READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
*
Note: For operation at elevations above 2000ft., appliance rating shall be reduced at the rate of 4% for each 1000 ft. above sea level.
Top Burner
Simmer
burner
Griddle Burner
Oven Burner
Broil Burner
Bypass Jet
BTU
18000B
TU
15000B
TU
12000B
TU
9000BTU
6000BTU 15000BTU
22000BT
U
14000BT
U
16500B
TU
13000BT
U
Orifice Size
1.22mm/
1.24mm
1.07mm
1.0mm
0.8mm
0.72mm
0.34mm/
0.38mm
1.16mm/1.22mm
1.32mm
1.10mm
1.18m m
1.05mm
HRG3078U
NA 1 2 1 NA 1 NA
1
NA
NA 1 5
HRG3080U
1 1 2
NA
NA 1 NA
1
NA
NA 1 5
HRG3031U
NA 2 2
NA
NA 2 NA
1
NA 1 NA
6
HRG3026U
2 2 NA
NA
NA 2 NA
1
NA 1 NA
6
HRG3609U
NA 2 2
NA
NA 2 1
1
NA 1 NA
6
HRG3617U
2 2 NA
NA
NA 2 1
1
NA 1 NA
6
HRG3603U
NA 2 2 2 NA 2 NA
1
NA 1 NA
8
HRG3618U
1 2 3
NA
NA 2 NA
1
NA 1 NA
8
HRG4804U
NA 3 3
NA
NA 3 1
1 1 1
NA
9
HRG4808U
3 3 NA
NA
NA 3 1
1 1 1
NA
9
Instructions for Converting Range to Operate on Liquefied Petroleum Gas
This conversion kit must be installed by a qualified service technician in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. Failure to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with this kit.
Before proceeding with the conversion, shut off the gas supply before disconnecting electrical power to the range. Be sure power supplies are off before installing the conversion kit. Failure to do so could cause serious bodily injury.
Instructions for Converting Range to Operate on Liquefied Petroleum Gas
IMPORTANT: After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas.
The factory orifices are marked with the following:
Top Burners 1.88mm 18000BTU Top Burners 1.65mm 15000BTU
Top Burners 1.5mm 12000BTU
Top Burners 1.35mm 9000BTU
Top Burners 1.10mm 6000BTU
Oven Burner 2.26mm 22000BTU
Oven Burner 1.70mm 14000BTU
Oven Broiler 1.85mm 16500BTU
Oven Broiler(HRG3080U) 1.63mm 13000BTU
Griddle 1.70mm 15000BTU
Main Burner Bypass Jet 0.88mm 18000 BTU Single Burner Orifice
1.85mm/1.88mm Griddle Burner Orifice 1.94mm/1.70mm
Simmer Bypass Jet 0.46/0.42mm
Tools Required for L.P. Conversion:
10mm,14mm,17mm Open End Wrench 1/8” Wide Flat Blade Screwdriver Philips Screwdriver 7mm Nut Driver (for dual burner main orifice) 6mm Nut Driver (for dual burner simmer orifice) Adjustable wrench
Instructions for Converting Range to Operate on Liquefied Petroleum Gas
**IMPORTANT**
15000 BTU Dual Burner Main Burner Orifice 1.07mm Simmer Orifice for LP 0.38mm/0.34mm
18000 BTU Single Burner Burner Orifice for LP 1.24mm/1.22mm
12000 BTU Single Burner Burner Orifice for LP 1.00m
Infrared Broiler Orifice for LP 1.18mm Griddle Burner Orifice for LP 1.22mm/1.16mm U-Shape Burner Orifice for LP 1.32mm 18” Oven Burner Orifice for LP 1.10mm HRG3080U Broiler Orifice for LP 1.05mm
2.Convert Top Burner for LP/ Propane Gas
Save the natural gas orifices removed from the appliance for possible future conversions to natural gas.
You should accord to the following process to covert to Nature gas. Take extra care when handling steel parts.
a. Remove top grates, burner caps and inner burner rings.
b. Lift off outer burner heads and burner bases. c. Remove the factory installed natural gas orifices from the center of the orifice holders using a 7mm nut driver (See Fig. 2c) Remember to keep the original natural gas orifices for future conversions back to natural gas. Refer to page 1 under “IMPORTANT” to identify their markings. Replace the main orifice in each orifice holder with orifice size 1.07mm. Replace the 18000BTU burner orifice in each with orifice size 1.22mm. Replace the 12000BTU burner orifice in each with orifice size 1.0mm. Replace the 9000BTU burner orifice in each with orifice size 0.8mm. Tighten each orifice until snug. Use caution not to over tighten. d. Use a 6mm nut driver, replace the simmer
orifice in each orifice holder with the orifice size 0.46mm.
Replace the outer burner heads back to the main burner bases. Replace the inner burner rings, burner caps and grates.
3 of 7
Instructions for Converting Range to Operate on Liquefied Petroleum Gas
.
1. Convert the Pressure Regulator
For 30 inch with 16,500BTU Broiler and all 36-inch gas range, please follow the below steps: Pull the range away from the cabinet wall. The gas regulator is located at the bottom right corner of the range. a. Electrical shock hazard can occur and result in injury or death. Disconnect electrical power to the range before servicing. Do not remove regulator or allow it to turn during servicing. b. Unscrew the cap from the regulator. Do not remove the spring from the regulator. c. Unscrew the plastic insert from the cap and turn it over so the longer stem is facing the cap (See Fig.1c-1). Replace insert on the cap. Replace the cap on the regulator. For 30 inch with 13,000BTU Broiler and all 48-inch gas range, follow the below steps According to the steps from 1a to 1g, remove the 30" oven door, the cooking grid and the burner cover. Unscrew the right baffle.
Position for LP
Position for NG
2a
2c
2b
2d
Loading...