Thomas & Betts Steel City RPT6 Series, Steel City RPT6-CVR-ALM, Steel City RPT6-CVR-BRS, Steel City RPT6-CVR-BLK Installation Instructions Manual

Installation Instructions
Catalog Numbers: RPT6-CVR-ALM, RPT6-CVR-BRS, RPT6-CVR-BLK
WARNING
RISK OF SHOCK, DISCONNECT POWER
BEFORE INSTALLATION.
IMPORTANT: Read all instructions before installing poke-through or cover.
NOTE: This cover is used with a RPT6 Series
Poke-Through. THIS COVER CAN BE OPENED WITH OUT TOOLS.
Installation Materials Required:
• Ulility Knife to cut carpet.
• RTV Silicone Sealant to seal cover to oor (prevents water leakage)
• Phillips Screw Driver
Table of Contents:
1.0 Installation
2.0 Cover Operation
3.0 Template, Floor Cut Out
1.0 INSTALLATION
1.1 Remove PT6-AC Abandonment / Temporary Cover (if present) by unscrewing the (4) #6-32 X 1” long screws, exposing the top rim of the poke-through.
1.2 Install oor covering and trim hole around poke-through to 7-1/4” diameter. (See Figure 1 and Section 3.0 Template, Floor Cut Out).
1.3 Apply sealant to oor:
1.3.1 Concrete and Carpet: Apply moderate
1.3.2 Tile, Wood and Linoleum: Appy moderate
1.4 Install new RPT6-CVR-XXX cover. Remove lid from cover to expose (4) mounting holes. Orient cover so that latch is on best side for application. Install the cover using the (4) #6-32 x 1” long screws, furnished with cover (See Figure 1).
1.5 After cover is screwed to poke-through, close lid (See 2.4) and push down on top to fully seat cover to oor. Clean excess sealant around cover edge. (See Figure 2).
amount of RTV silicone sealant directly to concrete oor fully around top rim of poke-through. Use enough sealant to block water entry. (See Figure 1).
amount of RTV silicone sealant directly to nished oor. Fully surround 7-1/4“ opening in oor. Use enough sealant to block water entry (See Figure 1).
CAUTION
Consult a qualified electrician in accordance with
National and Local Electrical Codes.
#6-32 x 1” Long Screws 4 places
PT6-AC Cover
Top Rim
Tile, Wood,
Carpet or
Linoleum
Figure 1
Figure 2
Latch
Apply Sealant to block water entry (see Step 1.3)
Close Lid and
Push Down
(See Step 2.4)
Removable Lid
RPT6-CVR-XXX
Cover
7-1/4” Dia Cut-out
Concrete
Clean excess Sealant around the cover edge.
TA04727 B Page 1 of 3
2.0 COVER OPERATION
2.1 Lid is spring loaded. Pull Lid Latch and Lid will open about 1/4” (See Fugure 3).
2.2 Lift Lid OFF Cover and rotate 180 degrees to allow cords to enter recessed poke-through. Lid is tethered to Cover to prevent loss. (See Figure 4).
2.3 Plug power or data cords into devices under Lid and route cords to exit on side of opening in Lid. (See Figure 6).
2.4
Close Lid. Insert (2) tabs on Lid side into recessed openings on Cover on side opposite of latch. (See Figure 5)
.
2.5 Fold Lid shut and press down to engage latch (See Figure 6). Be careful to allow cords to exit opening when Lid is oriented for power for power or data use.
Pull Latch
Figure 3
Tabs
Lid Latch
Lid Pops Up
Rotate Cover
180 Degrees
to allow cords
to enter
Thether
Figure 4
Power or Data Cords
Press Down
Slot (dash line)
Tabs
Figure 5
WARRANTY: Thomas & Betts sells this product with the understanding that the user will perform all necessary tests to determine the suitability of this product for
the user's intended application. Thomas & Betts warrants that this product will be free from defects in materials or workmanship for a period of two (2) years following the date of purchase. Upon prompt notication of any warranted defect, Thomas & Betts will, at its option, repair or replace the defective product. Misuse, misapplication or modication of Thomas & Betts Products immediately voids all warranties.
Limitations and Exclusions: THE ABOVE WARRANTY IS THE SOLE WARRANTY CONCERNING THIS PRODUCT, AND IS IN LIEU OF ALL OTHER
WARRANTIES EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE SPECIFICALLY DISCLAIMED. LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS LIMITED TO COST OF REPAIR OR REPLACEMENT OF THE PRODUCT, AND UNDER NO CIRCUMSTANCES WILL THOMAS & BETTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Figure 6
Power or Data Cords
Thomas & Betts Corporation
Memphis, Tennessee
www.tnb.com
© 2016 Thomas & Betts. All Rights Reserved.
TA04727 B Page 2 of 3