TIF9020A Electronic Scale
NOTE: False readings may occur if the scale is used in environments having high
electrical noise. False readings may also occur if the cylinder touches the case or
controls, or if anything touches the platform, especially the cord to the control box.
SETUP
1. Place the unit on a firm and level surface.
2. Remove the control box from the case in order
to provide clearance.
3. Switch unit on by pushing the ON/OFF button.
4. Select the desired unit of measure by pressing
and releasing the UNITS button. Three scales
are available:
lbs./oz. (0 lbs. 0.0 oz.)
decimal pounds (0.000 lbs.)
kilograms (0.000 kg)
OPERATION
1. Carefully place refrigerant cylinder in center of
the platform.
2. Connect refrigerant cylinder to a charging manifold via utility hose if charging refrigerant, or to
a recovery machine if recovering refrigerant.
3.
Open refrigerant tank valve. Purge air from hoses.
4. Press ZERO button; display changes to zero.
5. Open manifold valve(s), or turn on recovery
unit. Refrigerant begins to flow, and display
indicates the weight being removed (if charging) or added (if recovering). A minus sign (-)
appears if weight is being removed.
6. Monitor the display; when desired charge or
maximum allowable fill is reached, close the
cylinder valve and manifold valves, and/or
switch off the recovery unit.
7. When operation is complete, turn unit off by
pushing the ON/OFF button. Close cylinder
valve, disconnect hose(s), and store the unit.
LOW RESOLUTION MODE
In normal operating mode, the high resolution of the
scale may lead to noticeable fluctuations in the reading caused by weight shifts or wind. To improve this
situation, a low resolution mode may be activated.
1. With scale switched on, with any unit or weight
displayed, press and hold the UNITS button.
2. The enunciators (units of measure) will begin to
flash.
3. Release the button and continue normal operation. Resolution is now reduced by a factor of 5
(1.0 oz./.050 lbs./20 g) and will provide stable
readings under extreme conditions.
4. To return to the normal resolution mode,
depress and hold the UNITS button until the
enunciators stop flashing.
WEIGHT MEASUREMENTS
The unit may be used strictly as a weight scale.
1. Follow steps 1 through 4 in Setup.
2. Press the ZERO button. Display changes to zero.
3. Carefully place the object (e.g., cylinder) that is to
be weighed directly in the center of the platform.
4. Gross weight will be displayed.
5. When weighing has been completed, turn unit off.
This feature is especially useful when recovering. To
calculate the amount of refrigerant in a tank, subtract
the "Tare" weight (marked on cylinder) from the displayed amount to find the quantity of refrigerant in
the cylinder.
OVER-RANGE INDICATION
If the gross weight applied to the platform exceeds
the specified range, the unit will display a single 1 at
the left of the display.
BATTERY INSTALLATION
The BATTERY enunciator will appear when the battery
needs replacing. A display of “---” indicates battery
voltage insufficient for operation. Replace battery in
order to resume operation.
1. Remove battery from control box by removing the
battery cover located on the back of the box.
2. Disconnect the battery from the battery clip.
3. Attach a new 9V alkaline battery to the clip.
4. Install new battery and cover.
Designed and engineered in the USA.
Manufactured in China.
DISPLAY INDICATORS
Cylinder
Platform
SPECIFICATIONS
Range: 0 lbs. 0.0 oz. to 199 lbs. 15.8 oz.
0.000 lbs. to 199.990 lbs.
0.000 kg to 100.000 kg
Resolution:
Normal: 0.2 oz. / 0.010 lbs. / 4 g
Low: 1.0 oz. / 0.050 lbs. / 20 g
Accuracy: ± 0.5% of reading ± 1 digit
Power Supply: One 9V alkaline battery
Battery Life: 30 hrs. (approx.)
Operating
°
Temperature: 32
(0°C to 49°C)
Weight: 6.15 lbs. (2.79 kg)
Dimensions: 15.25 x 10.5 x 2.5"
(38.7 x 26.7 x 6.35 cm)
F to 120°F
Features of the Scale
LCD Readout
Expansion
Port
Keypad
Control
Box
Warranty and Repair Policy
This instrument has been designed to
provide unlimited service. Should it
become inoperative after the user has
performed recommended maintenance, a
no-charge repair or replacement will be
made to the original purchaser. This applies
to all repairable units that have not been
damaged or tampered with. The claim must
be made within TWO years of date of
purchase.
An additional 90-day warranty period will
cover the repaired or replaced unit. If you
have questions or need technical
assistance, call toll-free to speak with a
Customer Service Representative:
(800) 327-5060.
655 Eisenhower Drive
Owatonna, MN 55060
Phone: (800) 327-5060
Fax: (866) 287-7222
www.tif.com
552154 Rev B