![](/html/fa/fabb/fabb279d05552668348ff2b2f74ff2479fb8cbdf8bd5e86c5e616b78f95c88e2/bg1.png)
P/N 92235201 • Rev A• ECN 10-092 • 5/20/2010
Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may be returned prepaid.
Model 506F-02-01-04
Fiber Interface Device
Installation Note
Description
Installation
1. The TII 506F-02-01-04 Fiber Optic Interface
Device is a compact fiber optic connectivity
and fiber slack storage enclosure.
2. The large split grommets located at the bottom
of the base allow Telco drop lines and
customer fiber cables to enter and exit the
device.
3. The TII 506F-02-01-04 is supplied with SC
adapters to allow up to six fiber optic
connections.
4. The TII 506F-02-01-04 allows for sufficient
drop/fiber cable slack storage in the base
enclosure.
Features
Figure 1
1. Mount the 506F Device so as to minimize the
possibility of dirt or moisture getting into the
enclosure.
2. 506F Devices mounted side-by-side or end-toend should be placed so covers can easily be
opened.
3. Mount the 506F Device vertically on a flat
surface using appropriate hardware (the
length of the mounting screws should allow for
1/8” of length within the enclosure).
4. The internal mounting holes are covered with
a thin film of plastic, which are easily punched
out, to maintain the environmental integrity of
the enclosure (See Figure 2).
5. In addition to the internal mounting holes
mentioned in step 4, there are external
mounting ears which are provided for exterior
mounting. Mount as previously stated using
the appropriate mounting hardware and
methods (See Figure 2).
6. You are now ready to place the drop/fiber
cable slack into the enclosure and prepare for
wiring.
![](/html/fa/fabb/fabb279d05552668348ff2b2f74ff2479fb8cbdf8bd5e86c5e616b78f95c88e2/bg2.png)
Customer Out
Fiber Cable with
SC Connector
Strain Relief
Pad with
Tie-Wrap
Fiber Cable with
six Connector
Pigtail
Figure 2
Wiring
1. Punch a hole through the left grommet and
guide the Fiber Drop Cable through the entry
grommet.
2. Insert the SC connector from the pre-wired
fiber cable into the left side of the provided SC
Adapter.
3. Insert the SC Connector from the Customer
Out Fiber Cable to the right side of the SC
Adapter.
4. Punch a hole through the right grommet and
guide the Customer Fiber Cables through the
Customer Exit Grommet
5. Wrap the excess Fiber Cable slack in the
clockwise direction and place it into the base
enclosure and under the slack retention
fingers.
6. Use a tie-wrap to hold any spliced connections
and cables to the strain relief pads.
7. Close and secure the cover. Tighten the
security hex screw until it is snug. Be sure not
to over tighten the screw.
Figure 3