IMPORTANTSAFETYINSTRUCTION
Pleaseseebelowbasicprotectionproceedingbeforeusing
1.Pleasereadallthesafetyinstructionbeforeusingtheproduct.
2.Thisproductmustbeearthed.Ifitshouldbemalfunctionorbreakdown,groundingprovidesapathofleastresistancefor electriccurrenttoreduceriskofelectricshock.
Thisproductisequippedwithacordhavinganequipment-groundingconductorandagroundingplug.Theplugmustbe
pluggedintoanappropriateoutletthatisproperlyinstalledandearthedinaccordancewithalllocalcodesandordinance.
Improperconnectionoftheequipment-groundingconductorcanresultinariskofelectricshock.Checkwitha qualifiedelectricianorservicemanifyouareindoubtastowhethertheproductisproperlygrounded.Donotmodifytheplug providedwiththeproduct-ifitwillnotfittheoutlet,haveaproperoutletinstalledbyaqualifiedelectrician.
3.Toreducetheriskofinjury,closesupervisionisnecessarywhentheproductisusednearchildren.
4.Donotusethisproductnearwater-forexample,nearabathtub,washbowl,kitchensink,inwetbasementorneara swimmingpoolorthelake.
5.Thisproductmaybecapableofproducingsoundlevelsthatcloudcausepermanenthearingloss.Donotoperateforalong periodoftimeathighvolumeleveloratalevelthatisuncomfortable.Ifyouexperienceanyhearinglossorringingintheears, youshouldconsultanaudiologist.
6.Thisproductshouldbelocatedsothatitslocationorpositiondoesnotinterferewithitsproperventilation.
7.Thisproductshouldbelocatedawayfromheatsourcessuchasradiators,heatregistersorotherproductsthatproduceheat.
8.Theproductshouldbeconnectedtoapowersupplyonlyofthetypedescribedontheoperationinstructionsorasmarkedon theproduct.
9.Thisproductmaybeequippedwithapolarizedlineplug(onebladewiderthantheother).Thisisasafetyfeature.Ifyouare unabletoinserttheplugintotheoutlet,contactanelectriciantoreplaceyourobsoleteoutlet.Donotdefeatthesafetypurpose oftheplug.
10.Thepower-supplycordoftheproductshouldbeunpluggedfromtheoutletwhenleftunusedforalongperiodoftime. Whenunpluggingthepower-supplycord,donotpullonthecord,butgraspitbytheplug.
11.Careshouldbetakensothatobjectdonotfallandliquidarenotspilledintotheenclosurethroughopening.
12.Theproductshouldbeservicedbyqualifiedservicepersonnelwhen: A.Thepower-supplycordortheplughasbeendamaged;or B.Objectshavebeenfallen,orliquidhasbeenspilledintotheproduct;or C.Theproducthasbeenexposedtorain;or D.Theproductdoesnotappeartooperatenormallyorexhibitsamarkedchangeinperformance;or E.Theproducthasbeendroppedortheenclosuredamaged..
13.Donotattempttoservicetheproductbeyondthatdescribedintheuser-maintenanceinstructions.Allotherservicing
shouldbereferredtoqualifiedservicepersonnel.
DANGER-
14-WARNING Donotplaceobjectsontheproduct'spowercordorplaceitinapositionwhereanyonecouldtripover,
walkonorrollanythingoverit.Donotallowtheproducttorestonortobeinstalledoverpowercordsofanytype.Improper installationsofthistypecreatethepossibilityoffirehazardand/orpersonalinjury.
SAVETHESEINSTRUCTIONS
CAUTION
RISKOFELECTRICSHOCK
DONOTOPEN
Thelightningflashwitharrowheadsynbolwithinanequilateral triangleisintendedtoalerttheusertothepresenceof uninsulateddangerousvoltagewithintheproduct'senclosure, thatmaybeofsufficientmagnitudetoconstituteariskofelectric shocktopersons.
Theexclamationpointwithinanequilateraltriangleisintended toalerttheusertothepresenceofimportantoperationand maintenace(servicing)instructionintheliterature accompanyingtheappliance.
CAUTION:TOREDUCETHERISKOFELECTRIC
SHOCKDONOTREMOVECOVER(ORBACK)
NOUSER-SERVICEABLEPARTSINSIDE
REFERSERVICINGTOQUALIFIEDPERSONNEL
Page 3
thet.racksmodelDL2/918
◆∑△
24-bit,-AD/DA,48kHzsamplingrate
Stereoprocessor,delay,limit,noisegateindependentchannelcontrol
Maximaldelay2.7s/perchannel(delayunitsrepresentableinmilliseconds,meters,feet).
Noisegate:-66dB~-24dB,availablefordifferentworkenvironments.
Swithpowersupply:90V~250V,50/60Hz
Delayadjuststep:1msand100msselectable
2
Page 4
1,INPUTLEDinputlevelmeterforRight/LeftChannel
2,LCD:162charactersLCDwithbacklittodisplayfunctionsandoperatingstatus.
3,JOG-WHEEL:selectthesubmenuandadjusttheparametersvalue.
4,MENU:selectthedelayunitsanddelayadjuststep
5,DELAY:Delayoperatingbutton
6,BYPASS:Enableordisablethedelayfunction
7,CH-SEL:Toselectthechannel/controlMIDIfunction
8,NOISEGATE
9,LOCK
10,POWERSWITCH:Besuretopower-upbeforeyouramplifieristurnedonto avoidloudtransientswhichcoulddamageyourspeakersorannoyyouraudience.
x
FRONTPANEL
3
Page 5
7
1
6
6
3
3
2
2
4
5 5
1,ACRECEPTACLE:Plugthepowercordinhere
2,XLRANALOGOUTPUT-SOCKET
3,XLRANALOGINPUT-SOCKET
4,INPUTLEVELADJUST
5,TRSANALOGOUTPUT-SOCKET
6,TRSANALOGINPUT-SOCKET
7,RS232:RESERVED,NOTAVAILABLEFORUSERS
PleasenoteeachgroupofXLRandTRSsocketisparallelconnected.
REARPANEL
4
CAUTION
TOREDUCETHERISKOFFIRE
REPLACEONLYWITHTHE
SAMETYPE
90V-250VAC
50/60Hz
FUSE:T1A/250V
Page 6
:
LeftDELAYON
Dely620msa
Fig.1
1,DefaultLCDopendisplayasfig.1.Intheupperarea,thedisplayshowsthechannelLeftwillbeadjustedand delayfunctionison.Below,thedelaytimeisdisplayed.Turnjog-wheeldirectlytoadjustdelaytime.
2,Pressmenubutton,thedisplayasfig.2.Turnjog-wheeltoselectsubmenusasfollows,
Delayunitcount
Delaycoarse/finetune
→ →
Fig.2
:
LeftDELAYON
mSCount
"
Del
"
Pressmenubuttonagaintoconfirmtheselectedsubmenu,thenturnjog-wheeltoadjustthevalues. Delayunitcountselect:millisecond,meterandfoot; Delaycoarse/finetunestepselect:1msand100ms.
:
LeftDELAYON
Delay10mSec.
OPERATION
5
3,Pressthedelaybuttontogotodelaytimeadjustpagefromelsewhere,thenturn thejog-wheeltoadjustthedesireddelaytimeasfig.3.
Fig.3
4,Pressthebypassbuttontoshutoffthedelayfunction,thedisplayshowsDELAYOFFasfig.4.
""
Fig.4
:
LeftDELAYOFF
Delay:10mSec.
Page 7
5,PresstheCH-SELbutton,thedisplayshowsasfig.6,youcanadjustthedesiredchannelviathejog-wheel. Threeoptionsareavailable:Left,RightandChannel-link.
Fig.6
:LeftDELAYON
ChannelSelect.
.
6
Pressthebypassbuttonagain,restorethedelayfunction,thedisplayshowDELAYONasfig.5.
""
Fig.5
:
LeftDELAYON
Delay:10mSec.
6,PresstheNOISEGATEbuttoninordertoenterthenoisegatesubmenuON/OFF,selectONorOFFstatusvia jog-wheelasfig.7.
Fig.7
:
LeftDELAYON
NoiseGateOFF
PresstheNOISEGATEbuttonagain,enterthenoisegatethresholdvaluesetupoperationasfig.8,youcanadjust
thethresholdviajog-wheel,therangeis-66dB~-24dB.
Fig.8
:
LeftDELAYON
NoiseGate-39dB
7,HoldtheLOCKbuttonuntilthedisplayshowsLOCKON.Allfunctionsarelockedasfig.9.Inordertounlock, presstheLOCKbuttonthenlDELAYONappearsinthedisplayasfig.8.
Fig.9
:
LeftLOCKON
NoiseGate-39dB
Page 8
ANALOGINPUT ReceptacleXLRand1/4jack TypeBalancedinput ImpedanceBalanced:40kohm;Unbalanced:20kohm Inputlevel-20dB~+4dB
ANALOGOUTPUT ReceptacleXLRand1/4jack TypeElectronicbalancedoutput ImpedanceBalanced:66ohm;Unbalanced:33ohm
SYSTEMSPECIFICATION Frequencyresponse20Hz~20kHz,1dB Dynamicrange>110dB,20Hz~20kHz S/Nratio>95dB,20Hz~20kHz Distortion<0.01%,@1kHz,0dB
±
DIGITALHANDLEPOWER AD/DA24bit­Samplingrate48kHz Display2x16characterLCDwithbacklit
Powersupply90V~250V,50/60Hz FuseT1A/250V Powerconsumption10W PowerplugstandardIECreceptacle Dimension(WxDxH)45mmX482mmX152mm Weight3kg
∑△
7