THOMSON HD 200, HD 400, HD 450, HD 500, HD 550, HD 600, HD 650, HD 300, HD 750, HD 700, HD 800, HD 850, HD 900, HD 950, HD 1000 Installation Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Thomson Electrak® HD
Electric Linear Actuator
Installation Manual
Edition 2016-01
P-264-HD
www.thomsonlinear.com
Thomson
Version history
EditionReason for revision
2016-01First edition
Warranty
The Thomson Electrak® HD is warranted to be free from defects in materials and workmanship for a
period of twelve (12) months from date of delivery. The application of this product is the responsibility
of the buyer and Thomson makes no representation or warranty as to the suitability of the product for
any particular use or purpose. For a copy of the entire warranty for this product that is contained in our
standard terms and conditions of sale, please go to http://www.thomsonlinear.com/website/com/
eng/support/terms_and_conditions.php.
Disclaimer
Technical changes to improve the performance of the equipment may be made without prior notice!
All rights reserved. No part of this work may be reproduced in any form (by printing, photocopying,
microlm or any other method) or processed, copied or distributed by electronic means without the
written permission of Thomson.
Thomson Electrak® HD Actuator - Installation Manual - 2016-012
Contents
Thomson
Contents
1. General ...................................................................................................... 4
1.1 About this manual .................................................................................................. 4
1.2 Target group ........................................................................................................... 4
1.3 Symbols used ........................................................................................................ 4
1.4 Transport and storage ............................................................................................ 4
Thomson Electrak® HD Actuator - Installation Manual - 2016-013
Thomson
General
1. General
1.1 About this manual
This manual contains mechanical and electrical installation instructions for the Thomson Electrak® HD
electric linear actuator. It also contains, among other things:
• technical data
• installation data
• type designation key.
It is important to carefully read this manual before installing the actuator and to have the correct
qualications needed to perform the installation.
1.2 Target group
This manual addresses qualied mechanical and electrical personnel.
1.3 Symbols used
This symbol is shown to highlight a general warning, general instruction or as a warning for a
mechanical hazard.
1.4 Transport and storage
The actuator may only be transported and stored in the original packaging supplied by Thomson. The
temperature during transportation and storage must be between -40 to +85° C(-40 to +185° F). Avoid
shocks to the package. If the package is damaged, check the actuator for visible damage and notify the
carrier, and if appropriate also Thomson.
1.5 Packaging
The packaging consists of a cardboard box. The box contains the actuator and this manual. For large
quantity orders bulk packaging may be used in which case the packaging and the content will vary
depending on the order agreement.
1.6 Disposal
Where required by law, used packaging and actuators are taken back by Thomson for professional
disposal if the transportation cost is paid by the sender. Please contact Thomson for shipping information.
1.7 Support
If technical support or information is needed for this product, please contact the nearest Thomson
Service Center. See the back of this manual. You can also visit www.thomsonlinear.com for information
on this product and how to contact us.
Thomson Electrak® HD Actuator - Installation Manual - 2016-014
Safety and Standards
Thomson
2. Safety
2.1 Safety notes
• Only properly qualied personnel are permitted to perform mechanical and electrical installation of this product. Properly qualied personnel are familiar with mechanical or electrical
installation work and have the appropriate qualications for their job.
• Read this manual and any other available documentation before working on the equipment
that the actuator is or shall be a part of.
• Conform strictly to the information contained in this manual and on the actuator product label
on the actuator. Never exceed the performance limits stated herein.
• Never work on the actuator or its installation with the power on.
• Never unplug any cables or connectors during operation or with power on.
• Immediately stop using the actuator if it seems faulty or damaged in any way and notify an
appropriate person so that corrective actions can be taken.
• Never open the actuator as that will compromise the sealing and the function of the
actuator. There are no serviceable components inside.
• Grease may be present on the extension tube. Contact is non-hazardous. Film should not be
removed.
3. Standards
3.1 EC Declaration of incorporation of partly completed machinery
We, Thomson Linear
declare that this product corresponds with the International Standard ISO 13766:2006-05 2nd Edition
(Earth Moving Machinery, Electromagnetic Compatibility). The directive (MD) 2006/42/EC annex 2.1.B,
RoHSII directive 2011/65/EU, and that the standard EN ISO 12100:2010, Safety of machinery, have been
applied.
Thomson Electrak® HD Linear Actuator HDxxBxxx-xxxxxxxxxxx
Product Description
Can be used when the machine or the system, which it shall be, a part of is in accordance with the
demands in the EEC Machinery Directive and/or other relevant regulations.
Håkan Persson Business Unit Manager Name Title Signature
Thomson Electrak® HD Actuator - Installation Manual - 2016-015
Kristianstad 2016-02-16
Date
Thomson
Installation
4. Installation
4.1 Product label
The product label can be found on the side of the cover tube. It will tell you which model of actuator
you have, its basic performance data and where it is manufactured. Please study the product label
to determine actuator type before starting any installation or service on the actuator. If you need any
assistance from Thomson, please provide the serial number, manufacturing date and the designation of
the actuator(s) in question. You can also use the QR code on the label to directly access Electrak HD
information on www.thomsonlinear.com.
4.2 Terminology
a. power cableb. signal cablec. housing
d. manual override inpute. cable connector cover platef. cover tube
g. extension tubeh. rear adapteri. product label
j. limit switch slotsk. front adapter
4.3 Operation environment
Min. -40° C (-40° F) Max. +85° C (+185° F) IP67 / IP69K
1. Operation temperature range is -40 to +85° Celsius (-40 to +185° Fahrenheit).
2. Protection degree against the ingress of water and particles is IP67 / IP69K.
3. Relative humidity range is 10 - 90 % non-condensing.
Thomson Electrak® HD Actuator - Installation Manual - 2016-016
Installation
Thomson
4.4 Mechanical installation
4.4.1 General installation safety notes
• Never work on the actuator with the power switched on!
• Do not hold the extension tube while the unit is energized.
• Failure modes of the actuator should be considered to ensure it does not create harm.
4.4.2 Basic installation considerations
1. Only mount the actuator using the holes in the rear (a) and front (b) adapters. Check the model
number on the actuator product label (section 4.1) and then look at the ordering key (section 6.2)
to nd out your adapter type conguration. See the below drawings and table to nd out the exact
adapter dimensions.
2. Make sure that the actuator mounting position allows access to the cable connector cover plate (c), so
that it can be removed to allow access to the cable connector(s) (section 4.4.4).
3. The cable or cables (d) exit the cable slot at the rear of the actuator housing at delivery but can be
made to leave the housing at any point after the cable connector cover plate.
4. The manual override input (e) must have enough free space around it to allow it to be operated
(section 4.4.5).
5. If external limit switches will be used, the mounting of the actuator must allow access to the limit
switch slots (f) running along the underside of the cover tube (section 4.4.6).
Thomson Electrak® HD Actuator - Installation Manual - 2016-017
Adapter type
Thomson
4.4.3 Mounting orientation and forces
1. The actuator can be mounted in any orientation and handle both pushing and pulling loads.
2. Always install actuator so that the force of the load acts in the center of the extension tube and the
rear adapter.
3. Only mount the actuator to the rear and front adapter mounting holes.
4. Only use solid mounting pins and support them at both ends.
5. The mounting pins must be parallel to each other both radially and axially.
YESNO
4.4.4 Cable connector cover plate
1. The cover plate is held in place by a screw (M3 with Torx T10 head) that can be accessed through
the hole in the top of the cover plate (a). Keep in mind to mount the actuator so that there is enough
clearance to access the screw with a tool!
2. Once the cover plate is released it needs to be pushed about 20 mm (0.8 inch) in the direction of
the arrow symbol on the cover plate before it can be removed from the actuator (b). The connectors
are a part of the backside of the cover plate and can be accessed once the cover plate is removed.
3. Make sure to put the cover plate back correctly and torque the screw to 1.2Nm (10.6 in-lb) to ensure
that the actuator cover plate and connectors are properly sealed.