Thomas & Betts AFM-FAS-C-GRY, AFM-FAS-C-BLK Installation Manual

Page 1
ACCESS FLOOR MODULE COVER
Installation Instructions
Cat. Nos. AFM-FAS-C-BLK (black cover) and AFM-FAS-C-GRY (gray cover)
CAUTION
Read all Instructions before installing the AFM Cover.
INSTALLATION INSTRUCTIONS: (of Cover Flange and Access Cover)
STEP 1
Attach Cover Flange to the AFM-FAS Series Floor Box using the mounting screws (4 included).
STEP 2
Position the Access Cover over the opening in the Cover Flange and snap it into place. The Access Cover can be assembled to open in either direction.
ASSEMBLY
Pull Handle
Access Cover
WARNING
RISK OF SHOCK, DISCONNECT POWER BEFORE INSTALLATION.
1/4” USE SHIM KIT AFM-FAS-SHIMKIT AS FOLLOWS:
5/16” - 3/8” FLOOR THICKNESS, USE ONE SHIM KIT,
7/16” - 9/16”FLOOR THICKNESS, USE
1/2” - 5/8” FLOOR THICKNESS, USE
11/16 - 3/4” FLOOR THICKNESS, USE
13/16” - 7/8” FLOOR THICKNESS, USE
15/16” - 1” FLOOR THICKNESS, USE
PLACE SHIM(S) AS REQUIRED ON TOP OF BOTH DEVICE PLATES.
Mounting Screws (4 included)
(for Cover Flange)
TWO SHIM KITS
THREE SHIM KITS
FOUR SHIM KITS
FIVE SHIM KITS
SIX SHIM KITS
AFM-FAS Series Floor Box (Sold Separately)
Device Plate
FIG. A
Cover Flange
AFM-FAS-SHIMKIT Shim Supports
(As Required for thicker oor coverings )
Device Plate
TA04493 A Page 1 of 2
Page 2
MODES OF USE
Cover Flange
Access Cover
Cord Door
NOT IN USE
FIG. B
OPERATION of Access Cover
Access Cover
Pull Handle
Cord Door
Pull Handle
Access Cover
Cord Door
(Shown in Open position)
Power Cords
WHILE IN USE
Finger Slot
Access Cover:
Lift up on Pull Handle and Pull Upward to open Access Cover.
Cord Doors:
1) To open Cord Door, rotate underneath access cover.
2) To close Cord Door, grip the Door at the Finger Slot on both
FIG. C
REMOVAL of Access Cover
Open the Access Cover slightly and insert a Straight-blade
sides and rotate outward.
Access Cover
Cover Flange
Screwdriver as shown. Twist the at head screwdriver (as if turning a screw) until the hinge is free from the Cover Flange.
Use this method when you need to access the Mounting Screws to remove the Cover Flange or to switch the Access
FIG. D
WARRANTY: Thomas & Betts sells this product with the understanding that the user will perform all necessary tests to determine the suitability of this product for the user’s intended application. Thomas & Betts warrants that this product will be free from defects in materials and workmanship for a period of two (2) years following the date of purchase. Upon prompt notication of any warranted defect, Thomas & Betts will, at its option, repair or replace the defective product or refund the purchase price. Proof of purchase is required. Misuse or unauthorized modication of the product voids all warranties.
Limitations and Exclusions: THE ABOVE WARRANTY IS THE SOLE WARRANTY CONCERNING THIS PRODUCT, AND IS IN LIEU OF ALL OTHER WARRANTIES
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE SPECIFICALLY DISCLAIMED. LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS LIMITED TO COST OF REPAIR OR REPLACEMENT OF THE PRODUCT, AND UNDER NO CIRCUMSTANCES WILL THOMAS & BETTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Cover orientation.
Screwdriver Blade
© 2009 Thomas & Betts. All Rights Reserved.
Thomas & Betts Corporation
Memphis, Tennessee
www.tnb.com
TA04493 A Page 2 of 2