Operating Instructions
274FT(1)
Feed--Thru/Grounding Device
CONTENTS: Feed--thru body complete with mounting hardware, Lubricant, Operating Instructions.
A. A junction point. B. A grounding point.
To use the feed--thru as a junction point, follow steps 1 to 5 and 6A and 7A. To use the feed--thru as a grounding point, follow steps 1 to 5 and 6B to 9B.
A yellow band provides indication of full elbow seating and also provides vents for improved switching performance. This product is identified by a yellow ID washer attached to the eyebolt.
DANGER
All apparatus must be de--energized during installation or removal of part(s) except for test point caps and indicators that can be installed and operated energized.
After installation loadbreak products can be operated energized per operating instructions. All deadbreak connectors must be de--energized before operating.
All apparatus must be installed and operated in accordance with individual user, local, and national work rules. These instructions do not attempt to provide for every possible contingency.
Do not touch or move energized products.
“Loadbreak connectors must be operated with a full insulated “hotstick” type live -- line tool.” Consult the company’s safe work practices for the required live--line tool length.
FOR MORE INFORMATION ON PARTS, INSTALLATION RATINGS AND COMPATIBILITY, CALL THE NEAREST ELASTIMOLD OFFICE.
Excess distortion of the assembled product may result in its failure.
Inspect parts for damage, rating and compatibility with mating parts.
This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. These instructions are not intended as a substitute for adequate training or experience in such safety practices.
Failure to follow these instructions will result in damage to the product and serious or fatal injury.
If this product is supplied with a protective shipping cover(s), remove this shipping cover(s) and replace with the appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit.
IMPORTANT
1. Check contents of package to ensure they are complete and undamaged.
2. Check all components to ensure proper fit with cable and/or mating products.
STEP 1
Grounding-- Insert ground lead into the grounding lug provided on the mounting hardware and tighten lug. Ground lead should be No. 14 copper wire or equivalent. Connect the opposite end of the lead to ground, leaving enough slack to operate with a hotstick.
Yellow Seating Indicator and Vent Ring
IS---0797 IS---274FT(1)
January 2010 Printed in U.S.A.
8155 T&B Boulevard, Memphis, Tennessee 38125 (800) 888--0211 Fax: (800) 888-- 0690
3. Read entire installation instructions before starting.
4. Have all required tools at hand and maintain cleanliness throughout the procedure.
Yellow ID Washer
To Ground
Ground Lug
No. 14 Copper Wire
IS---0797
January 2010 Page 2 of 4
STEP 2
Remove the protective caps from the bushings of the feed--thru.
PROTECTIVE CAPS MUST NOT BE ON THE BUSHINGS OF THE FEED--THRU WHEN THE FEED--THRU IS BEING USED. When the feed--thru is not in use, the protective caps should be placed on the bushings of the feed--thru to protect them from dirt and other contaminants.
Clean the bushing surfaces and lubricate them with the lubricant supplied. DO NOT SUBSTITUTE. Other lubricants may be harmful to this product and its mating product(s).
Clean &
Lubricate
Clean &
Lubricate
STEP 3
Attach feed--thru eye firmly to hotstick. Eye
STEP 4
Using a hotstick, slide feed--thru onto parking stand. Unlock hotstick and back off, to allow space for eyebolt to be tightened. Tighten eyebolt by rotating hotstick clockwise until snug. DO NOT OVERTIGHTEN. Releasehotstick.
Parking
Strand
Hotstick
Eyebolt
Hotstick
To Ground
FRONT VIEW
Parking
Stand
SIDE VIEW