Thor Broadcast H-4HD-EMS, H-4HD-EMH, H-4HD-EMHS User Manual

H-4HD-EMH
H-4HD-EMS
H-4HD-EMHS
4 Channel SDI & HDMI
For ASI and IPTV
User Manual 2017
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
A Note from Thor Broadcast about this
Manual
Intended Audience
This user manual has been written to help people who have to use, integrate and to install the product. Some chapters require some prerequisite knowledge in electronics and especially in broadcast technologies and standards.
Disclaimer
No part of this document may be reproduced in any form without the written permission of Thor Broadcast. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Thor shall have no liability for any error or damage of any kind resulting from the use of this document.
Copy Warning
This document includes some confidential information. Its usage is limited to the owners of the product that it is relevant to. It cannot be copied, modified, or translated in another language without prior written authorization from Thor Broadcast.
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
Table of Contents
CHAPTER 1 INTRODUCTION .................................................................................................................... 4
1.1 PRODUCT OVERVIEW .............................................................................................................................. 4
1.2 KEY FEATURES ........................................................................................................................................ 4
1.3 SPECIFICATIONS ...................................................................................................................................... 5
1.4 PRINCIPLE CHART ................................................................................................................................... 6
1.5 APPEARANCE AND DESCRIPTION ............................................................................................................. 6
CHAPTER 2 INSTALLATION GUIDE ........................................................................................................... 8
2.1 GENERAL PRECAUTIONS ......................................................................................................................... 8
2.2 POWER PRECAUTIONS ............................................................................................................................. 8
2.3 DEVICES INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING .................................................... 8
2.4 ENVIRONMENT REQUIREMENT ................................................................................................................ 9
2.5 GROUNDING REQUIREMENT .................................................................................................................. 10
CHAPTER 3 OPERATION ........................................................................................................................ 11
3.1 LCD MENU CLASS TREE ...................................................................................................................... 11
3.2 INITIAL STATUS ..................................................................................................................................... 12
3.3 GENERAL SETTINGS FOR MAIN MENU .................................................................................................. 12
CHAPTER 4 WEB NMS OPERATION ....................................................................................................... 20
4.1 LOGIN .................................................................................................................................................... 20
4.2 OPERATION ........................................................................................................................................... 21
CHAPTER 5 TROUBLESHOOTING ........................................................................................................... 32
CHAPTER 6 PACKING LIST ..................................................................................................................... 33
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
Chapter 1 Introduction
1.1 Product Overview
The Thor Broadcast series SDI and HDMI Pro-DVB 4 channel input encoders are designed for modern state of the art broadcasts for ASI and IP solutions. Managed through any modern web browser, each encoder can be independently adjusted for bitrate, codecs, and video image qualities. Encoding support for the MPEG-2, or H.264, codec along with Dolby AC/3 audio ensure that the programs generated by this encoder can be used around the world on a global scale. All four program streams are multiplexed into an ASI MPTS output on mirrored BNC terminals. The 4 encoded HDMI (HD-SDI) programs will output through ASI and IP ports in MPTS or SPTS. This powerful design allows you to distribute up to 1080p program streams in crystal clear High Definition. This design is topped off with a dual power supply to ensure that your Thor Broadcast encoder has the redundancy needed for any application.
1.2 Key Features
Dual power supply MPEG2 HD/SD & MPEG4 AVC/H.264 HD/SD video encoding MPEG1 Audio Layer 2, LC-AAC, HE-AAC and AC3 audio encoding 4*HDMI or 4*SDI inputs (model dependent) Supports CC(close caption) only for SDI interface EIA 708 VBR/CBR rate control mode Low Latency, best in class of any modern encoder PSI/SI editing and inserting IP null packet filter ASI output, IP (MPTS & 4 SPTS) output over UDP, RTP LCD display, Remote control and firmware Web-based NMS management; Updates via web
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
1.3 Specifications
Encoding Section
Video
Encoding
MPEG2 & MPEG4 AVC/H.264
Input
HDMI*4/SDI*4
Resolution
1920*1080_60P, 1920*1080_50P, (-for MPEG4 AVC/H.264 only) 1920*1080_60i, 1920*1080_50i, 1280*720_60p, 1280*720_50P 720*480_60i, 720*576_50i
Bit Rate
0.5~19.5Mbps for H.264 encoding 1~19.5Mbps for MPEG-2 encoding
Rate Control Mode
CBR/VBR
Audio
encoding
MPEG1 Layer II, MPEG2-AAC, MPEG4-AAC, Dolby Digital AC3
Sample rate
48KHz
Bit rate
64kbps, 96kbps,128kbps, 192kbps, 256kbps, 320kbps
System
Local interface
LCD + control buttons
Remote management
Web NMS
Low Latency Mode
Normal, mode 1, mode 2
output
2*ASI out (BNC type); IP (1 MPTS & 4 SPTS) over UDP, RTP (RJ45, 100M)
NMS interface
RJ45, 100M
Language
English
General
Power supply
AC 100V~240V
Power Consumption
45W
Dimensions
482*400*44mm
Weight
4.5 kgs
Operation temperature
0~45
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
1.4 Principle Chart
ASI Output
MPEG-2 or H.264 HD/SD
Encoding
HDMI/SDI
HDMI/SDI
MPEG-2 or H.264 HD/SD
Encoding
MPEG-2 or H.264 HD/SD
Encoding
MPEG-2 or H.264 HD/SD
Encoding
IP Output
HDMI/SDI
HDMI/SDI
1.5 Appearance and Description
Front Panel Illustration
LCD window Power supply indicators Power Alarm Switch: When only one power supply is connected or one of the power
supplies fails, the device will give alarm sound, and then press the alarm switch to turn off the alarm sound.
NMS port for the connection between the device and PC DATA port for IP signal out Indicators for whole unit power supply, working alarm and input signal lock status Control Buttons Handles
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
Rear Panel -- H-4HD-EMH
HDMI Input Module 1: Program input port 1&2 HDMI Input Module 2: Program input port 3&4 ASI output ports Power Supply Slot Power Switch Grounding
Rear Panel -- H-4HD-EMS
SDI Input Module 1: Program input port 1&2 SDI Input Module 2: Program input port 3&4 ASI output ports Power Supply Slot Power Switch Grounding
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
Chapter 2 Installation Guide
Please use caution when operating this device in order to abstain any possible injury during installation.
For this reason, please read all details listed below and make and use caution before proceeding to
operate and use this electronic equipment.
2.1 General Precautions
Must be operated and maintained free of dust or debris. The cover should be securely fastened, do not open the cover of the products when the power
is on.
After installation, securely stow away all loose cables, external antenna, and others.
2.2 Power Precautions
When you connect the power source, make sure it is grounded correctly so it doesn’t cause an
overload.
Avoid operating on a wet floor in the open. Make sure the extension cable is in good
condition.
Make sure the power switch is off before you start to install the device.
2.3 Device’s Installation Flow Chart Illustrated as following
Connecting
Grouding Wire and
Power
Cord
Acquisition
Check
Installing
Device
Setting
Parameter
Running
Device
Connecting
Signal
cable
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
2.4 Environment Requirement
Item
Requirement
Machine Hall Space
When user installs machine frame array in one machine hall, the distance between 2 rows of machine frames should be
1.2~1.5m and the distance against wall should be no less than
0.8m.
Machine Hall Floor
Electric Isolation, Dust Free Volume resistivity of ground anti-static material:
1X107~1X1010,Grounding current limiting resistance: 1M
(Floor bearing should be greater than 450Kg/)
Environment Temperature
5~40(sustainable )0~45(short time) installing air-conditioning is recommended
Relative Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door & Window
Installing rubber strip for sealing door-gaps and dual level glasses for window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting power are independent to each other. Device power requires AC 110V±10%, 50/60Hz or AC 220V±10%, 50/60Hz. Please carefully check before running.
H-4HD-EMS & EMH
Thor Fiber 2017 Tel: (800) 521-8467 Email: sales@thorfiber.com www.thorbroadcast.com
2.5 Grounding Requirement
It is important to keep this device grounded to ensure all of the modules
function correctly. Correctly grounding the device will also help prevent any electrical interference, lightening. Etc. Also it helps reject minor interference that may disrupt the devices ability to function smoothly. General rule of them, make sure the device is grounded when installing anywhere.
Always use copper wire. When applied correctly the ground must be wrapped
well to ensure maximum conduction so it can reduce any high frequencies. The copper ground wire should also be as short and thick as possible
Installer must make sure that the two ends of the ground are well conducted
and have appropriate anti-rust properties.
It is prohibited to use any other device as part of the grounding electric
circuit.
The area of the conduction between the ground wire and device’s frame
should be no less than 25 .
Loading...
+ 23 hidden pages