thomann the t. amp TA 450 MK-X, the t. amp TA 600 MK-X, the t. amp TA 1050 MK-X, the t. amp TA 1400 MK-X, the t. amp TA 2400 MK-X User Manual

Page 1
TA 450 MK-X
TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
power amplifier
user manual
Page 2
Musikhaus Thomann e. K. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
14.08.2012
Page 3
Table of contents
1 General notes............................................................................................................................................... 4
2 Safety instructions..................................................................................................................................... 7
3 Features....................................................................................................................................................... 12
4 Installation and starting up................................................................................................................ 13
4.1 Pin assignment.................................................................................................................................. 13
5 Connections and operating elements........................................................................................... 17
6 Technical specifications....................................................................................................................... 22
7 Protecting the environment.............................................................................................................. 25
Table of contents
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
3
Page 4
1
General notes
This user manual contains important information on safe operation of the device. Read and follow all safety notes and all instructions. Save this manual for future reference. Make sure that it is available to all persons using this device. If you sell the device, include the manual for the next owner.
Our products are subject to a process of continuous development. We therefore reserve the right to make changes without notice.
This section provides an overview of the symbols and signal words used in this user manual.Symbols and signal words
General notes
power amplifier
4
Page 5
Signal word Meaning DANGER! This combination of symbol and signal word
indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided.
CAUTION! This combination of symbol and signal word
indicates a possible dangerous situation that can result in minor injury if it is not avoided.
NOTICE! This combination of symbol and signal word
indicates a possible dangerous situation that can result in material and environmental damage if it is not avoided.
Warning signs Type of danger
Warning – high-voltage.
General notes
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
5
Page 6
Warning signs Type of danger
Warning – danger zone.
General notes
power amplifier
6
Page 7
2
Safety instructions
This device amplifies electric audio frequency signals to operate passive speakers. Use the device only as described in this user manual. Any other use or use under other operating con‐ ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
DANGER! Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
Intended use
Safety
Safety instructions
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
7
Page 8
DANGER! Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never remove any covers.
There are no user-serviceable parts inside.
DANGER! Electric shock caused by short-circuit
Always use proper ready-made insulated mains cabling (power cord) with a pro‐ tective contact plug. Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a regis‐ tered electrician.
Safety instructions
power amplifier
8
Page 9
CAUTION! Possible hearing damage
The device can produce volume levels that may cause temporary or permanent hearing impairment. Over an extended period of time, even levels that seem to be uncritical can cause hearing damage.
Decrease the volume level immediately if you experience ringing in your ears or hearing impairment. If this is not possible, keep a greater distance or use suffi‐ cient ear protectors.
CAUTION! Risk of injury due to heavy weight
Due to the heavy weight of the device, at least two persons are required for trans‐ port and installation.
Safety instructions
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
9
Page 10
NOTICE! Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames.
NOTICE! Operating conditions
This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations.
Safety instructions
power amplifier
10
Page 11
NOTICE! Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire.
NOTICE! Magnetic fields
The device generates strong magnetic fields that can interfere with the function of poorly shielded devices. The strongest magnetic fields are directly above and below the power amplifier. Therefore, never place sensitive devices such as pre­amplifiers, radio transmission systems, or tape decks directly above or below the power amplifier. When installing the power amplifier into a rack, you should place it in the lowest position, and further equipment such as pre-amplifiers in the highest position.
Safety instructions
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
11
Page 12
3
Features
n Inputs
2 × XLR – 2 × 1/4" phone sockets
n Outputs
2 × NL4 (lockable) – 2 × screw terminals
n Protection circuits
Audio limiter – Thermal protection – Short circuit protection – DC protection – Overcurrent – Subsonic noise protection
n Cooling via integrated two-stage fans n Suitable for 19" racks (2 RU, installation depth 44 cm)
Features
power amplifier
12
Page 13
4
Installation and starting up
Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the device against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
Establish all connections as long as the unit is switched off. Use the shortest possible high­quality cables for all connections.
4.1
Pin assignment
You can use XLR and 1/4" plugs with balanced or unbalanced wiring. In the following, we will give you an overview of the various options
Installation and starting up
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
13
Page 14
Balanced XLR mounting sockets serve as signal inputs. The following drawings and tables indi‐ cate the XLR pin assignment.
Balanced wiring:
1 Ground, shielding 2 Positive signal (+) 3 Negative signal (–)
Unbalanced wiring:
1 Ground, shielding 2 Signal 3 Bridged to pin 1
XLR connections for signal inputs
Installation and starting up
power amplifier
14
Page 15
The TRS inputs of the amplifier are only suitable for mono operation. The following drawings and tables indicate the pin assignment of a 1/4" phone plug to be used.
Balanced wiring:
1 (Tip) Positive signal (+) 2 (Ring) Negative signal (–) 3 (Sleeve) Ground, shielding
Unbalanced wiring:
1 Signal 2, 3 Ground, shielding
1/4" phone sockets for signal inputs
Installation and starting up
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
15
Page 16
The drawing alongside shows the pin assignment of the lockable NL4 mounting connectors.NL4 mounting connectors
Installation and starting up
power amplifier
16
Page 17
5
Connections and operating elements
Front panel
Connections and operating elements
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
17
Page 18
1 POWER
Main switch to turn the device on or off.
2 CH-A/B
Input gain control for the channels CH-A and CH-B.
3 LED indicators for channels CH-A/B
These LEDs indicate operational readiness of the unit (Power), the input signal level (Signal), overloading (Clip) and fault condition (Fault) an.
During operation, the Power LED lights up constantly. The Signal LEDs respond to the input signal. If one of these LEDs lights up without an input signal is present, dis‐ connect the speakers from the amp and turn the input gain control of both channels down to minimum. If the LEDs continue to light up, the device must be inspected by an authorized service centre.
Connections and operating elements
power amplifier
18
Page 19
Rear panel
Connections and operating elements
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
19
Page 20
4 Fuse holder. 5 OUT A | OUT B
Lockable NL4 mounting connectors for signal outputs to connect speakers.
6 OUT A | OUT B
Screw terminals (+/–) for signal outputs to connect speakers.
7 IN A | IN B
XLR mounting connectors for signal inputs.
8 IN A | IN B
1/4" phone sockets for signal inputs.
9 STEREO | PARALLEL | BRIDGED switch
Switch to select the operating modes ‘STEREO’ (both channels operate independently of each other), ‘PARALLEL’ (the inputs of both channel are interconnected) and ‘BRIDGED’ (both channels are interconnected to form one channel with double output power).
Connections and operating elements
power amplifier
20
Page 21
10 Lift | Ground switch
Use the Ground / Lift switch to separate the connection between the earth pin of the device and the signal ground in the unit. This prevents ground loops (position ‘Lift’ [switch is not pressed]: no connection. Position ‘Ground’ [switch is pressed]: earth pin and signal ground are electrically connected).
11 IEC chassis connector for operating voltage supply.
Connections and operating elements
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
21
Page 22
6
Technical specifications
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
Power consumption 5 A 6 A 7 A 8 A 15 A Output power
RMS
8 W,
stereo
2 × 125 W 2 × 200 W 2 × 350 W 2 × 450 W 2 × 650 W
Output power
RMS
4 W,
stereo
2 × 200 W 2 × 300 W 2 × 525 W 2 × 700 W 2 × 1200 W
Output power
RMS
8 W,
mono bridged
300 W 450 W 800 W 1200 W 2000 W
THD 4 W @ 1 kHz < 0.05 % / 200 W < 0.05 % / 300 W < 0.05 % / 525 W < 0.05 % / 700 W < 0.05 % / 1200 W IMD-SMPTE (60 Hz, 7 kHz)
< 0.01 % / 125 W < 0.01 % / 200 W < 0.01 % / 350 W < 0.01 % / 450 W < 0,01 % / 650 W
Damping factor (8 W, 1 kHz)
300:1 350:1 500:1
Voltage gain 50 × standard 70 × standard 91 × standard
Technical specifications
power amplifier
22
Page 23
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
Slew rate
40 V/ms 60 V/ms
Common mode rejection
> 60 dB (1 kHz)
Frequency response
20 Hz … 20 kHz (+ 0.1 …– 3 dB, 1 W, 8 W)
Input sensitivity
0.775 V @ rated power (8 W)
Input impedance
20 kW (balanced)
10 kW (unbalanced) Signal-to-noise ratio 103 dB Crosstalk
< 60 dB Protective circuits DC, thermal, short circuit, subsonic noise and overcurrent protection Cooling two controlled DC voltage fans Operating supply voltage
AC 230 V , 50/60 Hz
Technical specifications
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
23
Page 24
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
Dimensions (W × H × D) 483 mm × 103 mm
× 475 mm
485 mm × 103 mm × 470 mm
483 mm × 103 mm × 475 mm
Weight 13.3 kg 13.7 kg 16.4 kg 17.5 kg 19.7 kg
Technical specifications
power amplifier
24
Page 25
7
Protecting the environment
For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that
they are collected for recycling. Please follow the notes and markings on the packaging.
This device is subject to the European directive 2002/96/EC. Do not dispose of the device with your normal household waste. Dispose of this device through an approved waste disposal firm or through your local waste
facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility.
Disposal of the packaging mate‐ rial
Disposal of your old device
Protecting the environment
TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X
25
Page 26
Notes
power amplifier
26
Page 27
Page 28
Musikhaus Thomann e.K. · Treppendorf 30 · 96138 Burgebrach · Germany · www.thomann.de