Thomson LDK 4482 User Manual

LDK 4482LDK 4482
LDK 4482
LDK 4482LDK 4482
SuperXpander
User’s Guide
3922 496 48661 St.01
Declaration of Conformity
We, Thomson Broadcast Solutions Nederland B.V., Kapittelweg 10, 4827 HG Breda, The Netherlands declare under our sole responsibility that this product is in compliance with the following standards: EN60065 EN55103-1 EN55103-2 following the provisions of: a. the Safety Directives 73/23//EEC and 93/68/EEC b. the EMC Directives 89/336/EEC and 93/68/EEC
: Safety : EMC (Emission) : EMC (Immunity)
FCC Class A Statement
This product generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause interference to radio communications. It has been tested and found to comply with the limits for a class A computing device pursuant to Subpart J of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a com­mercial environment. Operation of this product in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.
Copyright
Für diese Unterlage behalten wir uns alle Rechte vor (Gemäß DIN 34). Technische Änderungen im Zuge der Weiterentwicklung vorbehalten.
© Thomson Multimedia Broadcast Solutions 2002
Copying of this document and giving it to others, and the use or com­munication of the contents thereof, are forbidden without express au­thority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Liable to technical alterations in the course of further development.
Toute communication ou reproduc­tion de ce document, toute ex­ploitation ou communication de son contenu sont interdites, sauf au­torisation expresse. Tout man­quement à cette règle est illicite et expose son auteur au versement de dommages et intérêts. Tous nos droits sont réservés pour le cas de la délivrance d'un modèle d'utilité. Sous réserve de modification au cours de l'évolution technique.
LDK 4482
SuperXpander
User's Guide
Contents
Location of Controls and Functions ................... 1-2
Location of Controls and Functions for HS ........1-4
02.38.3 User's Guide LDK 4482 - SuperXpander 1-1
Connections..................................................... 1-10
Service Information .......................................... 1-14
Location of Controls and Functions
Rear Panel
4321
10
5
9876
FILTER
0
1(CLR)
0
2
0
3
Optical filter selection
1
0
4
0
5
0
6
MSC. SIGN
0
0
0
Pip
Auto
white
VF
Boost
Camera on Remote Heater
On air
Select the optical filter by touching the appropriate numbered switch. Switch 1 : Clear filter
Switch 2 : ND 0.6 filter Switch 3 : ND 1.2 filter Switch 4 : ND 1.8 filter Switch 5 : 4 Point Star filter
Switch 6 : 6 Point Star filter The LED in the switch flashes during a change and then lights continuously to indicate the selected filter. (The operation of this switch depends on the user level that has been set for the camera.)
VIEWFINDER
0
0
Select
0
0
0
0
0
Centre
R
G
B
cross
0
zone
0
Focus
Safe
ind
0
0
0
Ext 1
Ext 2
Y/ext
0
0
0
Lamp
off
Dimm
Call
camera is in the local control mode.
LED indicators
4
CAMERA ON : lights when the camera is receiving
power.
REMOTE : lights when the camera is in the
remote control mode. HEATER : lights when the lens heater is on. ON AIR : the red LED lights when the camera
is on air.
: the yellow LED lights when the ISO
signal is activated.
5
Automatic white balance switch
2
Pressing this switch starts the automatic white balance process. This switch is in parallel with the AWB switch at the front/left of the camera and operates in the same way. The LED in the switch flashes during the auto-white process. (The operation of this switch depends on the
Viewfinder R, G and B switches
Switches the R, G or B signal from the camera for display in the viewfinder. When an R, G or B switch is deselected, the Y or Y + c signal is displayed. The selection of the Y or Y+c (contours added) signal is carried out in the Vf/Lens \ Vf Inst \ Vf mon menu on camera.
user level that has been set for the camera.)
3
VTR switch
When pressed it starts or stops the VTR when the
1-2 User's Guide LDK 4482 - SuperXpander 02.38.3
10
4321
5
9876
FILTER
0
1(CLR)
0
0
Viewfinder indicators switch
6
0
4
0
2
3
5
0
6
MSC. SIGN
0
0
0
Pip
Auto
white
VF
Boost
Camera on Remote Heater
On air
Switches the centre cross, safe area and focus indicators in the viewfinder on and off.
7 Viewfinder EXT1, EXT2 and
Y switches
Switches the Ext 1 and Ext 2 signal for display in the viewfinder. Ext 1 and Ext 2 are also selectable with the pan-bar switches. Y/ext on switches a mix of Y and Ext 1 or Ext 2 signal for display in the viewfinder. Y/ext off switches only Ext 1 or Ext 2 signal for display in the viewfinder. If no switch is selected the previous signal is displayed (R, G, B, Y or Y+c).
VIEWFINDER
0
0
Select
0
0
0
0
0
Centre
R
G
B
cross
0
zone
0
Focus
Safe
ind
0
0
0
Ext 1
Ext 2
Y/ext
0
0
0
Lamp
off
Dimm
Call
The Y or Y+c (contours added) signal is selected in the Vf/Lens \ Vf Inst \ Vf mon menu on the camera. Note: Viewfinder and External selection switches on the camera are disabled.
8 Dim
Switches the brightness of the on-air lamp on the viewfinder up and down in steps.
On air lamp switch
9
If function On air is on you can switch the on air lamp on the lens and 7-inch viewfinder on and off.
Note:
For function On air see Installation Manual Base Station.
10
Call switch
Pressing this switch sends a signal to the control panels calling for attention. An incoming call activates the LED in the switch.
02.38.3 User's Guide LDK 4482 - SuperXpander 1-3
Loading...
+ 11 hidden pages