filter is contaminated heavily, clean it with a soft brush and wash in diluted washing solution, then dry it in a cool place.
•While cleaning the filter with the vacuum cleaner, hold it with contaminated surface up. While washing the filter in water, hold it with contaminated surface down.
•Do not dry the filter in the sun or near a fire.
•Set the air filter to initial position and close the panel.
9. TROUBLESHOOTING
Failures and their possible reasons:
Failure |
Possible reason |
Actions |
|
|
|
|
|
|
Interruptions in power supply |
Wait for restoration of power |
|
|
supply |
||
|
|
||
|
|
|
|
The conditioner does |
Batteries in the remote control |
Replace the batteries |
|
board are low |
|||
not work |
|
||
|
|
||
|
Time of tuming on is set by |
Wait till the conditooner turns |
|
|
on by the timer or cancel the |
||
|
the timer |
||
|
timer setting |
||
|
|
||
|
|
|
|
|
The set air temperature is too |
Set the air temperature |
|
|
high or too low |
correctly |
|
|
|
|
|
Insufficient cooling or |
The air filter is clogged with dust |
Clean the air filter |
|
heating capacity |
|
|
|
Foreign objects block the air intel |
|
||
|
|
||
|
and retum air grillages of the |
Remove foreign objects |
|
|
outdoor unit |
|
|
|
|
|
|
The conditioner works, |
A three-minute delay of |
Wait a little |
|
compressor tuming on |
|||
|
|||
but does not cool or |
|
|
|
The air temperature is set |
|
||
heat the room |
Set the temperature correctly |
||
|
incorrectly |
||
|
|
||
|
|
|
10 |
www.timberk.com • Electric air conditioner |
|
|
10. TRANSPORTATIOM AND STORAGE
Temperature |
|
|
|
From -30° to +50° |
|
requirements* |
|
Transportation and |
|
|
|
|
|
storage |
|
|
|
Humidity |
From 15% to 85% |
||||
|
|
|
|||
requirements* |
|
|
|
(without a condensate) |
|
|
|
|
|
|
We are exploring new technologies and we constantly improving the quality of our products. That’s why specifications, design and accessories are subject to change without any specific notice.
* This product must have storage in dry, well-ventilated space of warehouse at the temperature not lower than -30°
11.SERVICE LIFE
Service life of the appliance is 10 years provided that the respective installation and operation rules are observed.
Date of the conditioner manufacture is shown in a serial number of the device. For more details, please, ask a shop assistant.
12. UTILIZATION RULES
Upon expiration of the service life, the appliance should be utilized in accordance with norms, regulations and procedures effective in the place of utilization.
www.timberk.com • Electric air conditioner |
11 |
|
|