Airfield Lighting Safegate Group
Section Description Page No.
1. INTRODUCTION ........................................................................................................... 3
SAFETY INSTRUCTIONS ................................................................................ 3
1.1.1. Product Safety ............................................................................................ 3
1.1.2. Electrical Maintenance .............................................................................. 3
1.1.3. Mechanical Maintenance ........................................................................... 4
DESCRIPTION OF THE FITTING .................................................................... 4
DELIVERY OF THE FITTING ........................................................................... 4
2. INSTALLATION ............................................................................................................. 5
FIXATING AND ALIGNING THE FITTING ....................................................... 6
1.2.1. Adaptation of the Fixation Stirrup ............................................................ 6
1.2.2. Adjustment of the Elevation Angle .......................................................... 7
ELECTRICAL CABLING ................................................................................... 8
OPENING/ CLOSING THE FITTING .............................................................. 10
MOUNTING THE LAMP IN THE FITTING ..................................................... 11
INSTALLING THE LOUVER ON THE FITTING (OPTION) ............................ 11
3. MAINTENANCE .......................................................................................................... 12
BASIC MAINTENANCE PROGRAMME ......................................................... 12
WORKSHOP MAINTENANCE ....................................................................... 12
2.3.1. Opening/ Closing the Fitting ................................................................... 13
2.3.2. Replacing the Lamp ................................................................................. 14
2.3.3. Replacing the Louver .............................................................................. 14
2.3.4. Replacing the Front Glass ...................................................................... 15
4. SUPPORT .................................................................................................................... 16
SAFEGATE GROUP WEBSITE ..................................................................... 16
RE-CYCLING .................................................................................................. 16
2.4.1. Local Authority Re-cycling ..................................................................... 16
2.4.2. Safegate Group Re-cycling ..................................................................... 16
SPARE PARTS ............................................................................................... 16
Manual Date: March 2014
Ref: PRT3 Version: 1.0
MANUAL
HELIPORT FLOOD LIGHT
(PRT3)
CONTENTS
Page 1 of 18
![](/html/5f/5f05/5f05e92b39c0e90cc81fa18c261dae67b5c9f95f97b6ab269736dba18660e7f9/bg4.png)
Airfield Lighting Safegate Group
Federal Aviation Administration
International Civil Aviation Organization
International Electrotechnical Committee
North Atlantic Treaty Organization
Service Technique de l'Aviation Civile (France)
Standardization Agreement (NATO)
Manual Date: March 2014
Ref: PRT3 Version: 1.0
Documentation
This document includes Airfield Lighting information with a focus on safety, installation
and maintenance procedures.
Note: It is very important to read this document before any work is started.
Original documentation is created in English (U.K.).
Images and texts used in this document are reference examples only and may not
exactly depict a customer product.
For more information, see www.safegate.com.
Copyright
© Copyright 2011 by Safegate Group. All rights reserved. This item and the
information contained herein are the property of Safegate Group. No part of this
document may be reproduced, transmitted, transcribed, stored in a retrieval system,
or translated into any language or computer language in any form or by any means
otherwise, without the expressed written permission of Safegate Group,
Djurhagegatan 19, SE-213 76 Malmö, Sweden.
History
Version Date Description
1.0 March 2014 First Release
Note: This page is to be updated with every authorised change to the document.
Abbreviations and Terms
This document may include abbreviations and terms.
Page 2 of 18
![](/html/5f/5f05/5f05e92b39c0e90cc81fa18c261dae67b5c9f95f97b6ab269736dba18660e7f9/bg5.png)
Airfield Lighting Safegate Group
WARNING! PRIOR TO THE COMMENCEMENT OF WORK ALL ELECTRICAL
SERVICES MUST BE ISOLATED FROM THE SUPPLY AND CONNECTED TO
EARTH. FULL DETAILS OF THE WORK INVOLVED MUST BE GIVEN TO THE
AUTHORISED PERSON RESPONSIBLE FOR THE ELECTRICAL ENGINEERING
SERVICES AT THE AIRPORT WITH REGARD TO THE DURATION OF THE WORK
AND SO ON. IT IS RECOMMENDED THAT PRIOR TO STARTING ANY CUTTING
WORK, THE NATURE AND LOCATION OF SERVICES SUCH AS CABLE DUCTS
Manual Date: March 2014
Ref: PRT3 Version: 1.0
1. INTRODUCTION
In this section you can find a general description and safety instructions related to the
installation and usage of the fitting.
PRT3 is a flood light that allows lighting of Heliport Touchdown and Lift Off area
(T.L.O.F).
The fitting has many advantages and special features:
Uses the standard R7s 500w linear halogen lamp.
Small size and weight.
Sturdy design.
High efficiency.
Easy access to all components.
Easy installation: mechanical installation and electrical connections are easy to
carry out.
The adjustable light beam is based on a fixation system (Fixation Stirrup and
fixation Holes).
Easy maintenance; replacement of a defective lamp is easy.
Can be equipped of an optional PRT G3 Louver.
SAFETY INSTRUCTIONS 1.1
Make sure you read this section and are familiar with safety precautions before any
work is started.
1.1.1. Product Safety
Airfield lighting fixtures in a constant current circuits are connected in a circuit via
isolating transformers with currents between 2.0 – 6.6A in the primary circuits.. The
primary voltages, depending on the circuitry, are usually several kilovolts and
therefore lethal. Although the open circuit voltages of the isolating transformers are
much lower, the peak voltage while opening the secondary circuit under current is
also hazardous. So it is vitally important to follow all the safety regulations with
adequate circumspection.
In the design of this equipment all the practical safety aspects have been taken into
account. It is also important to strictly follow existing international or national
regulations, the instructions established by civil aviation authority or airport operator
and the following instructions.
1.1.2. Electrical Maintenance
Valid safety regulations must always be followed. Never carry out any maintenance or
maintenance measures before the current is confirmed as safely disconnected. Use
extreme caution when disconnecting or connecting high voltage primary connectors.
Page 3 of 18
![](/html/5f/5f05/5f05e92b39c0e90cc81fa18c261dae67b5c9f95f97b6ab269736dba18660e7f9/bg6.png)
Airfield Lighting Safegate Group
AND THE LIKE SHOULD BE IDENTIFIED. ANY INSTALLATION OR MAINTENANCE
WORK SHOULD ONLY BE CARRIED OUT BY TRAINED AND EXPERIENCED
PERSONNEL. ALSO, WHEN WORKING ON CIRCUITS USING AIRFIELD SMART
POWER SYSTEM (ASP) THE SCM MUST BE TUNED OFF.
Manual Date: March 2014
Ref: PRT3 Version: 1.0
1.1.3. Mechanical Maintenance
When maintaining mechanical components, it is important to follow the instructions for
electrical maintenance.
DESCRIPTION OF THE FITTING 1.2
PRT3 is a flood light that allows lighting of Heliport Touchdown and Lift Off area
(T.L.O.F) as recommend by ICAO in the paragraph 5.3.8 of the Volume II of the
Annex 14.
DELIVERY OF THE FITTING
1.1
Each light fitting is composed of three subassemblies:
1. The PRT3 fitting without lamp and louver.
2. The lamp E27 lamp.
3. The louver (Option).
Each unit is individually packed in a durable cardboard box, labelled with its reference
name and code.
For more information, see www.safegate.com.